• Title/Summary/Keyword: spectrometer

Search Result 2,555, Processing Time 0.053 seconds

Investigation of Heavy Metal Migration from Food Contact Materials used for Food Delivery Using an Inductively Coupled Plasma-Mass Spectrometer

  • Chae-Yeon Hwang;Young-Jun Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.2
    • /
    • pp.37-45
    • /
    • 2023
  • The surge in food delivery systems during the coronavirus 2019 pandemic necessitated this study of heavy metal migration from food contact materials (FCMs). A total of 104 samples of FCMs, comprising 51 polypropylene (PP), 21 polyethylene (PE), and 32 polystyrene (PS) samples of six different types of FCMs (containers, covers, table utensils, cups, pouches, and wrappers) used for food delivery distributed in Korea, were collected and investigated for migration of three heavy metals (Pb, Cd, and As) using inductively coupled plasma-mass spectrometry (ICP-MS) to determine whether they complied with Korea's Standards and Specifications for Utensils, Containers, and Packages. Acetic acid (4%, v/v) was used as the food simulant, and tests were performed at 100℃ (in harsh conditions) for 30 min. Linearity of Pb, Cd, and As showed acceptable results with a coefficient of determination (R2) value of 0.9999. Limit of detection (LOD) and limit of quantification (LOQ) of Pb, Cd, and As were 0.001, 0.001, and 0.001 ㎍/L and 0.002, 0.003, and 0.003 ㎍/L, respectively. Accuracy and precision results complied with the criteria presented in the European Commission Joint Research Centre guidelines. The average concentration of Pb, Cd, and As migration detected in a total of 104 samples was 0.009-0.260 ㎍/L, which was very low compared with the migration specification set in the Standards and Specifications for Utensils, Containers, and Packages. The maximum level of Pb corresponded to 0.23% of the migration limit. There were no samples exceeding the limit. Thus, this study confirmed that the heavy metal contents of FCMs used for delivery food distributed in Korea were safely managed. The data from this study represent an invaluable source for science-based safety management of hazardous heavy metals migrating from FCMs used in the food delivery industry.

The progress in NF3 destruction efficiencies of electrically heated scrubbers (전기가열방식 스크러버의 NF3 제거 효율)

  • Moon, Dong Min;Lee, Jin Bok;Lee, Jee-Yon;Kim, Dong Hyun;Lee, Suk Hyun;Lee, Myung Gyu;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.535-543
    • /
    • 2006
  • Being used widely in semiconductor and display manufacturing, $NF_3$ is internationally considered as one of the regulated compounds in emission. Numerous companies have been continuously trying to reduce the emissions of $NF_3$ to comply with the global environmental regulation. This work is made to report the destruction and removal efficiency (DRE) of electrically heated scrubbers and the use rate in process chambers installed in three main LCD manufacturing companies in Korea. As the measurement techniques for $NF_3$ emission, mass flow controlled helium gas was continuously supplied into the equipment by which scrubber efficiency is being measured. The partial pressures of $NF_3$ and helium were accurately measured for each sample using a mass spectrometer, as it is emitted from inlet and outlet of the scrubber system. The results show that the DRE value for electrically heated scrubbers installed before 2004 is less than 52 %, while that for the new scrubbers modified based on measurement by scrubber manufacturer has been sigificentely improved upto more than 95 %. In additon, we have confirmed the efficiency depends on such variables as the inlet gas flow rate, water content, heater temperature, and preventative management period. The use rates of $NF_3$ in process chambers were also affected by the process type. The use rate of radio frequency source chambers, built in the $1^{st}$ and $2^{nd}$ generation process lines, was determined to be less than 75 %. In addition, that of remote plasma source chambers for the $3^{rd}$ generation was measured to be aboove 95 %. Therefore, the combined application of improved scrubber and the RPSC process chamber to the semiconductor and display process can reduce $NF_3$ emmision by 99.95 %. It is optimistic that the mission for the reduction of greenhouse gas emission can be realized in these LCD manufacturing companies in Korea.

