• Title/Summary/Keyword: specific discharge

Search Result 608, Processing Time 0.028 seconds

Determination of Model Parameters of Surface Cover Materials in Evaluation of Sediment Reduction and Its Effects at Watershed Scale using SWAT (토양유실 저감을 위한 지표피복 저감효과 변수 결정 및 SWAT 모형 유역단위 효과 분석)

  • Kum, Donghyuk;Jang, Chun Hwa;Shin, Min Hwan;Choi, Joong-Dae;Kim, Bomchul;Jeong, Gyo-Cheol;Won, Chul Hee;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.923-932
    • /
    • 2012
  • The purpose of this study was to determine parameters of surface cover materials and evaluation the effects on runoff and sediment reductions with rice straw mat with PAM at watershed scale using the SWAT model. In this study, 1) regression equation of CN for rice straw mat + PAM using SCS curve number method was developed, 2) the USLE P factor, being able to reflect simulation of rice straw mat + PAM in the agricultural field, was estimated for various slope scenarios with VFSMOD-w. Then regression equation for CN and USLE P factor were used as input data in the SWAT model. Assuming rice straw mat + PAM is applied to radish and potato fields, occupying 24% of agricultural fields at the study watershed. Result of direct runoff without rice straw mat + PAM was $65,964,368\;m^3,$ with rice straw mat + PAM, direct runoff was $65,637,336\;m^3$, $327,031.8\;m^3$ reductions compared without it. Also, result of sediment without rice straw mat + PAM was 163,531 ton, with rice straw mat + PAM, sediment was 84,779 ton, 78,752 ton reduction compared without it. This analysis showed that about 48% sediment reductions would be expected with rice straw mat + PAM. As shown in this study, rice straw mat + PAM would be used as an efficient site-specific BMPs to reduce runoff and sediment discharge from field.

A Study of Adenovirus Pneumonia: Early Summer Outbreak in 1996 (1996년 초여름에 유행한 Adenovirus폐렴의 검토)

  • Kim, Chang Keun;Chung, Churl Young;Kim, Jung Suk;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.3 no.2
    • /
    • pp.145-153
    • /
    • 1996
  • The incidence of Adenovirus(AV) pneumonia in children is estimated at 8%. Long-term complications reported with type 7 include hyperleucent lung syndrome, bronchiolitis obliterans and may require several months to recover. We reviewed 8 case of AV pnemonia confirmed by AV culture and sero-diagnosis among selected 19 AV pneumonia suspicious cases who were admitted to the Sanggye Paik Hospital of Inje University due to clinical pneumonia from May to July 1996. From 19 children, nasal aspirates or trachial aspirates were collected: viral agents were detected by virus isolation and virus antigen was detected by indirect immunofluorescent staining. Serologic diagnosis for type-specific AV antibody was done by neutralisation test. The results are as follows: 1) Age of the patients ranged from 6 months to 47 months with a mean of $24{\pm}9$ months. 6 were male and 2 were female(M:F= 3:1). 2) Monthly distribution showed 4 cases on June, 2 cases on May and July, respectively. 3) The mean duration of admission was 20.4 days and mean duration of fever was 11.3 days 4) Peripheral leukocyte counts were elevated in 4 cases(50%) and findings of shift to left were showed in 4 cases(50%) and serum aminotransferase activities were elevated in 6 case(75%). 5) Radiologic findings include linear and streaky infiltration(1/8 cases), patchy and lobar consolidation (7/8 cases), pleural effusion(2/8 cases) and hyperleucency was seen in 3/8 cases at time of admission and increased to 6/8 cases on hospital discharge. 6) The AV serotypes were type 7, type 3, and type 1. 7) Oxygen supply was done in 4 cases(50%) and all 8 patients include 2 cases of type 7 treated with artificial ventilator were survived. In conclusion, the serotypes of AV pneumonia outbreaks in early summer of 1996 were type 7, 3, 1 and, as showed severe clinical course, continued follow up surveillance is necessary to the long term pulmonary complications.

