• Title/Summary/Keyword: spectrophotometer

Search Result 1,496, Processing Time 0.03 seconds

Growth and Variance of Properties Er2O3 Doped Near Stoichiometric LiNbO3Single Crystals by the Czochralski Method (Czochralski법으로 Er2O3이 첨가된 Near Stoichiometric 조성 LiNbO3 단결정의 성장 및 특성변화)

  • ;;;Masayuki Habu;Takeshi Ito;Masakimi Natori
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.746-750
    • /
    • 2003
  • Using the Czochralski method, Er$_2$O$_3$ doped near stoichiometric LiNbO$_3$ single crystals were grown 15~20 mm in diameter and 30-35 mm in length for Z-axis. Lattice constants were inspected by the X-Ray Diffractometer (XRD) and through Fourier Transform-Infrared Spectrophotometer (FT-IR), it observed absorption band. Also, the distributions of Er concentration were confirmed by the Electron Probe Micro Analysis (EPMA).

A STUDY ON THE COLOR STABILITY OF PORCELAIN FOR PORCELAIN FUSED TO METAL CROWN (도재전장주조관에 사용되는 도재의 색안정성에 관한 연구)

  • Ryu, So-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.73-84
    • /
    • 2000
  • Dental porcelain should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental porcelain has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 types of porcelain(Vintage, VMK 95, CERAMCO II). The porcelain were divided into groups by 2 types of treatment(glazing or non-glazing and thermocycling or non-thermocycling). The porcelain were dyed with methylene blue and distilled water, and then the color stability was evaluated with a spectrophotometer The results were as follows; 1. The color change of porcelain increased in the order of VMK 95, Vintage, CERAMCO II. But there was no significant difference. 2. The color change decreased in the glazing group compared to the non-glazing group(p<0.05). 3. The color change increased after thermocycling But there was no significant difference. 4. The color change according to dye method was significantly larger with methylene blue copared to distilled water(p<0.05).

  • PDF

An evaluation on crystallization of amorphous (InTe)x(GeTe)y thin films by nano-pulse illumination (나노-펄스 노출에 따른 비정질(InTe)x(GeTe)y박막의 결정화 속도 평가)

  • Song, Ki-Ho;Seo, Jae-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.419-420
    • /
    • 2008
  • In this work, we report several experimental data capable of evaluating the phase transition characteristics of (InTe)x(GeTe)y (x = 0.1, 0.3, y =1) pseudo-binary thin films. (InTe)x(GeTe)y phase change thin films have been prepared by thermal evaporator. The crystallization characteristics of amorphous (InTe)x(GeTe)y thin films were investigated by using nano-pulse scanner with 658 nm laser diode (power : 1~17 mW, pulse duration : 10~460 ns) and XRD measurement. It was found that the crystalline speed of In-Ge-Te thin films are faster than $Ge_2Sb_2Te_5$[1] and also the crystalline temperature is higher. Changes in the optical transmittance of as-deposited and annealed films were measured using a UV-VIS-IR spectrophotometer and four-point probe was used to measure the sheeresistance of InGeTe films annealed at different temperature.

  • PDF

Comparison of the translucency of shaded zirconia all-ceramic systems

  • Kurtulmus-Yilmaz, Sevcan;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.415-422
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate and compare the translucency of shaded zirconia allceramic systems. MATERIALS AND METHODS. Translucency of 3 different zirconia all-ceramic systems colored by different techniques was compared with a lithium disilicate glass-ceramic (IPS e.max Press). Square-shaped specimens with 0.5 mm thickness were fabricated from In-Ceram YZ, ICE Zirkon and Katana systems in A1, A2 and A3.5 shades according to Vitapan Classical shade tab (n=11). Specimens were then veneered and glazed with corresponding veneer ceramic recommended by each zirconia system manufacturer and the total thickness was set to 1.5 mm. Translucency measurements were performed with VITA Easyshade Compact spectrophotometer after each stage and translucency parameter was calculated. Data were statistically analyzed with repeated measures ANOVA and Tukey multiple comparison test. RESULTS. The control group was significantly more translucent than the zirconia systems (P<.05). ICE Zirkon cores showed the least translucency; neither In-Ceram YZ nor Katana systems were superior to each other in terms of translucency. Translucency of all specimens was decreased after veneering, and the translucency rankings were changed. CONCLUSION. Coloring technique did not have a significant effect on translucency of zirconia cores. Although zirconia systems were less translucent than lithium disilicate glass ceramic, they had partial translucency and there were translucency differences among the zirconia systems. Chroma affected the translucency of precolored zirconia cores.