Contents of mercury, lead, cadmium, and arsenic in dried marine products (건포류의 수은, 납, 카드뮴 및 비소 함유량)

  • Ok, Hwang Young;Kim, Su Un;Ryu, Seung Hee;Ham, Hee Jin;Park, Gun Yong;Park, Seog Gee
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.336-344
    • /
    • 2009
  • This survey was carried out to estimate the contents of heavy metals (Hg, Pb, Cd, and As) in 10 kinds of dried marine products (n=189) which are closely related to food resources. The contents of heavy metals were estimated by inductively coupled plasma spectrometer (ICP) and mercury analyzer. The values of heavy metals in dried marine products were as follows (Mean${\pm}$SD (range), mg/kg). The average contents of heavy metals in the dried marine products were Hg $0.058{\pm}0.069$ (0.002~0.502) mg/kg, Pb $0.178{\pm}0.598$ (ND~5.130) mg/kg, Cd $0.306{\pm}0.610$ (ND~6.802) mg/kg, As $5.282{\pm}6.158$ (ND~71.760) mg/kg. The range of heavy metal contents in dried marine products are low level, except of lead contents (n=2). In the comparison of heavy metal content by anchovy size, it was shown that cadmium, mercury and arsenic were meaningfully different. The contents of heavy metals by the shape of shrimp and Alaska Pollack were shown that the result of each group was meaningless. In the comparison imported production with domestic production, in the case of common squid, cadmium and arsenic were meaningfully different. The weekly average intakes of Hg, Pb and Cd from dried marine products takes about 1.17~11.52% of PTWI (Provisional Tolerable Weekly Intakes) that FAO/WHO Joint Food Additive and Contaminants Committee has set to evaluate their safeties.

Background effect on the measurement of trace amount of uranium by thermal ionization mass spectrometry (열이온화 질량분석에 의한 극미량 우라늄 정량에 미치는 바탕값 영향)

  • Jeon, Young-Shin;Park, Yong-Joon;Joe, Kih-Soo;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • An experiment was performed for zone refined Re-filament and normal (nonzone refined) Re-filament to reduce the background effect on the measurement of low level uranium samples. From both filaments, the signals which seemed to come from a cluster of light alkali elements, $(^{39}K_6)^+$, $(^{39}K_5+^{41}K)^+$ and $PbO_2$ were identified as the isobaric effect of the uranium isotopes. The isobaric effect signal was completely disappeared by heating the filament about $2000^{\circ}C$ at < $10^{-7}$ torr of vacuum for more than 1.5 hour in zone refined Refilaments, while that from the normal Re-filaments was not disappeared completely and was still remained as 3 pg. of uranium as the impurities after the degassing treatment was performed for more than 5 hours at the same condition of zone refined filaments. A threshold condition eliminating impurities were proved to be at 5 A and 30 minutes of degassing time. The uranium content as an impurity in rhenium filament was checked with a filament degassing treatment using the U-233 spike by isotope dilution mass spectrometry. A 0.31 ng of U was detected in rhenium filament without degassing, while only 3 pg of U was detected with baking treatment at a current of 5.5 A for 1 hr. Using normal Re-filaments for the ultra trace of uranium sample analysis had something problem because uranium remains to be 3 pg on the filament even though degassed for long hours. If the 1 ng uranium were measured, 0.3% error occurred basically. It was also conformed that ionization filament current was recommended not to be increased over 5.5 A to reduce the background. Finally, the contents of uranium isotopes in uranium standard materials (KRISS standard material and NIST standard materials, U-005 and U-030) were measured and compared with certified values. The differences between them showed 0.04% for U-235, 2% for U-234 and 2% for U-236, respectively.

