• Title/Summary/Keyword: spectacle

Search Result 147, Processing Time 0.024 seconds

Development of Cultural Products using Quilting Technique - Focused on the colored tread quilting technique - (누비기법을 응용한 문화상품 디자인 개발 연구 - 색실누비기법을 중심으로 -)

  • Oh, Ga-Young;Kim, Jong-Ho
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.10
    • /
    • pp.80-87
    • /
    • 2010
  • The purpose of this study is to develop cultural products containing Korean beauty with modern sense by applying quilting with dyed threat among Korean traditional quilting works. Quilting with dyed thread using various colored thread expresses curve, straight and oblique lines harmoniously, is mainly used to make household goods such as a pouch, a spectacle case and a quilting pocket and a circular pattern, a cross pattern and a geometric pattern are shown in this kind of quilting. As for sewing method, half backstitch and full backstitch are used, and products made by this method are pouches stuffing pads in cotton or silk and quilting it finely to make patterns with various colored threads of stuffing cotton between linings and spectacle cases, a packet of needles and case of spoon and chopsticks which give various feelings according to arrangement of colors. Design of cultural products by applying the beauty of curves of hanbok, sleave-seam of jeogori, trimming line of dangeui. We expect that various cultural products with Korean traditional beauty and modern convenience will be developed continually by introducing the artistic strength of quilting with dyed thread to practical life.

Comparison between Manifest Refraction and Cycloplegic Refractin for the First-time Spectacle Wearers (최초 안경착용자의 현성굴절검사(MR)와 조절마비굴절검사(CR)의 비교)

  • Kim, Hye-Ran;Choi, Sun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.145-149
    • /
    • 2008
  • Purpose: To study the difference between refractive errors obtained from manifest refraction (MR) and cycloplegic refraction (CR) in first-time spectacle wearers. To study the difference between manifest refractive errors and cycloplegic refractive errors in first-time spectacle wearers. Methods: From January 2002 to December 2002, manifest and cycloplegic refractions were carried out on the patients who visited an ophthalmology clinic for a spectacle prescription for the first-time. The patients were 509 male and 499 female patients aged between from 3 to 15 years old. Results: The cycloplegic refraction showed a less myopia and a more hyperopia compared with the non-cycloplegic refraction. The differences were more in female patients. The CR showed a less myopic and a more hyperopic refractive errors than the MR. The differences were more in female patients. The average results from a pre- and a post-cycloplegic refraction showed a reduction of -0.22D in male, and -0.20D in female for the myopic group. For the myopic group, the myopic refractive errors by MR were -0.22D in male and -0.20D in female higher than the refractive errors by CR. Hyperopic group showed an increase of +0.37D in male, and +0.56D in female. For hyperopic group the hypropic refractive errors by CR were +0.37D in male and +0.56D in female higher than the refractive errors by CR. This difference between the results of a preand a post-cycloplegic refraction was more if the patients were younger. This difference between refractive errors by MR and by CR showed the younger the more and the proportions of pseudo-myopia and or latent hyperopia were also higher with younger patents age. The amounts of with-the-rule astigmatism and the oblique astigmatism were increased for the post-cycloplegic refraction in the CR refraction. Simple astigmatism reduced, but there was no difference found in the amount of astigmatism. The prevalence of simple astigmatism reduced, but there was no difference in the amount of astigmatism. Conclusions: The difference between manifest refraction and cycloplegic refraction was more in younger group. The difference of refrative error between by MR and CR increases with ageing decrease. Pseudo-myopia and latent hyperopia was also found in the younger group. Simple astigmatism reduced after cycloplegic refraction, there was no difference found in the amount of astigmatism. The prevalence of simple astigmatism reduced, but there was no difference in the amount of astigmatism.

