• Title/Summary/Keyword: spectral calibration

Search Result 253, Processing Time 0.028 seconds

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

Design and Calibration of Acousto-Optic Tunable Filter(AOTF) for Near Infrared Spectral Analysis (근적외선 분광 분석을 위한 음향광학변조필터의 설계 및 교정)

  • You, Jang-Woo;Kim, Dae-Suk;Kwak, Yoon-Keun;Kim, Soo-Hyun;Lee, Yun-Woo;Hwang, In-Duk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1697-1702
    • /
    • 2004
  • In this paper, we proposed the design and calibration method for the near infrared Acousto-Optic Tunable Filter (AOTF). The theory and design principles of AOTF for the visible light are well known since I.C.Chang has developed the parallel tangent condition for the non-collinear AOTF. Deflection angle, frequency-wavelength relation, spectral resolution, etc. were calculated based on the theory of AOTF. From this result, important parameters - incident and acoustic angle - to fabricate AOTF were decided. We measured the spectral resolution and the relation between electrical driving frequency and the Optical wavelength of diffracted light to calibrate the near infrared AOTF. About 40 ∼ 80 MHz electrical frequency was required to get 1200 ∼ 2200 nm near infrared light. Spectral resolution was less than 10 nm in the near infrared region.

MATURE INSTRUMENT, IMMATURE TECHNOLOGY : IS NIR ANALYSIS OF HIGH MOISTURE MATERIALS A SERIOUS PROPOSITION\ulcorner

  • Berding, Nils
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3124-3124
    • /
    • 2001
  • The development and evolution of near infra-red spectroscopic (NIS) calibrations for high-moisture materials is an expensive proposition. Such investment is suspect unless the instrument, or instruments, on which calibrations were developed can be preserved intact or re-standardized as component replacements occurs. The objective of this paper is to detail the changes in performance of a six-year old instrument after maintenance in years five and six resulted in collection of spectral data that was increasingly removed from the calibration population. Calibrations for the analysis of mature sugarcane stalks, a high-moisture material, were developed successfully in 1995 using a broad sample population in terms of genetics, and spectral and temporal variation. The spectral library was further broadened in 1996. In 1997, 1999, 1999, and 2000, additional samples constituting 10% of the laboratories throughput were subjected to full component analyses using routine laboratory techniques. These samples were primarily random samples, but were complemented with samples that were significant for the spectral H statistic or for the component t statistic. In 1998, an additional calibration was developed for populations consisting of samples of either mature stalks (culms) or sucker culms. Substantial additional samples numbers were collected for this calibration in 1999 and 2000. Attempts to standardize the scanning spectrophotometer used for these calibrations with a second similar instrument in 1999 failed because the instruments were optically different, and standardization could not account for this. Maintenance adjustments were made to the remote reflectance probe of the original instrument in 1999, and replacement of its PbS detectors was done in 2000. Spectral data collected in 1999 and 2000 yielded spectral populations that were increasingly removed from the respective spectral populations on which the calibrations were developed. The mature stalk calibrations benefited marginally from evolutionary calib.

  • PDF

POLARIZATION-MAGNETIC FIELD CALIBRATION CURVE (편광-자기장 눈금조정 곡선)

  • Kim, Kap-Sung
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • We have obtained theoretical calibration curves to convert the amount of polarization into the strength of magnetic field, by a numerical calculation of radiation transfer for the polarized spectral line of FeI $6303{\AA}$. In our calculation, three kinds of atmospheric models (VAL-C, penumbra, umbra) have been used to make a proper calibration for an active region composed of quiet, penumbral and umbral areas. It was found that firstly, the results of our calculation depend highly on a kind of atmospheric model rather than on any other input parameters used in a model. Secondly, observed line profile showed m solar spectrum atlas proved to be very similar to the calculated profiles obtained by using a penumbra model. Finally, another method except this calibration curve should be developed to estimate correctly the distribution of magnetic field in solar active region from the observation of polarized spectral line.

  • PDF

SHORT-TERM CALIBRATION OF MTSAT-1R SOLAR CHANNEL USING DESERT TARGETS

  • Chun, Hyoung-Wook;Sohn, Byung-Ju
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.426-429
    • /
    • 2008
  • In this study, we propose the calibration algorithm for the solar channel (550 ${\sim}$ 900 nm) of MTSAT 1R which is the Japanese geostationary satellite launched on 26 Feb. 2005 and located at $140^{\circ}E$. We developed a method utilizing MODIS-derived BRDFs for the solar channel calibration over the bright desert area. Targets are selected based on the desert's brightness, spatial uniformity, temporal stability and spectral stability. The 6S model has been incorporated to account for directional effects of the surface using MODIS-derived BRDF parameters within the spectral interval in interest. Results based on the analysis for the period from November 2007 to June 2008 suggest that MTSAT-1R solar channel measurements have a low bias within 5%.

  • PDF

Color accuracy of imaging using color filters

  • Boher, P.;Leroux, T.;Patton, V. Collomb;Bignon, T.
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.7-16
    • /
    • 2012
  • In this paper, the problem concerning the color accuracy of imaging systems using color filters is examined. It is shown that the only solution to the problem is to build systems with the spectral response matching the CIE curves as closely as possible. If the spectral response does not closely match the CIE curves, it was demonstrated that calibration cannot solve the problem and will result in very unstable colorimeters. A practical solution that uses telecentric lenses on the sensor side in addition to dedicated color filters for each CCD detector is presented. For systems that closely match the CIE curves, an innovative method of improving the color accuracy based on the precise measurement of the spectral response is presented. The small discrepancies in the spectral response with regard to the CIE curves are corrected in different ways during the measurements. Finally, it is shown that the tristimulus calibration that is used for display measurement is very unstable for systems without CIE matching and is much more stable with systems that closely match the CIE curves.

Compositional Analysis of Naphtha by FT-Raman Spectroscopy

  • 구민식;정호일
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.159-162
    • /
    • 1999
  • Three different chemical compositions of total paraffin, total naphthene, total aromatic content in naphtha have been successfully analyzed using FT-Raman spectroscopy. Partial least squares (PLS) regression has been utilized to develop calibration models for each composition from Raman spectral bands. The PLS calibration results showed Blood correlation with those of gas chromatography (GC). Using PLS regression, the spectral information related to each composition has been successfully extracted from highly overlapped Raman spectra of naphtha.

Vicarious Radiometric Calibration of RapidEye Satellite Image Using CASI Hyperspectral Data (CASI 초분광 영상을 이용한 RapidEye 위성영상의 대리복사보정)

  • Chang, An Jin;Choi, Jae Wan;Song, Ah Ram;Kim, Ye Ji;Jung, Jin Ha
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.3-10
    • /
    • 2015
  • All kinds of objects on the ground have inherent spectral reflectance curves, which can be used to classify the ground objects and to detect the target. Remotely sensed data have to be transferred to spectral reflectance for accurate analysis. There are formula methods provided by the institution, mathematical model method and ground-data-based method. In this study, RapidEye satellite image was converted to reflectance data using spectral reflectance of a CASI hyperspectral image by using vicarious radiometric calibration. The results were compared with those of the other calibration methods and ground data. The proposed method was closer to the ground data than ATCOR and New Kurucz 2005 method and equal with ELM method.

Characteristics of Ocean Scanning Multi-spectral Imager(OSMI) (Ocean Scanning Multi-spectral Imager (OSMI) 특성)

  • Young Min Cho;Sang-Soon Yong;Sun Hee Woo;Sang-Gyu Lee;Kyoung-Hwan Oh;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.223-231
    • /
    • 1998
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-Purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a whisk-broom motion with a swath width of 800 km and a ground sample distance (GSD) of less than 1 km over the entire field-of-view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-orbit image data storage. The instrument also performs sun calibration and dark calibration for on-orbit instalment calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400 nm to 900 nm using a Charge Coupled Device (CCD) Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands after launch. The instrument performances are fully measured for 8 basic spectral bands centered at 412, 443, 490, 510, 555, 670, 765 and 865 nm during ground characterization of instalment. In addition to the ground calibration, the on-orbit calibration will also be used for the on-orbit band selection. The on-orbit band selection capability can provide great flexibility in ocean color monitoring.

STANDARIZING THE EXTRATERRESTRIAL SOLAR IRRADIANCE SPECTRUM FOR CAL/VAL OF GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Shanmugam, Palanisamy;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.86-89
    • /
    • 2006
  • Ocean color remote sensing community currently uses the different solar irradiance spectra covering the visible and near-infrared in the calibration/validation and deriving products of ocean color instruments. These spectra derived from single and / or multiple measurements sets or models have significant discrepancies, primarily due to variation of the solar activity and uncertainties in the measurements from various instruments and their different calibration standards. Thus, it is prudent to examine model-to-model differences and select a standard reference spectrum that can be adopted in the future calibration and validation processes, particularly of the first Geostationary Ocean Color Imager (GOCI) onboard its Communication Ocean and Meterological Satellite (COMS) planned to be launched in 2008. From an exhaustive survey that reveals a variety of solar spectra in the literature, only eight spectra are considered here seeing as reference in many remote sensing applications. Several criteria are designed to define the reference spectrum: i.e., minimum spectral range of 350-1200nm, based completely or mostly on direct measurements, possible update of data and less errors. A careful analysis of these spectra reveals that the Thuillier 2004 spectrum seems to be very identical compared to other spectra, primarily because it represents very high spectral resolution and the current state of the art in solar irradiance spectra of exceptionally low uncertainty ${\sim}0.1%.$ This study also suggests use of the Gueymard 2004 spectrum as an alternative for applications of multispectral/multipurpose satellite sensors covering the terrestrial regions of interest, where it provides spectral converge beyond 2400nm of the Thuillier 2004 spectrum. Since the solar-activity induced spectral variation is about less than 0.1% and a large portion of this variability occurs particularly in the ultraviolet portion of the electromagnetic spectrum that is the region of less interest for the ocean color community, we disregard considering this variability in the analysis of solar irradiance spectra, although determine the solar constant 1366.1 $Wm^{-2}$ to be proposed for an improved approximation of the extraterrestrial solar spectrum in the visible and NIR region.

  • PDF