• Title/Summary/Keyword: spectrum analyzer

Search Result 259, Processing Time 0.025 seconds

A Basic Study on the Improvement of Leakage Error of the Acoustic Intensity (음향 인텐시티의 누설오차 개선에 관한 기초적 연구)

  • 정의봉;정호경;안세진;윤상돈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.345-350
    • /
    • 2003
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidably have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed data of a harmonic signal with a single frequency is formulated when there is leakage error. The method to eliminate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

Development of Radio Spectrum Monitor for HF Communication (단파 스펙트럼 수신 모니터링 시스템 개발)

  • Park, Sung Won;Kim, Young Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.821-827
    • /
    • 2015
  • Electromagnetic waves which are emitted from the Sun due to solar flare explosion can cause failures in HF radio communications in the day-side area of the Earth, that is so-call as Radio Blackouts. The international scale representing the severity of the Radio Blackouts is determined by the solar X-ray flux which is measured by United States Geostationary Operational Environmental Satellite. However, the scale is not always applicable to HF communication users in the different area on the Earth, because the HF communication effects depend not only on the X-ray strength but also on the subsolar point location. To solve this problem, we developed a HF radio spectrum monitoring system utilizing a spectrum analyzer. This system conducts a real-time measure of the HF spectrum, and automatically calculates signal to noise ratios and the occurrences of the HF blackouts as comparing with the interference level which is described from the ITU recommendation.

Background Removal from XRF Spectrum using the Interval Partitioning and Classifying (구간 분할과 영역 분류를 이용한 XRF 스펙트럼의 백그라운드 제거)

  • Yang, Sanghoon;Lee, Jaehwan;Yoon, Sook;Park, Dong Sun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.164-171
    • /
    • 2013
  • XRF spectrum data of a material include a lot of background signals which are not related to its components. Since an XRF analyzer analyzes components and concentrations of an analyte using the locations and magnitudes of gaussian-shaped peaks extracted from a spectrum, its background signals need to be removed completely from the spectrum for the accurate analysis. Morphology-based method, SNIP-based method and thresholding-based method have been used to remove background signals. In the paper, a background removal method, an improved version of an interval-thresholding-based method, is proposed. The proposed method consists of interval partitioning, interval classifying, and background estimation. Experimental results show that the proposed method has better performance on background removal from the spectrum than the existing methods, morphology-based method and SNIP-based method.

A Study on the Measurement System Design for the Resin Flow and Curing in the Vacuum Assisted Resin Transfer Molding(VARTM) Process Using the Long Period Fiber Bragg Grating (삽입된 장주기 광섬유 격자를 이용한 VARTM 공정에서의 수지이동 및 변형 과정 예측 시스템 설계에 관한 연구)

  • Yoon, Young-Ki;Chung, Seung-Hwan;Lee, Woo-Il;Lee, Byoung-Ho;Byun, Joon-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.489-494
    • /
    • 2004
  • Long Period Gratings (LPG) is currently receiving considerable attention because of their consistent measuring results fur pressure, temperature, strain and flow. LPG is easier to prepare and has a high sensitivity compared with Fiber Bragg Gratings (FBG). In addition, this kind of optical fiber sensors could be used for implementations in various structures. In this paper, LPG was used to monitor in situ the resin flow and the curing process in VARTM (Vacuum Assisted Resin Transfer. Molding). In order to demonstrate the effectiveness of the method, FBG is inserted into the glass mat to monitor the resin flow using optical spectrum analyzer (OSA). The curing reactions in VARTM are also observed using the same method. From the results, the attenuation wavelength shift and the loss change of attenuation band can be obtained from the status of the RTM (Resin Transfer Molding) sample owing to the internal variations of the .effective index, temperature, and pressure. It is shown that the proposed LPG is more effective in monitoring the curing reaction than FBG.