Studies on the Flavonoid Compositions of Korean Propolis (국산 프로폴리스의 플라보노이드 조성에 관한 연구)

  • 이수원;김희재;양희진;황보식
    • Food Science of Animal Resources
    • /
    • v.21 no.4
    • /
    • pp.389-394
    • /
    • 2001
  • This study was conducted to investigate the flavonoid contents of Korean propolis. The total flavonoids content measured by spectrophotometer of Yecheon, Youngwol, Brazilian, Chinese. Aus- tralian propolis were 6.33, 6.43, 2.44, 6.52 and 8.11mg/g. The p-coumaric acid content of Yecheon and Youngwol propolis were 5.58 and 6.84mg/100g, respectively. Luteolin, however, was not detected both in Yecheon and Youngwol, respectively. the quercetin content of Yecheon and Youngwol propolis revealed between 0.41 to 0.53%, however, overseas propolis was not detected. The t-cinnamic acid of Brazilian propolis was 7.92% and Chinese propolis was 8.74%. And than, the t-cinnamic acid of Chinese propolis was not detected.

  • PDF

Preparation and Properties of UV Curable Urethane Acrylates for Ink Binder (Ink Binder용 UV 경화형 조성물의 제조 및 특성)

  • Park, Hyun-Ju;Han, Chang-Duk;Oh, Sang-Taek
    • Journal of Adhesion and Interface
    • /
    • v.14 no.4
    • /
    • pp.167-174
    • /
    • 2013
  • In this study, Ultraviolet (UV) curable urethane acrylates for ink binder was prepared by reaction of IPDI, polyether polyol and HEA. The UV curing behavior of compositions with HEA/PETA ratio on UV irradiation time was investigated by FT-IR spectrophotometer, probe tack tester and Photo-DSC. Conversion % and gel content were increased with increasing UV irradiation time, but probe tack was decreased. Storage modulus, tensile strength and decomposition temperature were increased as PETA content increased. In case of HEA/PETA ratio was 30/70, adhesion property of UV-cured composition on PMMA sheet was excellent.

Effects of Gagam-Jawoonaek about Erythema by UV Exposure (가감자운액(加減紫雲液) 도포가 자외선으로 유발된 피부 홍반에 미치는 영향)

  • Kim, Tae Yeon;Kim, Yong Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.1
    • /
    • pp.94-101
    • /
    • 2014
  • We studied to investigate the erythema reduction effects generated by Gagam-Jawoonaek(GJ) application(appl.) after UV exposure. Twenty women in their twenties to fifties with no skin diseases were recruited. We exposed UV as a 6 subsites on the left upper arm of subjects using multi-port solar simulator. After setting Gagam-Jawoonaek(GJ) application(appl.) subsites and non-appl. subsites, we measured erythema degrees($a^*$ values) of the subsites using spectrophotometer. We measured $a^*$ values four times(before UV exposure, before application of GJ, twenty-four and forty-eight hours after first application of GJ). We analyzed data using student's t-test. After UV exposure, $a^*$ values on the left upper arm increased. Twenty-four hours after first GJ treat., the changes of $a^*$ value on GJ treat. subsites($1.22{\pm}0.13AU$) were bigger than GJ non-treat. subsites($1.04{\pm}0.12AU$), but there was no statistically significance. Forty-eight hours after first GJ treat., the changes of $a^*$ value on GJ treat. subsites($1.95{\pm}0.11AU$) were bigger than GJ non-treat. subsites($1.58{\pm}0.13AU$), a statistically significance. Gagam-Jawoonaek could decrease erythema by UV exposure.