Suggestions of Stone Materials for Restoration of Gwanghwamun Woldae in Seoul Based on Lithological Study (암석학적 연구를 통한 서울 광화문 월대 복원용 석재 제안)

  • Myeong Seong Lee;Yu Bin Ahn;Se Rin Park;Myoungju Choie;Jiyoung Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.647-659
    • /
    • 2023
  • This study is to analyze the lithological similarities between railing stones of Gwanghwamun Woldae and stone blocks stored in Donggureung Royal Tombs, Guri, to interpret the provenance of the stones, and to suggest the most suitable quarry for a new stones supply among the rocks in the Seoul-Pocheon area in order to select stones for the restoration of the Gwanghwamun Woldae. The railing stones in Donggureung are medium to coarse-grained pink biotite granite, and their lithological characteristics, magnetic susceptibility(Average 5.20 ×10-3 SI unit), and gamma spectrometer data(K 5.00~6.38%, U 4.92~8.56 ppm, Th 27.60~36.44 ppm) show similarities with the remaining railing stones in Gwanghwamun Woldae(Average 5.38). Therefore, the railing stones in Donggureung can be reused for the restoration of Gwanghwamun Woldae. They have similar lithological and geochemical charateristics to the pink biotite granite found the Suraksan Mt. and Buramsan Mr. areas in Seoul, suggesting that these areas are the source of the stone. However, since the Suraksan Mt. and Buramsan Mt. areas are currently unavailable for quarrying, lithological and geochemical analyses on granite from the Yangju and Pocheon areas are conducted to determine the suitability of the new stone for restoration. As a result, a pink biotite granite similar to the Woldae stones was identified in the Pocheon area, and it is suggested that the stones similar in grain size and colour to the railing stones of Gwanghwamun Woldae should be selected and used for the restoration of Gwanghwamun Woldae.

Manufacturing Techniques of Bronze Seated Bodhisattva Statue of Goseongsa Temple in Gangjin (강진 고성사 청동보살좌상의 제작기술 연구)

  • LEE Seungchan;BAE Gowoon;CHUNG Kwangyong
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.146-159
    • /
    • 2024
  • In this study, a study on the production technology of the Buddha statue and the production of raw material origin was conducted through scientific analysis on the Bronze seated Bodhisattva Statue of Goseongsa Temple, a treasure. As a result of microstructure analysis through a metal microscope, it was confirmed that the microstructure of the Bronze seated Bodhisattva Statue of Goseongsa Temple was a process-type dendritic structure, and the casting structure of bronze was well represented, so it was manufactured through casting. Subsequently, as a result of analyzing the alloy composition ratio through SEM-EDS, it was identified as a ternary alloy with 81.26 wt% of copper (Cu) and 16.42 wt% of tin (Sn) and 1.72 wt% of lead (Pb). The results of the analysis of lead isotope ratios using a thermal ionization mass spectrometer (TIMS) were substituted into the distribution of lead isotope ratios on the Korean Peninsula, it was shown in corresponding to Jeolla-do and Chungcheong-do regions and North and South Gyeongsang Province. This suggests that the raw materials used in their production were likely sourced from the mines around Goseong Temple in Gangjin. Despite the fact that the statue is a medium and large Buddha with a total height of 51 centimeters, 1.72 wt% of lead (Pb) was found as a result of alloy composition ratio analysis, which showed a similar composition to the lead content ratio of small bronze and gilt-bronze Buddha statues. Therefore, we compared and analyzed the results of the analysis of the composition ratio of the alloys of bronze and gilt bronze statues, which has been scientifically analyzed with a compositional age similar to that of the Bronze seated Bodhisattva Statue of Goseongsa Temple. Comparison results, Various factors, such as the size of the Buddha statue as well as its stylistic characteristics and the age of composition, may exist in determining the alloy composition ratio of the bronze and gilt bronze Buddha statues, and it was confirmed that the alloy composition ratio or casting technology was properly adjusted when the Buddha statue was created. In other words, it is judged that a more comprehensive system of Buddha statue production technology should be investigated by conducting archaeological and art history studies on stylistic characteristics and age of composition, as well as scientific analysis results such as observation of internal structure, microstructure observation, and analysis of alloy composition ratio using radiation transmission irradiation.

