• 제목/요약/키워드: specification limit

검색결과 134건 처리시간 0.023초

M-추정을 사용한 국방과학기술 수준조사 기술성장모형의 이상치 제거 (Elimination of Outlier from Technology Growth Curve using M-estimator for Defense Science and Technology Survey)

  • 김장헌
    • 한국군사과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.76-86
    • /
    • 2020
  • Technology growth curve methodology is commonly used in technology forecasting. A technology growth curve represents the paths of product performance in relation to time or investment in R&D. It is a useful tool to compare the technological performances between Korea and advanced nations and to describe the inflection points, the limit of improvement of a technology and their technology innovation strategies, etc. However, the curve fitting to a set of survey data often leads to model mis-specification, biased parameter estimation and incorrect result since data through survey with experts frequently contain outlier in process of curve fitting due to the subjective response characteristics. This paper propose a method to eliminate of outlier from a technology growth curve using M-estimator. The experimental results prove the overall improvement in technology growth curves by several pilot tests using real-data in Defense Science and Technology Survey reports.

SELFCON: An Architecture for Self-Configuration of Networks

  • Boutaba, Raouf;Omari, Salima;Singh Virk, Ajay Pal
    • Journal of Communications and Networks
    • /
    • 제3권4호
    • /
    • pp.317-323
    • /
    • 2001
  • Traditional configuration management involves complex labor-intensive processes performed by experts. The configuration tasks such as installing or reconfiguring a system, provisioning network services and allocating resources typically involve a large number of activities involving multiple network elements. The network elements may be associated with proprietary configuration management instrumentation and may also be spread across heterogeneous network domains thereby increasing the complexity of configuration management. This paper introduces an architecture for the self-configuration of networks (SELFCON). The proposed architecture involves a directory server, which is uses to maintain configuration information. The configuration information stared in the directory server is modeled using the standard DEN specification thereby allowing effective exchange of network, system and configuration management data among heterogeneous management domains. SELFCON associates configuration intelligence with the components of the network, rather than limit it to a centralized management station. The network elements are notified about related changes in configuration policies, based upon which, they perform self-configuration. SELFCON is able to provide automation of configuration management and also an effective unifying framework for enterprise management.

  • PDF

PID제어를 위한 실용적인 기준 모델 제안과 성능개선 (Proposal of Practical Reference-Model and It's Performance Improvement for PID Control)

  • 허정규;양경욱
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.66-72
    • /
    • 2007
  • This study proposed new method to decide the reference model necessary for design PID controller. In generally, control design problems using the reference model have the following two factors. One factor is that numerical model of the controlled system can be obtained extremely, and the other is that specification for the closed-loop dynamic performance is pure moderate. Therefore, the control design procedure is essentially based on the partial reference model matching which offers a reasonable method to simplify the design and the controller configuration under the controlled system uncertainty. ITAE(Integral of time-multiplied absolute error) performance index and Kitamori method etc. which were used a reference model method had a limit to settling time and rising time of reference model that it arrived to steady state response according to the controlled system. On this study, if it only knew peak time of overshoot and settling time by measurement signal of the controlled system, it can be made the reference model easily. We proposed new method to improve performance index of the reference model superior to existing reference model index and illustrate the numerical simulation results to show the effectiveness of proposed control method design.

  • PDF

EN50128 SIL4 소프트웨어 프로세스 ISA 인증 사례 연구 (Study on ISA's assessment to software process for EN50128 SIL4)

  • 조치환;강찬용;황진호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.838-849
    • /
    • 2010
  • It is inevitable to control the systematic failure to obtain the software safety integrity of embedded software installed in rolling stock. Because it is not possible to assess systematic failure integrity by quantitative methods, SILs are used to group documentation, methods, tools and techniques throughout software development lifecycle which, when used effectively, are considered to provide an appropriate level of confidence in the realization of a system to a stated integrity level. Normally, safety approval process is through generic product, generic application and specification application for. For safety approval on generic application of software based system, it is required to apply the certified software processes from the planning stage for the assigned SIL. As such, we will develop project specific application with high safety integrity within time limit of contractual delivery schedule through software assessment to the modified area with the re-use of certified software module and documentation. At this point, Hyundai Rotem has developed software processes applicable to support SIL 4 based on EN50128 which was assessed and certified by TUV SUD. This paper introduces the Hyundai Rotem's detailed approach and prospective action to achieve software safety integrity level.

  • PDF

고강도 휨재의 강도와 연성에 관한 실험적 연구 (An Experimental Study on the Strengh and Ductility of High-Strength Flexural Members)

  • 이승준
    • 한국강구조학회 논문집
    • /
    • 제13권1호
    • /
    • pp.19-28
    • /
    • 2001
  • 본 연구에서는 강구조 휨재의 강도와 연서이을 실험적인 방법으로 조사하였다. 휨재의 성능평가와 관련하여 총 9개의 시험체를 제작하고 실험을 실시하였다. 4개의 시험체는 구조용 강재 SM490을 이용하여 제작하였으며 5개의 시험체 제작에는 구조용 강재SM570이 이용하였다. 실험결과는 시험체의 강도와 연성에 초점을 두고 분석하였다. 실험결과는 모든 시험체가 현행 한계상태 설계기준의 공칭휨강도를 평균 1.22배 초과하는 충분한 휨강도를 보유하는 것으로 나타났다. 그러나 강재 SM570으로 제작된 콤팩트 단면의 시험체는 요구되는 연성을 나타내지 못하였다. 강재 SM570의 항복비가 0.9이었으며 이러한 항복비가 연성이 부족한 원인으로 추정되었다.

