Design and Calibration of Acousto-Optic Tunable Filter(AOTF) for Near Infrared Spectral Analysis
![]() |
You, Jang-Woo
(한국과학기술원 기계공학과)
Kim, Dae-Suk (한국과학기술원 기계공학과) Kwak, Yoon-Keun (한국과학기술원 기계공학과) Kim, Soo-Hyun (한국과학기술원 기계공학과) Lee, Yun-Woo (한국표준과학연구원 광도영상그룹) Hwang, In-Duk (삼성종합기술원) |
1 | Akis P. Goutzoulis, and Dennis R. Pape, 1994, 'Design and Fabrication of Acousto-Optic Devices,' Marcel Dekker, New York, p. 341 |
2 | Yoshiro Ohmachi, Naoya Uchida, and Nobukazu Niizeki, 1971, 'Acoustic Wave Propagation in TeO2 Single Crystal,' The Journal of the Acoustical Society of America, Vol. 51, No. 1, pp. 164-168 DOI |
3 | Kastelik, J. C., Gazalet, M. G., Bruneel, C. and Bridoux, E., 1993, 'Acoustic Shear Wave Propagation in Paratellurite with Reduced Spreading,' Journal of Applied Physics, Vol. 74, No.4, pp. 2813-2817 DOI ScienceOn |
4 | Kastelik, J. C., Gharbi, M. and Gazalet, M. G., 1998, 'Paratellurite:Propagation of the Slow Shear Wave in the (001) Plane. New Formulations for the Acoustic Velocity and Divergence,' Journal of Applied Physics, Vol. 84, No.2, pp. 671-674 DOI ScienceOn |
5 | Yano, T. and Watanabe, A., 1976, 'Acoustooptic TeO2 Tunable Filter using Far-off-axis Anisotropic Bragg Diffraction,' Applied Optics' Vol. 15, No.9, pp. 2250-2258 DOI |
6 | Naoya Uchida, 1971, 'Optical Properties of Single-Crystal Paratellurite (TeO2),' Physics Review B, Vol. 4, No. 10, pp. 3736-3745 DOI |
7 | Elliot S. Wachman, Wen-hua Niu, and Daniel L. Farkas, 1997, 'AOTF Microscope for Imaging with Increased Speed and Spectral Versatility,' Biophysical Journal, Vol. 73, No.3, pp. 1215-1222 DOI ScienceOn |
8 | Chang, I. C., 1974, 'Noncollinear Acousto-Optic Filter with Large Angular Aperture,' Applied Physics Letters, Vol. 25, No.7, pp. 370-372 DOI |
9 | Chang, I. C., 1975, 'Acoustooptic Devices and Applications,' IEEE Transactions on Sonics and Ultrasonics, Vol. su-23, No. 1, pp. 2-21 DOI ScienceOn |
10 | Georgi Georgiev, David A. Glenar, and John J. Hillman, 2002, 'Spectral Characterization of Acousto-Optic Filters used in Imaging Spectroscopy,' Applied Optics, Vol. 41, No. 1, pp. 209-217 DOI |
11 | Elliot S. Wachman, Wen-hua Niu, and Daniel L. Farkas, 1996, 'Imaging Acousto-Optic Tunable Filter with 0.35-micrometer Spatial Resolution,' Applied Optics, Vol. 35, No. 25, pp. 5220-5226 DOI |
12 | David A. Glenar, John J. Hillman, Babak Saif, and Jay Bergstralh, 1994, 'Acousto-Optic Imaging Spectropolarimetry for Remote Sensing,' Applied Optics, Vol. 33, No. 31, pp. 7412-7424 DOI |
13 | Romier, J., Selves, J. and Gastellu-Etchegorry, J., 1998, 'Imaging Spectrometer Based on an Acousto-Optic Tunable Filter,' Review of Scientific Instruments, Vol. 69. No.8, pp. 2859-2867 DOI ScienceOn |
![]() |