The Chemical Composition and Working Techniques of the Glass Beads Excavated in the Jisan-dong No. 73-74 Ancient Tombs, Goryeong (고령 지산동 73~74호분 출토 유리구슬의 제작 기법과 화학 조성)

  • Kim Nayoung;Kim Euna;Kim Gyuho
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.21-37
    • /
    • 2024
  • This paper sought to garner an understanding of Daegaya glass culture by observing the micro-structure and analyzing the chemical composition of 43 glass beads excavated from the No.73 and 74 ancient tombs in Jisan-dong, Goryeong, which are estimated to have a central age of 5th century CE. The visible characteristics and micro-structure of these artifacts were observed with a optical microscope and an scanning electron microscope, while their chemical composition was analyzed with an energy-dispersing spectrometer attached to the scanning electron microscope. As a result, the glass beads of Jisan-dong, Goryeong were identified to have been formed using various methods such as drawing, casting, and folding techniques, with the majority molded by the drawing technique. In terms of chemical composition, 32.6% were in the potash glass group and 67.4% in the soda glass group, with the latter divided into various fluxes such as high alumina glass, netron glass, and plant ash glass. Compared to Baekje's cultural region in the same age, the composition of these ancient glass artifacts demonstrates a high share of the potash glass group. This shows that, despite the shift from the potash glass group to the soda glass group in ancient Korean glass culture, glass composition differs from region to region or depending on the cultural sphere of influence. In the soda glass group, high-alumina glass comprised 23.3%, natron glass 43.0%, and plant ash glass was 1.2%. Among them, the main type of Korean soda glass is high-alumina glass, as natron glass and plant ash glass are known to have appeared later, but the results of scientific analysis of the glass beads excavated in Jisan-dong can be expected to provide important clues about the inflow and transformation of ancient glass on the Korean Peninsula. In the No. 73, 74, and 74-1 ancient tombs, which were found to have been built in chronological order by the excavation survey, the glass beads showed only slight variations depending on their production period. Nonetheless, the chemical composition of glass is deemed to have a close correlation to color.

Radiosynthesis of $[^{11}C]6-OH-BTA-1$ in Different Media and Confirmation of Reaction By-products. ($[^{11}C]6-OH-BTA-1$ 조제 시 생성되는 부산물 규명과 반응용매에 따른 표지 효율 비교)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Lee, Eun-Kyoung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.241-246
    • /
    • 2007
  • Purpose: $[^{11}C]6-OH-BTA-1$ ([N-methyl-$^{11}C$]2-(4'-methylaminophenyl)-6-hydroxybenzothiazole, 1), a -amyloid imaging agent for the diagnosis of Alzheimer's disease in PET, can be labeled with higher yield by a simple loop method. During the synthesis of $[^{11}C]1$, we found the formation of by-products in various solvents, e.g., methylethylketone (MEK), cyclohexanone (CHO), diethylketone (DEK), and dimethylformamide (DMF). Materials and Methods: In Automated radiosynthesis module, 1 mg of 4-aminophenyl-6-hydroxybenzothiazole (4) in 100 l of each solvent was reacted with $[^{11}C]methyl$ triflate in HPLC loop at room temperature (RT). The reaction mixture was separated by semi-preparative HPLC. Aliquots eluted at 14.4, 16.3 and 17.6 min were collected and analyzed by analytical HPLC and LC/MS spectrometer. Results: The labeling efficiencies of $[^{11}C]1$ were $86.0{\pm}5.5%$, $59.7{\pm}2.4%$, $29.9{\pm}1.8%$, and $7.6{\pm}0.5%$ in MEK, CHO, DEK and DMF, respectively. The LC/MS spectra of three products eluted at 14.4, 16.3 and 17.6 mins showed m/z peaks at 257.3 (M+1), 257.3 (M+1) and 271.3 (M+1), respectively, indicating their structures as 1, 2-(4'-aminophenyl)-6-methoxybenzothiazole (2) and by-product (3), respectively. Ratios of labeling efficiencies for the three products $([^{11}C]1:[^{11}C]2:[^{11}C]3)$ were $86.0{\pm}5.5%:5.0{\pm}3.4%:1.5{\pm}1.3%$ in MEK, $59.7{\pm}2.4%:4.7{\pm}3.2%:1.3{\pm}0.5%$ in CHO, $9.9{\pm}1.8%:2.0{\pm}0.7%:0.3{\pm}0.1%$ in DEK and $7.6{\pm}0.5%:0.0%:0.0%$ in DMF, respectively. Conclusion: The labeling efficiency of $[^{11}C]1$ was the highest when MEK was used as a reaction solvent. As results of mass spectrometry, 1 and 2 were conformed. 3 was presumed.

