• Title/Summary/Keyword: spectral peak

Search Result 509, Processing Time 0.03 seconds

Connection of spectral pattern of carbohydrate molecular structure to alteration of nutritional properties of coffee by-products after fermentation

  • Samadi;Xin Feng;Luciana Prates;Siti Wajizah;Zulfahrizal;Agus Arip Munawar;Weixian Zhang;Peiqiang Yu
    • Animal Bioscience
    • /
    • v.37 no.8
    • /
    • pp.1398-1407
    • /
    • 2024
  • Objective: The objective of this study was to determine internal structure spectral profile of by-products from coffee processing that were affected by added-microorganism fermentation duration in relation to truly absorbed feed nutrient supply in ruminant system. Methods: The by-products from coffee processing were fermented using commercial fermentation product, consisting of various microorganisms: for 0 (control), 7, 14, 21, and 28 days. In this study, carbohydrate-related spectral profiles of coffee by-products were correlated with their chemical and nutritional properties (chemical composition, total digestible nutrient, bioenergy values, carbohydrate sub-fractions and predicted degradation and digestion parameters as well as milk value of feed). The vibrational spectra of coffee by-products samples after fermentation for 0 (control), 7, 14, 21, and 28 days were determined using a JASCO FT/IR-4200 spectroscopy coupled with accessory of attenuated total reflectance (ATR). The molecular spectral analyses with univariate approach were conducted with the OMNIC 7.3 software. Results: Molecular spectral analysis parameters in fermented and non-fermented by-products from coffee processing included structural carbohydrate, cellulosic compounds, non-structural carbohydrates, lignin compound, CH-bending, structural carbohydrate peak1, structural carbohydrate peak2, structural carbohydrate peak3, hemicellulosic compound, non-structural carbohydrate peak1, non-structural carbohydrate peak2, non-structural carbohydrate peak3. The study results show that added-microorganism fermentation induced chemical and nutritional changes of coffee by-products including carbohydrate chemical composition profiles, bioenergy value, feed milk value, carbohydrate subfractions, estimated degradable and undegradable fractions in the rumen, and intestinal digested nutrient supply in ruminant system. Conclusion: In conclusion, carbohydrate nutrition value changes by added-microorganism fermentation duration were in an agreement with the change of their spectral profile in the coffee by-products. The studies show that the vibrational ATR-FT/IR spectroscopic technique could be applied as a rapid analytical tool to evaluate fermented by-products and connect with truly digestible carbohydrate supply in ruminant system.

Identification Performance of Low-Molecular Compounds by Searching Tandem Mass Spectral Libraries with Simple Peak Matching

  • Milman, Boris L.;Zhurkovich, Inna K.
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.73-76
    • /
    • 2018
  • The number of matched peaks (NMP) is estimated as the spectral similarity measure in tandem mass spectral library searches of small molecules. In the high resolution mode, NMP provides the same reliable identification as in the case of a common dot-product function. Corresponding true positive rates are ($94{\pm}3$) % and ($96{\pm}3$) %, respectively.

Optimal earthquake intensity measures for probabilistic seismic demand models of ARP1400 reactor containment building

  • Nguyen, Duy-Duan;Thusa, Bidhek;Azad, Md Samdani;Tran, Viet-Linh;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4179-4188
    • /
    • 2021
  • This study identifies efficient earthquake intensity measures (IMs) for seismic performances and fragility evaluations of the reactor containment building (RCB) in the advanced power reactor 1400 (APR1400) nuclear power plant (NPP). The computational model of RCB is constructed using the beam-truss model (BTM) for nonlinear analyses. A total of 90 ground motion records and 20 different IMs are employed for numerical analyses. A series of nonlinear time-history analyses are performed to monitor maximum floor displacements and accelerations of RCB. Then, probabilistic seismic demand models of RCB are developed for each IM. Statistical parameters including coefficient of determination (R2), dispersion (i.e. standard deviation), practicality, and proficiency are calculated to recognize strongly correlated IMs with the seismic performance of the NPP structure. The numerical results show that the optimal IMs are spectral acceleration, spectral velocity, spectral displacement at the fundamental period, acceleration spectrum intensity, effective peak acceleration, peak ground acceleration, A95, and sustained maximum acceleration. Moreover, weakly related IMs to the seismic performance of RCB are peak ground displacement, root-mean-square of displacement, specific energy density, root-mean-square of velocity, peak ground velocity, Housner intensity, velocity spectrum intensity, and sustained maximum velocity. Finally, a set of fragility curves of RCB are developed for optimal IMs.

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

Evaluation of Concentration using Electroencephalogram during Arithmetic Task (뇌파를 이용한 암산작업시의 집중도 평가)

  • 윤용현;고한우;김동윤;한화영
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.53-56
    • /
    • 2000
  • 인간의 집중도 변화를 평가하기 위하여 피험자에게 암산과제를 부가하고 뇌파신호를 전두엽(Fpl, Fp2)으로부터 측정하였다. alpha band의 최대 peak 주파수 변화를 compressed spectral array를 사용하여 관찰하고 theta(3.5-7 Hz), alpha(7.5-13.0 Hz), beta(13.5-20 Hz) band 전력을 정규화하여 분포를 구했다. 평가결과, 집중도가 높아짐에 따라 alpha band의 최대 peak 주파수는 낮은 주파수 대에서 높은 주파수대로 이동하고, slow alpha band의 전력은 감소, fast alpha band의 전력은 증가하였다. 또한 뇌파신호의 각 band 전력의 분포는 theta band는 증가, alpha band는 감소하였다.

  • PDF

On Long-term Prediction Scheme in Ocean Engineering

  • Kwon, Sun-Hong;Kim, Dea-Woong
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.3 no.1
    • /
    • pp.29-34
    • /
    • 2000
  • This paper proposes a long-term prediction of offshore structures in ocean waves. All short-term statistics is generated by the simulation for all the combinations of significant wave heights and spectral peak periods. The simulation has been tested first on linear system, whose analytic solution is known, to verify if the simulation works accurately. Then the scheme was applied to the nonlinear system. This paper demonstrated that the proposed scheme could be an efficient tool in estimating the response of offshore structures.

  • PDF

Effect of the difference in spectral outputs of the single and dual-peak LEDs on the microhardness and the color stability of resin composites (Single-peak LED와 dual-peak LED의 출력 파장 차이가 복합 레진 미세 경도와 색 안정성에 미치는 영향)

  • Park, Hye-Jung;Son, Sung-Ae;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.108-113
    • /
    • 2011
  • Objectives: To determine the effect of the spectral output of single and dual-peak light emitting diode (LED) curing lights on the microhardness and color stability of commercial resin composites formulated with camphorquinone and alternative photoinitiators in combination. Materials and Methods: Three light-polymerized resin composites (Z100 (3M ESPE), Tetric Ceram (Ivoclar Vivadent) and Aelite LS Posterior (Bisco)) with different photoinitiator systems were used. The resin composites were packed into a Teflon mold (8 mm diameter and 2 mm thickness) on a cover glass. After packing the composites, they were light cured with single-peak and dual-peak LEDs. The Knoop microhardness (KHN) and color difference (${\Delta}E$) for 30 days were measured. The data was analyzed statistically using a student's t-test (p < 0.05). Results: All resin composites showed improved microhardness when a third-generation dual-peak LED light was used. The color stability was also higher for all resin composites with dual-peak LEDs. However, there was a significant difference only for Aelite LS Posterior. Conclusions: The dual-peak LEDs have a beneficial effect on the microhardness and color stability of resin composites formulated with a combination of camphorquinone and alternative photoinitiators.

Comparative Study of the Symbol Rate Detection of Unknown Digital Communication Signals (미상 디지털 통신 신호의 심볼율 검출 방식 비교)

  • Joo, Se-Joon;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents and compares several techniques that detect the symbol rate of unknown received signal. Symbol rate is detected from the power spectral density of the circuits such as the delay and multiplier circuit, the square law circuit, and analytic signal, etc. As a result of discrete Fourier transform of the output signals of these circuits, a lot of spectral lines and some peaks appear in frequency domain and the position of first peak is corresponding to the symbol rate. If a spectral line on the frequency that is not located in symbol rate is larger than the first peak, the symbol rate is erroneously detected. Thus, the ratio between the value of first peak and the highest side spectral line is used for the measure of the performance of symbol rate detector. For the MPSK modulation, the analytic signal method shows better performance than the delay and multiplier and square law circuits when the received signal power is lager than -20dB. It is also noted that the delay and multiplier circuit is not able to detect the symbol rate for the QAM modulation.

  • PDF

Algorithm to Improve Mass Spectral Resolution of Gas Chromatography Mass Spectrometer (가스크로마토그래피 질량분석기의 질량 스펙트럼 해상도 개선 알고리즘)

  • Choi, Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1232-1238
    • /
    • 2018
  • This paper proposes methods for improving mass spectral resolution for a gas chromatograph mass spectrometer. The slope signs of the 1st and 2nd fitting functions for the ion signal block of each mass index are obtained, and the unnecessary element signals in the ion signal block are removed. The spectrum can be obtained by obtaining the second-order fitting function of the reconstructed ion signal block using only the effective ion signals. In addition, the resolution of the mass spectrum can be improved by correcting the error caused by the shift of the spectral peak position. To verify the performance of the proposed methods, computer simulations were performed using the actual ion signals obtained from the GC-MS system under development. Simulation results show that the proposed method is valid.

Study on the Diagnosis of Abnormal Prosthetic Valve

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The two major problems related to the blood flow in replaced prosthetic heart valve are thrombus formation and hemolysis. Reliability of prosthetic valve is very important because its failure means the death of patient. There are many factors affecting the valvular failures and their representatives are mechanical failure and thrombosis, so early noninvasive detection is essentially required. The purpose of this study is to detect the various thromboses formation by using acoustic signal acquisition and its spectral analysis on the frequency domain. We made the thrombosis models using Polydimethylsiloxane (PDMS) and they are thrombosis model on the disc, around the sewing ring and fibrous tissue growth across the orifice of valve. Using microphone and amplifier, we measured the acoustic signal from the prosthetic valve, which is attached to the pulsatile mock circulation system. A/D converter sampled the acoustic signal and the spectral analysis is the main algorithm for obtaining spectrum. Then the spectrum of normal and 5 different kinds of abnormal valve were obtained. Each spectrum waveform shows a primary and secondary peak. The secondary peak changes according to the thrombus model. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. Acoustic measurement has been used as a noninvasive diagnostic tool and is thought to be a good method for detecting possible mechanical failure or thrombus.