  • PDF

Assessment of Technology-Based Industrial Wastewater Effluent Limitations and Standards for the Application in Domestic Industries ( I ) : Case-study, Applying TBELs in US (처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구( I ) : 미국 TBELs 적용사례 검토)

  • Kim, Kyeongjin;Son, Daehee;Her, Jin;Kim, Kwangin;Kwon, Osang;Yeom, Ictae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Technology-Based Effluent Limitations (TBELs) is a permit limits for a pollutant that is based on the capability of a treatment technology to reduce the pollutant to a certain concentration. Widely practiced for regulations of industrial wastewater in US, TBELs has been accepted as an effective means that can achieve balanced goals between complete elimination of pollutants discharge and economic feasibility for industries. The review of TBELs application in US and the applicability of TBELs to the domestic industry categories was given in three papers. In the first paper, the development and practices of TBELs in US were reviewed including case studies. The developments of TBELs in US in the four major categories, the metal products & machinery, the petroleum refining, the porcelain enameling and the meat & poultry products were reviewed. The applicability of TBELs to the domestic industrial categories was also assessed. In the second paper, the pollution loads analysis for domestic industrial wastewater was conducted based on risk assessment indicator using Toxic Weighting Factors (TWFs). This is an essential part to determine the priority of TBELs application for the domestic industrial categories. In the last paper, the application of TBELs to the domestic industries was demonstrated through a case-study for the pulp/paper/paperboard category. Direct application of TBELs of US into the Korean regulation system may not be desirable because the specific goals and the environment for the regulations for the two countries may not be identical. For example, unlike US, Korea does not adopt the individual permit system for pollution sources. However, among the unproductive and exhaustive controversies over the uniform regulations regardless of the industrial categories in Korea, the introduction of the principles of TBELs are inevitable and more extensive study for applications of TBELs optimized for Korean regulation system will be necessary.

Land-use Enhancement Benefit According to Flood Safety (치수안전도에 따른 토지이용의 편익 분석)

  • Lee, Jin Ouk;Kim, Hung Soo;Shim, Myung Pil;Choi, Seung An
    • Journal of Wetlands Research
    • /
    • v.6 no.4
    • /
    • pp.45-57
    • /
    • 2004
  • This study analyzed the effect of land-use enhancement benefits with the flood safety which it is not quantified in the flood damage analysis, Korea. The land-use enhancement benefits mean the enhancement of land-use value according to the rise of flood safety of the protected area by the flood control projects and we performed the analysis of land-use enhancement benefits with the publicly announced land price which can objectively represent the land-use value of a specific area. We verified the statistical significance of the floating rate of land price according to the effects of flood control projects and the characteristics of a river through the analysis of variance. As a result of the verification, the increase of land-use value was represented by the net annual average floating rate of land price. The flood safety was classified as flood damage potential and flood prevention capacity. The flood damage potential was classified according to the rate of urbanization and flood prevention capacity was represented by the conditional annual non-exceedance probability obtained from the frequency analysis with uncertainty for the flood discharge. The study areas were small urban cities and we calculated the conditional annual non-exceedance probabilities of 200-year flood event for the levees constructed with the conditions of 10- and 50-year design frequency. The result was shown that the net annual average floating rate of land price would be raised nearly 5 times for 10%-increase of the conditional annual non-exceedance probability in small city areas.

  • PDF

Assessment of Biological Toxicity Monitoring in Water Using Sulfur Oxidizing Bacteria (하천수의 생태독성을 파악하기 위한 황산화미생물의 이용가능성 평가)