IR Study on the Adsorption of Carbon Monoxide on Silica Supported Ruthenium-Nickel Alloy (실리카 지지 루테늄-니켈 합금에 있어서 일산화탄소의 흡착에 관한 IR 연구)

  • Park, Sang-Youn;Yoon, Dong-Wook
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.349-356
    • /
    • 2006
  • We have investigated adsorption and desorption properties of CO adsorption on silica supported Ru/Ni alloys at various Ru/Ni mole content ratio as well as CO partial pressures using Fourier transform infrared spectrometer (FT-IR). For Ru-$SiO_{2}$ sample, four bands were observed at $2080.0cm^{-1}$, $2021.0{\sim}2030.7cm^{-1}$, $1778.9{\sim}1799.3cm^{-1}$, $1623.8cm^{-1}$ on adsorption and three bands were observed at $2138.7cm^{-1}$, $2069.3cm^{-1}$, $1988.3{\sim}2030.7cm^{-1}$ on vacumn desorption. For Ni-$SiO_{2}$ sample, four bands were observed at $2057.7cm^{-1}$, $2019.1{\sim}2040.3cm^{-1}$, $1862.9{\sim}1868.7cm^{-1}$, $1625.7cm^{-1}$ on adsorption and two bands were observed at $2009.5{\sim}2040.3cm^{-1}$, $1828.4{\sim}1868.7cm^{-1}$ on vacumn desorption. These absorption bands correspond with those of the previous reports approximately. For Ru/Ni(9/1, 8/2, 7/3, 6/4, 5/5; mole content ratio)-$SiO_{2}$ samples, three bands were observed at $2001.8{\sim}2057.7cm^{-1}$, $1812.8{\sim}1926.5cm^{-1}$, $1623.8{\sim}1625.7cm^{-1}$ on adsorption and three bands were observed at $2140.6cm^{-1}$, $2073.1cm^{-1}$, $1969.0{\sim}2057.7cm^{-1}$ on vacumn desorption. The spectrum pattern observed for Ru/Ni-$SiO_{2}$ sample at 9/1 Ru/Ni mole content ratio on CO adsorption and on vacumn desorption is almost like the spectrum pattern observed for Ru-$SiO_{2}$ sample. But the spectrum patterns observed for Ru/Ni-$SiO_{2}$ samples under 8/2 Ru/Ni mole content ratio on CO adsorption and vacumn desorption are almost like the pattern observed for $Ni-SiO_{2}$ sample. It may be suggested surfaces of alloy clusters on the Ru/Ni-$SiO_{2}$ samples contain more Ni components than the mole content ratio of the sample considering the above phenomena. With Ru/Ni-$SiO_{2}$ samples the absorption band shifts may be ascribed to variations of surface concentration, strain variation due to atomic size difference, variation of bonding energy and electronic densities, and changes of surface geometries according to surface concentration variation. Studies for CO adsorption on Ru/Ni alloy cluster surface by LEED and Auger spectroscopy, interation between Ru/Ni alloy cluster and $SiO_{2}$, and MO calculation for the system would be needed to look into the phenomena.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF