• Title/Summary/Keyword: spectral peak

Search Result 505, Processing Time 0.028 seconds

Growth of ZnTe Thin Films by Oxygen-plasma Assisted Pulsed Laser Deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.185-185
    • /
    • 2011
  • ZnTe semiconductor is very attractive materials for optoelectronic devices in the visible green spectral region because of it has direct bandgap of 2.26 eV. The prototypes of ZnTe light emitting diodes (LEDs) have been reported [1], showing that their green emission peak closely matches the most sensitive region of the human eye. Another application to photovoltaics proved that ZnTe is useful for the production of high-efficiency multi-junction solar cells [2,3]. By using the pulse laser deposition system, ZnTe thin films were deposited on ZnO thin layer, which is grown on (0001) Al2O3substrates. To produce the plasma plume from an ablated ZnO and ZnTe target, a pulsed (10 Hz) YGA:Nd laser with energy density of 95 mJ/$cm^2$ and wavelength of 266 nm by a nonlinear fourth harmonic generator was used. The laser spot focused on the surface of the ZnO and ZnTe target by using an optical lens was approximately 1 mm2. The base pressure of the chamber was kept at a pressure around $10^{-6}$ Torr by using a turbo molecular pump. The oxygen gas flow was controlled around 3 sccm by using a mass flow controller system. During the ZnTe deposition, the substrate temperature was $400^{\circ}C$ and the ambient gas pressure was $10^{-2}$ Torr. The structural properties of the samples were analyzed by XRD measurement. The optical properties were investigated by using the photoluminescence spectra obtained with a 325 nm wavelength He-Cd laser. The film surface and carrier concentration were analyzed by an atomic force microscope and Hall measurement system.

  • PDF

Spectral Analysis for Non-Invasive Total Hemoglobin Measurement in the Region from 400 to 2500nm (총헤모글로빈 농도를 비침습적으로 측정하기 위한 400-2500nm 대역의 흡수 스펙트럼 분석)

  • Jeon, Kye-Jin;Kim, Yoen-Joo;Kim, Su-Jin;Kim, Hong-Sig;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.273-278
    • /
    • 2001
  • Absorption spectra of blood components have been measured for the purpose of predicting the total hemoglobin concentration. We obtained absorption spectra of major blood components from the visible to near-infrared of $400{\sim}2500nm$ region. In the near-infrared, water is the main absorbing constituent. The amount of water in the sample cell varies depending on the volume of solute concentration(water displacement). We acquired water-compensated spectra by considering the variation of water volume depending on the variation of analyze concentration. Those spectra show inherent absorption peaks of analyzes and linearity with respect to concentration. We selected wavelengths for non-invasive measurement of hemoglobin concentration considering the scattering effect of tissue and the interference of other blood components.

  • PDF

Fabrication and $^{60}Co$ Gamma Induced Damage of Plastic Scintillators (플라스틱 섬광체의 제작과 $^{60}Co$ $\gamma$-선에 의한 방사선 손상)

  • Kim, Sung-Hwan;Nam, Seung-Hee;Cheon, Jong-Kyu;Kim, Wan;Kang, Hee-Dong;Kim, Do-Sung;Lee, Woo-Gyo;Doh, Sih-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.350-356
    • /
    • 2000
  • The optimum composition ratios of primary solute(p-terphenyl) and secondary solute(popop) have been investigated in order to fabricate plastic scintillator with higher light output and less radiation damage. The radiation damage induced by $^{60}Co$ $\gamma$-irradiation depends on mainly the concentration of secondary solute. The spectral range of the luminescence was $400{\sim}450\;nm$, its peak emission appeared at 415 nm. The transmittance and the light output were not changed by radiation damage up to $1{\times}10^4\;Gy$ irradiation with $^{60}Co$ $\gamma$-rays.

  • PDF

40.8 MHz coherent scatter ionospheric radar observations of E- and F-region field aligned irregularities over Korea

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jae-Jin;Choi, Seong-Hwan;Hwang, Jung-A;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2011
  • The new coherent scatter ionospheric radar has been operating at Gyerong city ($36.18^{\circ}N$, $127.14^{\circ}E$, dip lat $26.7^{\circ}N$), South Korea. This VHF radar is consisted of 24 Yagi antennas having 5 elements and observes the E- and F-region field-aligned irregularities (FAIs) in a single frequency of 40.8 MHz with a peak power of 24 kW. We present the first results of the E- and F-region FAIs over Korea by using the new VHF coherent scatter ionospheric radar. The morphological and echo characteristics are studied in terms of their echo strength, Doppler velocity and also by spectral width values. From the continuous observations from December 2009, we found ionospheric E- and F-region FAIs appeared frequently. The most interesting and striking observations for E region are occurrence of daytime E-region irregularities and strong Quasi-Periodic (QP) echoes at nighttime. And for F region, strong post-sunset and pre-sunrise FAIs appeared frequently. The VHF radar observations over Korea are discussed in the light of current understanding of mid-latitude E- and F-region FAIs.

  • PDF

Green Phosphorescent OLED Without a Hole/Exciton Blocking Layer Using Intermixed Double Host and Selective Doping

  • Kim, Won-Ki;Kim, Hyung-Seok;Shin, Hyun-Kwan;Jang, Ji-Geun
    • Korean Journal of Materials Research
    • /
    • v.19 no.5
    • /
    • pp.240-244
    • /
    • 2009
  • Simple and high efficiency green phosphorescent devices using an intermixed double host of 4, 4', 4"-tris(N-carbazolyl) triphenylamine [TCTA], 1, 3, 5-tris (N-phenylbenzimiazole-2-yl) benzene [TPBI], phosphorescent dye of tris(2-phenylpyridine)iridium(III) [$Ir(ppy)_3$], and selective doping in the TPBI region were fabricated, and their electro luminescent characteristics were evaluated. In the device fabrication, layers of $70{\AA}$-TCTA/$90{\AA}$-$TCTA_[0.5}TPBI_{0.5}$/$90{\AA}$-TPBI doped with $Ir(ppy)_3$ of 8% and an undoped layer of $50{\AA}$-TPBI were successively deposited to form an emission region, and SFC137 [proprietary electron transporting material] with three different thicknesses of $300{\AA}$, $500{\AA}$, and $700{\AA}$ were used as an electron transport layer. The device with $500{\AA}$-SFC137 showed the luminance of $48,300\;cd/m^2$ at an applied voltage of 10 V, and a maximum current efficiency of 57 cd/A under a luminance of $230\;cd/m^2$. The peak wavelength in the electroluminescent spectral and color coordinates on the Commission Internationale de I'Eclairage [CIE] chart were 512 nm and (0.31, 0.62), respectively.

Dielectric Thin Film Mirror Embedded Optical Fiber Couplers (유전체 박막 거울 내장형 광섬유 결합기)

  • 신종덕
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.420-427
    • /
    • 1993
  • Dielectric thin film mirrors are embedded in multimode and single-mode fibers by a fusion splicing technique. The fibers with $45{\circ}$ angled embedded mirrors serve as ultra-compact directional couplers with low excess optical loss of 0.2 dB for multimode and 0.5 dB for single mode at 1.3 ${\mu}m$ and excellent mechanical properties. The reflectance is wavelength dependent and strongly polarization depencient. Far-field scans of the reflected output power measured with a white-light source show a pattern which is almost circularly symmetric with aspect ratio of 1.09 at 5% of the peak power. The splitting ratio in a multimode coupler measured with a diode laser source is much less dependent on input coupling conditions than in conventional fused biconical-taper couplers, indicating that these couplers are less susceptible to modal noise occuring in optical fiber communication systems. Spectral properties of multilayer internal mirrors normal to the fiber axis have been investigated experimentally, and a matrix analysis has been used to explain the results.

  • PDF

Investigation of Degradation Mechanism of Rabeprazole with Solid State Pharmaceutical Excipients

  • Ren, Shan;Tran, Thao Truong-Dinh;Tran, Phuong Ha-Lien;Rhee, Yun-Seok;Lee, Beom-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.6
    • /
    • pp.367-372
    • /
    • 2010
  • Rabeprazole sodium (RPN) is known to be very unstable at acidic condition or some acidic pharmaceutical excipients such as acrylic acid polymer (carbomer 934) with carboxylic acids. Thus, degradation mechanism of binary blends of rabeprazole with pharmaceutical excipients in a solid state without using solvents at three different ratios (3:1, 1:1 and 1:3) was investigated using Fourier transform infrad (FTIR) spectroscopy. Alkalizer (MgO), neutral hydroxypropymethylcellulose (HPMC 4000) were also tested for comparison. The binary blends were stored under accelerated conditions ($40^{\circ}C$/75% relative humidity) for two weeks. The concentration of thioether rabeprazole from the binary blends with acidic carbomer 934 increased as the rabeprazole concentration decreased. In addition, the degradation half-life of rabeprazole as well as the relative peak area ratios obtained from FTIR spectra of S=O stretching at $1094.1\;cm^{-1}$ decreased consistently as the fraction of carbomer 934 increased due to its sensitivity between the basic benzimidazole nitrogen and carboxylic acid group of carbomer 934. The physical appearance also turned into strong brown color in the presence of carbomer 934. In contrast, there were no significant changes in the degradation kinetics of rabeprazole with MgO and HPMC 4000 in a solid state. This present study demonstrated that the solid-state compatibility test with the aid of HPLC chromatographic and FTIR spectral analyses could offer a valuable methodology to select suitable pharmaceutical excipients and to elucidate the degradation mechanism of RPN for drug formulations at the early formulation stages.

Electrophysiological and Histologic Evaluation of the Time Course of Retinal Degeneration in the rd10 Mouse Model of Retinitis Pigmentosa

  • Jae, Seol A;Ahn, Kun No;Kim, Ji Young;Seo, Je Hoon;Kim, Hyong Kyu;Goo, Yong Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.3
    • /
    • pp.229-235
    • /
    • 2013
  • Among several animal models of retinitis pigmentosa (RP), the more recently developed rd10 mouse with later onset and slower rate of retinal degeneration than rd1 mouse is a more suitable model for testing therapeutic modalities. We therefore investigated the time course of retinal degeneration in rd10 mice before adopting this model in our interventional studies. Electroretinogram (ERG) recordings were carried out in postnatal weeks (PW) 3~5 rd10 (n=23) and wild-type (wt) mice (n=26). We compared the amplitude and implicit time of the b-wave of ERG records from wt and rd10 mice. Our results showed that b-wave amplitudes in rd10 mice were significantly lower and the implicit time of b-waves in rd10 mice were also significantly slower than that in wt mice ($20{\sim}160{\mu}V$ vs. $350{\sim}480{\mu}V$; 55~75 ms vs. 100~150 ms: p<0.001) through PW3 to PW5. The most drastic changes in ERG amplitudes and latencies were observed during PW3 to PW4. In multichannel recording of rd10 retina in PW2 to PW4.5, we found no significant difference in mean spike frequency, but the frequency of power spectral peak of local field potential at PW3 and PW3.5 is significantly different among other age groups (p<0.05). Histologic examination of rd10 retinae showed significant decrease in thickness of the outer nuclear layer at PW3. TUNEL positive cells were most frequently observed at PW3. From these data, we confirm that in the rd10 mouse, the most precipitous retinal degeneration occurs between PW3~PW4 and that photoreceptor degeneration is complete by PW5.

Foundation-soil-foundation Interaction of Shallow Foundations Using Geo Centrifuge: Experimental Approach (원심모형실험을 이용한 얕은 기초의 기초-지반-기초 상호작용: 실험적 접근)

  • Ngo, Linh Van;Kim, Jae-Min;Lim, Jaesung;Lee, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • Geocentrifuge tests are performed to investigate the structure-soil-structure interaction of shallow foundations that have various sizes. The soil specimen is prepared by using the air-pluviation, and the dynamic responses of the foundation are monitored with separation distances between the two foundations and the embedment. During the centrifugal test, the measured ground acceleration shows a tendency to increase with the increase of the input seismic amplitude, and maximum acceleration is measured at the surface due to the ground amplification. As the separation distance between the two foundations decreases, the ratio of the response spectral acceleration (RRS) increases and the period at the peak RRS decreases due to the structure-soil-structure interaction (SSSI). The RRS of the two foundations tends to decrease when the foundations are buried in the ground at the same separation distance.

Multispectral Image Data Compression Using Classified Prediction and KLT in Wavelet Transform Domain (웨이블릿 영역에서 분류 예측과 KLT를 이용한 다분광 화상 데이터 압축)

  • 김태수;김승진;이석환;권기구;김영춘;이건일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.533-540
    • /
    • 2004
  • This paper proposes a new multispectral image data compression algorithm that can efficiently reduce spatial and spectral redundancies by applying classified prediction, a Karhunen-Loeve transform (KLT), and the three-dimensional set partitioning in hierarchical trees (3-D SPIHT) algorithm in the wavelet transform (WT) domain. The classification is performed in the WT domain to exploit the interband classified dependency, while the resulting class information is used for the interband prediction. The residual image data on the prediction errors between the original image data and the predicted image data is decorrelated by a KLT. Finally, the 3-D SPIHT algorithm is used to encode the transformed coefficients listed in a descending order spatially and spectrally as a result of the WT and KLT. Simulation results showed that the reconstructed images after using the proposed algorithm exhibited a better quality and higher compression ratio than those using conventional algorithms.