  • PDF

The Influence of the Front Surface Power and the Refraction Index on RMS Spot Diameter (전면 굴절력과 굴절률이 착락원의 크기에 미치는 영향)

  • Park, Seong-Jong;Shin, Cheol-Guen;Ju, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2003
  • To investigate the RMS SD(Root Mean Square Spot Diameter) in a back focal plane as the front surface power, the center thickness, and the refraction index vary, we use programs which are Cove V and LOSA 2.0, and consider a spectacle lens with back vertex power of -4.00D and diameter of 70 mm. We also consider the front surface power varied from 0.00 to 10.00D, the center thickness varied from 1.1 to 2.0 mm, and the indices which are $n_d$ = 1.498, 1.523, 1.586, and 1.660, respectively. As the front surface power increases the RMS SD in the back focal plane increase rapidly. When the refraction index increases, the RMS SD in the back focal plane decrease and the variation of RMS SD in the back focal plane decreases as the front surface power increases. When the center thickness of spectacle lens increases, the RMS SD in the back focal plane is constant and the edge thickness of that increases. We know from these results that the image in the back focal plane of a spherical spectacle lens improves as the front surface power increases and the refraction index decreases.

  • PDF

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Optical Evaluation of MR8 Material spectacle Lens with a New Method for the Analysis of Blue Light (새로운 청광 분석법을 적용한 MR8 안경재료의 광학적 시험 평가)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.413-420
    • /
    • 2018
  • Purpose : We present a novel method for the analysis of blue light applied by the analysis method of David L. with optical experiment and blue light by measuring the transmittance by dividing it by the refractive power in the spectacle lens made by MR8. Methods : The lenses of -8.00D, -7.00D, -6.00D, -5.00D, -4.00D, -3.00D, and 0.00D manufactured by MR8 being sold in the market, were selected. The transmittance was measured at the intervals of 5 nm from 200 to 1000 nm with UV-VIS Spectrophotometers (SolidSpec 3700), and they were in range of the blue light (380 to 500 nm) analyzed by a David L.'s analysis method. Results : All of the MR8 lenses selected for this study almost completely blocked at the UV range. A lens of -8.00D was measured as the lowest transmittance of 59.56% in the blue light area and low values were measured at the blue areas 1 and 2 according to the analysis of David L.In the infrared ray area, the transmittance of all lenses gradually decreased. The average value of the luminous transmittance was 23.67% ~ 26.33% and then gradually decreased from -4.00D. Conclusion : Applying the analysis of David L., a minimum of 41.28% and a maximum of 46.60% were measured at the blue light 1 area and a minimum of 87.30% and a maximum of 97.55% were measured at the blue light 2 area. A minimum of 86.83% and a maximum of 96.55% were measured at the blue light 3 area, and the average was 94%. The luminous transmittance of the -3.00D lens was 26.33%, which was the highest, and that -8.00D was 23.67%, which was the lowest.

A world-wide trends in structural concepts of footbridge (보도육교의 구조적인 컨셉에 대한 세계적인 추세)

  • Park, Sun-Woo
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.197-205
    • /
    • 2004
  • A vocabulary for a understanding bridge has a different scope. There are the urban setting, landscape, lightness, from minimum to maximum, continuity, material, erection, motion and dynamic. Aesthetics criteria of footbridge design are movement and grace, space and experiment, symbolism, iconic, sculpture, innovation, spectacle, lighting, gemetry and wonder. New structural concepts of pedestrian bridges are presented on examples of recently built structures. The main characteristics of described structures are appropriateness, humanity, structural efficiency and aesthetics.

  • PDF

The configuration and natural features of Woldun cave as tourism resources

  • Chung ryol hong;Jeong, Min-Chae
    • Journal of the speleological society of Korea
    • /
    • no.5
    • /
    • pp.25-36
    • /
    • 1997
  • The inside of Woldum cave has a complicated configuration with many dynamic aspects. The number of configurations and natural features of the ground discovered up to now is about 20. When we discuss the value of the potential tourism that the cave has, Woldun cave is a lime cave with resourceful value and tourism value, considering the size of cave and excellency of the spectacular sight. In addition, the large stalagmite's file lining in the inside of the cave is a magnificent spectacle. Therefore the Woldun cave, as a lime cave, is very important for tourism level as well as academic ones.

  • PDF

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.