The chemical effects of milking machine detergents on the rubber composition of the newly-developed teat cup liners (착유기 세척제가 신개발 젖소 유두컵 라이너용 고무조성물 재질에 미치는 화학적 영향)

  • Lee, Jeong-Chi
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.2
    • /
    • pp.125-131
    • /
    • 2018
  • This study investigated the effects of the alkaline detergent and acid rinse used for cleaning milking machines on the rubber composition of the newly-developed teat cup liners. The samples prepared for use in the clean-in-place process were analyzed by ultraviolet spectrophotometer, ion chromatography and liquid chromatography. In the absorption spectrum of the first sample solution, the form of absorbance or absorption peak was largely different, compared to the absorption spectrum of alkaline detergent alone, but in the absorption spectra of the second and third sample solutions, the absorbance decreased, which was similar to the absorption spectrum in the pure acid detergent. In the ion chromatogram, two main peaks only, which might be shown by the pure alkaline detergent alone, were measured. In the liquid chromatograms, however, new peaks were observed in addition to the two main peaks caused by the pure alkaline detergent alone, which suggested that various molecular materials were created or eluted from the liner by the reaction with the alkaline detergent, but when washed with the acid detergent, any ion species were not produced. Therefore, we propose that an acid rinse should be applied, after cleaning the milking machine with the alkaline detergent.

Measurment of Copper Concentration in ACQ, CUAZ, and CB-HDO Solutions by Using a Spectrophotometer

  • Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.450-456
    • /
    • 2010
  • This research was performed to develop the simple techniques to predict the copper concentration in alkaline copper quat (ACQ), copper azole (CUAZ), and bis-(N-cyclohexyl-diazeniumdioxy)-copper (CB-HDO) solutions. Two simple methods measuring the color due to copper compounds were evaluated by using a spectrophotometer. One is to directly measure the color of the preservative solutions. The other is to measure the color developed on the surface of a treated sample with the preservatives. The $L^*$ of the measured color values appeared to be the most sensitive to the change of copper concentration. The $a^*$ values of the preservative solutions tended to be decreased at above a certain concentration condition, and the $b^*$ values showed no trend with the concentration of copper compounds in preservative solutions. The surface color of the treated samples were changed from bluish to greenish as time passed. Both methods showed the high $R^2$ values of the regression models determined by using the lightness, which suggested that the methods might be applicable in preservative-treatment mills for the easy and fast prediction of the copper concentration.

Analysis on capacity loss caused by air oxidation of $V^{2+}$ ion using UV-Visible spectrophotometer for vanadium redox flow battery (공기 중 바나듐 2가 이온 산화에 의한 바나듐 레독스 흐름전지의 내구성 영향 분석)

  • Kwon, Soonkwan;Kim, Hansung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.175.2-175.2
    • /
    • 2011
  • 바나듐 3, 4, 5가 이온은 공기 중에서 안정하지만, 바나듐 2가 이온은 쉽게 산화된다. 그러므로 바나듐 2가 이온이 담겨져 있는 음극 탱크가 공기와 접촉하지 않게 하는 것이 중요하다. 충전 중 음극 탱크에 공기가 침투되면, 바나듐 2가 이온은 3가 이온으로 산화되기 때문에 음극과 양극의 전해질에 불균형을 초래한다. 이러한 불균형은 바나듐 레독스 흐름전지 용량저하의 원인이 된다. 본 연구에서는 공기 중 2가 이온 산화에 의한 전해질의 불균형 현상을 쉽게 보여주기 위해, 공기노출과 차단조건에서 충방전 중에 발생한 음극과 양극의 바나듐 이온 상태변화량을 UV-Visible spectrophotometer를 이용해 정량적으로 분석하였다. 분석 결과, 공기노출 조건에서 음극의 충전 시, 충방전 cycle이 진행 될수록 바나듐 2가 이온의 양이 현격히 줄어들었지만, 공기차단 조건에서는 2가 이온의 양이 공기노출 조건보다 훨씬 더 적게 줄어들었다. 즉, 공기차단 조건에서는 바나듐 2가 이온이 3가로 산화되지 않아서 음극의 충전 후 바나듐 3가에서 2가로 전환되는 양이 공기노출 조건보다 더 많은 것을 확인할 수 있었다. 이러한 영향으로 인해, 충방전 10th cycle을 진행해 본 결과, 공기차단 조건에서는 충방전 용량감소가 거의 없었지만 공기노출 조건에서는 현격한 충방전 용량 감소를 보였다.

  • PDF