  • PDF

대안교육 지역특성화학교의 시설 및 이용현황 조사연구 (A Study on the Architectural Facilities Utilization of Regional Specialized Schools for Alternative Education)

  • 정진주
    • 한국농촌건축학회논문집
    • /
    • 제9권3호
    • /
    • pp.73-82
    • /
    • 2007
  • Ministry of Education and Human Resources presented on December, 2006, 'Alternative school establishment and operation regulation' of contents that can be recognized attainments in scholarship because is authorized if alternative schools fulfill fixed condition. Even though, one time, it was true that several opinions which try to limit to adaptation school of person disqualified for school, thus, various discussion and efforts that specialized school for alternative education does to grow are appearing. However, the expectation which a lot of non authorized schools will apply is not so high because specialized school for alternative education will be controlled in free curriculum and school operation that have been administered and can not be guaranteed school's sell-regulation if acquire legal authorization. Under such social and educational background I surveyed present condition, law, system, literature investigation of existing study, Japanese system and example and authorized two sample specification schools etc. through 'A Basic Study on the Optimum Facilities Criteria Modeling of Regional Specialized Schools for Alternative Education(2006. 10)'. This study was preceded the succession and I visited 17 schools that permit investigation opening of schools among 29 that is authorized until present. So I try to find out architectural planning criteria to activate specialized school for alternative education more through analyzing school's general present condition, establishment idea, operation and specialized education plan, facilities present condition and characteristic.

  • PDF

경유 대체연료로서 수첨바이오디젤의 윤활 특성 연구 (Lubricity Characterization of Hydrogenated Biodiesel as an Alternative Diesel Fuel)

  • 김재곤;전철환;임의순;정충섭
    • Tribology and Lubricants
    • /
    • 제28권6호
    • /
    • pp.321-327
    • /
    • 2012
  • Paraffin bio-based hydrotreated biodiesel(HBD) is originated from vegetable oil(the process can also be applied to animal fat) with the the chemical structure $C_nH_{2n+2}$. In the number of process of the oil or fat, the hydrogenation is significantly important to create a bio-based diesel fuel. This study is focused on lubricity characteristics of BTL diesel blends to use alternative diesel fuel in Korea. The BTL diesel are blended the different volume ratios (HBD 5(5 vol.% HBD - 95 vol.% diesel), HBD 10, HBD 20, HBD 30, HBD 40 and HBD 50. HBD with paraffin compounds showed a very high centane number, low sulfur content and free aromatic compound. Especially, the wear scar of HBD showed poor lubricity compared to automotive diesel due to the fuel composition, low sulfur content and free aromatic compound. Also, the lubricity specification of automotive diesel with different six HBD blends is within the limit by the Korean standards. Finally, HBD as an alternative diesel fuel is challengeable in transportation sector of Korea.

Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

  • Baek, Kwang Ki;Park, Chung Seo;Kim, Ki Hong;Chung, Mong Kyu;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.27-32
    • /
    • 2006
  • One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities.

Measurement of the Moderator Temperature Coefficient of Reactivity for Pressurized Water Reactors

  • Yu, Sung-Sik;Kim, Se-Chang;Na, Young-Whan;Kim, H. S.;J. Y. Doo;Kim, D. K.;S. W. Long
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.488-499
    • /
    • 1997
  • The measurements of the moderator temperature coefficient (MTC) are performed to demonstrate that the calculational model produces results that are consistent with the measurements. Since negative MTC is also a technical specification value that may limit the cycle length, it is important to measure it as accurately as possible. In this report, preferred choice of test method depending on the time in cycle, best power indication and temperature definition in MTC calculation were determined based on the MTC test results taken during initial startup testing and at 2/3 cycle burnup in the Yonggwang nuclear power plant. The results show that the ratio and rodded methods provided good agreement with the predictions during initial startup testing. However, near end-of-cycle the depletion method gives better results, and so is suggested to be used in the MTC measurements at 2/3 cycle burnup. The use of primary Delta T power as a power indicator in the MTC calculations is highly advisable since it responds with good consistent results very quickly to changes unlike secondary calorimetric power. For the appropriate temperature definitions used in the MTC calculations, it is considered that the arithmetic average temperature measured simply by inlet and outlet thermocouples is preferred. Although volumetric average temperature provides better results, the improvement is not sufficient to compensate for the simplicity of calculations by arithmetic average temperature.

  • PDF

Modification of Reference Temperature Program in Reactor Regulating System

  • Yu, Sung-Sik;Lee, Byung-Jin;Kim, Se-Chang;Cheong, Jong-Sik;Kim, Ji-In;Doo, Jin-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.404-410
    • /
    • 1998
  • In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold leg temperature was very close to the technical specification limit of 298$^{\circ}C$ during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended.

  • PDF