Effect of Sn Contents on the Microstructure and Acoustic Characteristics of Cu-Sn Alloys (Cu-Sn합금의 미세조직 및 음향특성에 미치는 Sn함량의 영향)

  • Hong, Young-Keun;Lee, Jeong-Keun;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.21 no.2
    • /
    • pp.135-140
    • /
    • 2001
  • Microstructure of the bell made with Cu-Sn alloys was examined by optical and scanning electron microscope and that analyzed quantitatively with image analyzer. Also acoustic characteristics of the bells were measured in detail by using FFT type power spectrum analyzer. ${\alpha}-single$ phases of large grains only were observed in Cu-5%Sn alloy. However mixed structure of primary ${\alpha}-phase$ and eutectoid of ${\alpha}+{\delta}%_o$ was existed in the Cu-Sn alloys with more than 9%Sn. Also the area fraction of eutectoid phases gradually increased with an increased Sn content. From the result of acoustic test, it was found that frequency and tonal intensity decreased with the increased Sn content from 5%Sn to 11%Sn, and those were rather increased with further increase of that. The lowest frequency and tonal intensity were showed in Cu-11%Sn, and porosity decreased considerably frequency and tonal intensity of the bells.

  • PDF

Measurement of Ion Energy Distribution using QMS & Ionization Enhancement by usign Magnetic Field in Triod BARE (자장을 이용한 이온화율 증대형 삼극형 BARE에서 이온화율의 증대경향과 QMS를 이용한 이온의 에너지 분포 측정)

  • 김익현;주정훈;한봉희
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.3
    • /
    • pp.119-124
    • /
    • 1991
  • Recently, the trend of research in hard coating is concentrate on developing the process of ionization rate under low operating pressure, to get the thin film with high adhesion and dense microstructures. In this study ionization rate enhancement type PVD process using permanent magnet is developed, which enhances the ionization rate by confining the plasma suppressing the wall loss of electron. By the result to investigate the characteristic of glow discharge, the ionization rate of this process is enhanced about twice as high as that of triod BARE process (about 26%), and more dense TiN microstructures are obtained in this process. Cylindrical ion energy analyzer is made and attached in front of a quadrupole mass filter for the analysis of the energy distribution of reactive gas and activated gas ions from the plasma zone. To analyze the operation mechanism of ion energy analyzer, computer simulation is performed by calculation the electric field environment using finite element method. By these analyses of ion energy distribution of outcoming ions from the plasma zone, it is found that magnetic field enhances ion kinetic energy as well as ionization rate. The other results of this study is that the foundation of feed-back system is constructed, which automatically control the partial pressure of reactive gas. In can be possible by recording the data of mass spectrum and ion energy analysis using A-D converter.

  • PDF

A Design and Performance Investigation of VCO using Inductive Reactance Variation (유도성 리액턴스 변화를 이용한 VCO의 설계 및 동작 연구)

  • Oh, S.H.;Seo, S.T.;Koo, K.W.;Lee, Won-Hui;Hur, Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.405-408
    • /
    • 2000
  • We designed and fabricated VCO using inductive reactance variation at 2GHz. A varactor diode is one of the main devices in VCO, which varies capacitance depending on reverse voltage. In this paper, a varactor diode is not used as a variable capacitive reactance device but as an inductive device. The circuit design and simulation have been carried out using HP-MDS. The fabricated VCO is measured using the HP 8532B spectrum analyzer and the HP 4352B VCO/PLL analyzer. The experimental result shows the phase noise -110dBc/Hz at a 100kHz offset frequency, the control voltage sensitivity of 23MHz/V and a -3.5dBm output power with a D.C. current consumption of 5.9mA. The simulation and measurements show exact agreement except with regard to the oscillation frequency. The measured oscillation frequency is lower than the simulation result because there is some parasitic inductance in the PCB layout.

  • PDF

A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment (전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구)

  • Park, Gwang-Seo;Kim, Gi-Chae;Kim, Lee-Guk;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF

Infrared Thermographic Diagnosis Mechanism for Fault Detection of Ball Bearing under Dynamic Loading Conditions (동적 하중조건에서 볼 베어링의 고장 탐지에 대한 적외선 열화상 진단메커니즘 고찰)

  • Seo, Jin-Ju;Yoon, Han-Vit;Kim, Dong-Yeon;Hong, Dong-Pyo;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.134-138
    • /
    • 2011
  • Fault detection for dynamic loading conditions of rotational machineries was considered from the contactless, non-destructive infrared thermographic method, rather than the traditional diagnosis method. In this paper, by applying a rotating deep-grooved ball bearing, passive thermographic experiment was performed as an alternative way proceeding the traditional fault monitoring. In addition, the thermographic experiments were compared with the vibration spectrum analysis to evaluate the efficiency of the proposed method. Based on the results, it was concluded the temperature characteristics of the ball bearing under dynamic loading conditions were analyzed thoroughly.