  • Kang, Woo-Chang;Oh, Sang-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.2
    • /
    • pp.170-174
    • /
    • 2012
  • BACKGROUND: Inappropriate discharge of wastewaters and industrial effluents are becoming detrimental to the aquatic environment. The presence of toxic substances on wastewaters can be detected by physicochemical and biological methods. However, physicochemical methods do not give any information about biological toxicity. Therefore, in this study we tried to detect the presence of toxic substance on waters using sulfur-oxidizing bacteria (SOB) as a bioassay. MATERIALS AND RESULTS: The SOB biosensor was first stabilized using synthetic stream water and operated in both continuous and semi-continuous mode. When the SOB biosensor was operated in continuous mode, the effluent electrical conductivity (EC) stabilized at~1.72 dS/m. While in the case of semi-continuous, the EC stabilized at~0.6 dS/m. The SOB system was also operated at different reaction times to ascertain the shortest reaction time for monitoring the toxicity. Finally, the SOB biosensor was fed with nitrite as toxic substance. When 5 mg/L of nitrite was added to the SOB system, the EC decreased immediately. However, the EC recovered after few cycle. CONCLUSION: This study shows that the SOB biosensor can be used as warning system to protect aquatic environment from hazardous materials. Although SOB biosensor can not give specific information about the toxic substances, it can assess whether the water is toxic or not.

Electrochemical Performances of Acid-Treated and Pyrolyzed Cokes According to Acid Treatment Time (산처리 시간별 산화 코크스와 열분해 코크스의 전기화학적 거동)

  • Kim, Ick-Jun;Yang, Sunhye;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.407-412
    • /
    • 2008
  • As an activation procedure, in this study, the oxidation treatment of needle cokes with a dilute nitric acid and sodium chlorate $(NaClO_3)$, combined with heat treatment, was attempted. The structures of acid-treated and pyrolyzed coke were examined with XRD, FESEM, elemental analyzer, BET, and Raman spectroscopy. The behavior of double layer capacitance was investigated with the analysis of charge and discharge. The structure of needle coke treated with acid was revealed to a single phase of (001) diffraction peak after 24 h. On the other hand, thecoke oxidized by heat treatment was reduced to a graphite structure of (002) at $300^{\circ}C$. The distorted graphene layer structure, derived from the process of oxidation and reduction of the inter-layer, makes the pores by the electric field activation at the first charge, and generates the double layer capacitance from the second charge. The cell using pyrolyzed coke with 24 h acid treatment and $300^{\circ}C$ heat treatment exhibited the maximum capacitance per weight and volume of 33 F/g and 30 F/mL at the two-electrode system in the potential range of 0~2.5 V.

Dynamics of High Turbid Water Caused by Heavy Rain of Monsoon and Typhoon in a Large Korean Reservoir (Andong Reservoir) (인공호에서 몬순과 태풍 강우에 의한 고탁수층의 이동과 소멸특성)

  • Park, Jung-Won;Shin, Jae-Ki;Lee, Hee-Moo;Park, Jae-Chung
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.1 s.110
    • /
    • pp.105-117
    • /
    • 2005
  • During the period of heavy rain from 2002 to 2004, the characteristics of the inflow, temporal and spatial fluctuations of high turbid water according to thermal stratification were studied on the Andong Reservoir which is the largest artificial lake in the Nakdong River basin, Korea. Thermal stratification was formed in June. Its structure determined to the pathway of inflowing turbid water and has affected by the transportation of high turbid water. Regardless of the time and amount of inflow, the high turbid water showed the shape of underflow at the riverine zone, separated from the bottom at the transition zone and moved to the lacustrine zone with the shape of density current. The plunging point depended on the time and amount of inflow. The distributions of thermal stratification and DO concentrations were changed by inflowing discharge. Two thermoclines and minimum DO layers were found out existing at metalimnion in a specific time, respectively. The layer of high turbid water which formed with the thickness of 20 m at the maximum below the depth of 15 m moved toward dam. Not settled to the bottom, the newly formed layer was discharged through the intake-outlet and dispersed into all layers by the circulation in the fall.

The Synthesis and the Electrochemical Properties of Al Doped $V_2O_5$ (Al이 도핑된 오산화바나듐의 합성 및 전기화학적 특성)

  • Park, Heai-Ku;Joung, Ok-Young;Lee, Man-Ho
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.491-495
    • /
    • 2005
  • Vanadium pentoxide xerogels with a doping ratio of $Al/V_2O_5$ ranging from 0.01 to 0.05 were synthesized by doping Al into $V_2O_5$ xerogel via the sol-gel process. By using the synthesized $Al_xV_2O_5$, the $Li/Al_xV_2O_5$ cells were assembled to investigate the chemical and electrochemical properties. Surface morphology of the $Al_xV_2O_5$ xerogel showed an anisotropic corrugated sheet-like matrix, and the interlayer distance was about $11.5{\AA}$. The IR spectra of the $Al_xV_2O_5$ revealed that the doped Al was coordinated to the vanadyl group in $V_2O_5$. The $Al_xV_2O_5$ xerogels showed enhanced reversibility and energy density compared with the $V_2O_5$ xerogel. The specific capacity of the $Al_{0.05}V_2O_5$ xerogel was more than 200 mAh/g at 10 mA/g discharge rate, and cycle efficiency was about 90% after the 31st cycling test between 1.9 V and 3.9 V.

Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel (극저온액체 저장용기에서 열전도 차폐단의 영향)

  • Kim, S.Y.;Kang, B.H.;Choi, H.J.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 1998
  • An experimental study on effect of vapor-cooled heat stations in a 5.5 liter cryogenic vessel has been performed. The cryogenic vessel is made of stainless steel of thickness of 1mm and insulated by the combined insulation of vacuum, MLI(multi-layer insulation) and vapor-cooled radiation shield. Vapor-cooled heat stations are also constructed based on the 1-dimensional thermal analysis to reduce the heat inleak through a filling tube. Thermal analysis indicates that the vapor-cooled heat stations can substantially enhance the performance of vessel for cryogenic fluids with high $C_p/h_{fg}$ where $C_p$ the specific heat and $h_{fg}$ the heat of vaporization, such as $LH_2$ and LHe. The experimental results for $LN_2$ shows that the total heat inleak into inner vessel consists of 14% radiation and 86% conduction through the filling tube. Therefore, it is expected that the conduction heat in leak of the vessel for high $C_p/h_{fg}$ cryogenic fluids can be significantly reduced. powders. The amount of copper coating was 20wt%. In order to examine corrosion behavior of the electrodes, the corrosion current and the current density, in 6M KOH aqueous solution after removal of oxygen in the solution, were measured by potentiodynamic and cyclic voltamo methods. The results showed that Co in the alloy increased corrosion resistance of the electrode whereas Ni decreased the stability of the electrode during the charge-discharge cycles. The electrode used Si sealant as a binder showed a lower corrosion current density than the electrode used PTFE and the electrode used Cu-coated alloy powders showed the best corrosion resistance.

  • PDF

3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir with ELCOM-CAEDYM (ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링)

  • Chung, Se-Woong;Lee, Heung-Soo;Ryoo, Jae-Il;Ryu, In-Gu;Oh, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1187-1198
    • /
    • 2008
  • Many reservoirs in Korea and their downstream environments are under increased pressure for water utilization and ecosystem management from longer discharge of turbid flood runoff compared to a natural river system. Turbidity($C_T$) is an indirect measurement of water 'cloudiness' and has been widely used as an important indicator of water quality and environmental "health". However, $C_T$ modeling studies have been rare due to lack of experimental data that are necessary for model validation. The objective of this study is to validate a coupled three-dimensional(3D) hydrodynamic and particle dynamics model (ELCOM-CAEDYM) for the simulation of turbid density flows in stratified Daecheong Reservoir using extensive field data. Three different groups of suspended solids (SS) classified by the particle size were used as model state variables, and their site-specific SS-$C_T$ relationships were used for the conversion between field measurements ($C_T$) and state variables (SS). The simulation results were validated by comparing vertical profiles of temperature and turbidity measured at monitoring stations of Haenam(R3) and Dam(R4) in 2004. The model showed good performance in reproducing the reservoir thermal structure and propagation of stream density flow, and the magnitude and distribution of turbidity in the reservoir were consistent with the field data. The 3D model and turbidity modeling framework suggested in this study can be used as a supportive tool for the best management of turbidity flow in other reservoirs that have similar turbidity problems.