• 제목/요약/키워드: spectral shape factor

검색결과 12건 처리시간 0.016초

Analog active valve control design for non-linear semi-active resetable devices

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Corman, Sylvain
    • Smart Structures and Systems
    • /
    • 제19권5호
    • /
    • pp.487-497
    • /
    • 2017
  • Semi-active devices use the building's own motion to produce resistive forces and are thus strictly dissipative and require little power. Devices that independently control the binary open/closed valve state can enable novel device hysteresis loops that were not previously possible. However, some device hysteresis loops cannot be obtained without active analog valve control allowing slower, controlled release of stored energy, and is presents an ongoing limitation in obtaining the full range of possibilities offered by these devices. This in silico study develops a proportional-derivative feedback control law using a validated nonlinear device model to track an ideal diamond-shaped force-displacement response profile using active analog valve control. It is validated by comparison to the ideal shape for both sinusoidal and random seismic input motions. Structural application specific spectral analysis compares the performance for the non-linear, actively controlled case to those obtained with an ideal, linear model to validate that the potential performance will be retained when considering realistic nonlinear behaviour and the designed valve control approach. Results show tracking of the device force-displacement loop to within 3-5% of the desired ideal curve. Valve delay, rather than control law design, is the primary limiting factor, and analysis indicates a ratio of valve delay to structural period must be 1/10 or smaller to ensure adequate tracking, relating valve performance to structural period and overall device performance under control. Overall, the results show that active analog feedback control of energy release in these devices can significantly increase the range of resetable, valve-controlled semi-active device performance and hysteresis loops, in turn increasing their performance envelop and application space.

유량에 따른 대기압 유전체 전위장벽방전(DBD) 플라즈마 젯 발생에 관한 연구 (A Study of Atmospheric-pressure Dielectric Barrier Discharge (DBD) Volume Plasma Jet Generation According to the Flow Rate)

  • 정병호
    • 산업융합연구
    • /
    • 제21권7호
    • /
    • pp.83-92
    • /
    • 2023
  • 유전체 전위장벽방전방식에 의한 플라즈마 젯의 블렛 형상은 인가되는 유량과 전기장의 크기에 따라 달라지고 이러한 변화는 DBD 플라즈마 젯의 밀도차이에 의한 스펙트럼 분포의 차이로 나타난다. 발생된 플라즈마 젯의 스펙트럼의 분석을 통한 활성종의 발생과 강도의 차이는 장치를 활용하는데 있어서 중요한 요소이다. 본 논문에서는 Ar가스를 이용한 대기압 볼륨 DBD방식의 플라즈마 젯 발생장치를 제안된 설계방법에 따라 구성하였다. 플라즈마 젯의 발생을 위한 유량의 의존도를 규명하기 위한 Ar가스의 유동해석을 시뮬레이션을 통해 확인하였고 프로토타입 시스템에서는 MFC를 통한 유량제어를 통해 최적의 플라즈마 젯 불렛형상을 발생시키고 발생된 플라즈마 젯의 특성을 분석하기 위해 스펙트로미터를 이용한 플라즈마 젯의 특성을 분석하였다. 제안된 시스템의 설계방법을 통한 장치에서 최적의 플라즈마 젯 형상 확립방법과 EOS 상에서 활성종에 대한 결과를 확인하였다.