• Title/Summary/Keyword: sparger

Search Result 37, Processing Time 0.024 seconds

THERMAL-HYDRAULIC TESTS AND ANALYSES FOR THE APR1400'S DEVELOPMENT AND LICENSING

  • Song, Chul-Hwa;Baek, Won-Pil;Park, Jong-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.299-312
    • /
    • 2007
  • The program on thermal-hydraulic evaluation by testing and analysis (THETA) for the development and licensing of the new design features in the APR1400 (Advanced Power Reactor-1400) is briefly introduced with a presentation on the research motivation and typical results of the separate effect tests and analyses of the major design features. The first part deals with multi-dimensional phenomena related to the safety analysis of the APR1400. One research area is related to the multidimensional behavior of the safety injection (SI) water in a reactor pressure vessel downcomer that uses a direct vessel injection type of SI system. The other area is associated with the condensation of steam jets and the resultant thermal mixing in a water pool; these phenomena are relevant to the depressurization of a reactor coolant system (RCS). The second part describes our efforts to develop new components for safety enhancements, such as a fluidic device as a passive SI flow controller and a sparger to depressurize the RCS. This work contributes to an understanding of the new thermal-hydraulic phenomena that are relevant to advanced reactor system designs; it also improves the prediction capabilities of analysis tools for multi-dimensional flow behavior, especially in complicated geometries.

Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions (고온 고압 조건하의 기포유동층 반응기에서의 입자 마모특성)

  • Moon, Jong-Ho;Lee, Dong-Ho;Ryu, Ho-Jung;Park, Young Cheol;Lee, Jong-Seop;Min, Byoung-Moo;Jin, Gyoung Tae
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.359-366
    • /
    • 2014
  • Attrition characteristics of PKM1-SU particles, $CO_2$ absorbents for pre-combustion $CO_2$ capture process, and FCC particles, catalytic particles for hydro cracking of crude oil, were investigated at high temperature and high pressure conditions. Particle attrition tests were executed at various kinds of temperature ($0-400^{\circ}C$) and pressure (0-20 bar) conditions in a cylinder type bubbling fluidized bed with 15.1 cm diameter, 120 cm height and 1 mm orifice-sparger tube. Attrited particles before and after tests were analyzed by BET, optical microscopy, and particle size analyzer. Effects of bed material height (solid inventory) and steam injection were also verified by using ASTM D5757-95, conventional attrition test method.

Absorption Characteristics of Sulfur Dioxide in Jet Bubbling Reactor (가스분사반응기에서의 SO2 흡수 특성)

  • Choi, Byung-Sun;Park, Seung-Soo;Kim, Yung-whan
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.836-842
    • /
    • 1994
  • The optimum design conditions of gas sparger pipe and the effects of operating variables on $SO_2$ removal efficiency have been examined in Jet Bubbling Reactor. Geometry of gas sparser pipe of Jet Bubbling Reactor is a very important factor to obtain a effective gas-liquid contact. Test results revealed that Reynolds numbers at sparger and slot have to be kept greater than 12,000 identically at a given gas velocity. $SO_2$ removal efficiency was a function of ${\Delta}P$, pH, inlet $SO_2$ concentration and particle size of limestone and was more sensitive to the change of ${\Delta}P$ than to the changes of others. The ${\Delta}P$ of at least 230mmAq must be maintained to acheive the above 90% $SO_2$ removal at pH of 4.0 which is considered as adequate operating pH. Higher $SO_2$ removal efficiency was obtained even at lower pH ranges, which resulted from the complete oxidation of the absorbed $SO_2$ to sulfates by adding air and consequently from the reduction of $SO_2$ equillibrium partial pressure in the gas-liquid interface The 99.5% of the limestone utilization was attained in pH range from 3.0 to 5.0 with regardless to the particle size of limestone employed.

  • PDF

Characteristics of Air Stripping for Recycling of Ammonia in Aqueous Solutions (수용액중 암모니아 Recycling을 위한 Air Stripping 특성에 관한 연구)

  • Lee Hwa-Yaung;Oh Jong-Kee;Kim Sung-Gyu
    • Resources Recycling
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 2003
  • A study on the characteristics of ammonia desorption from aqueous solutions has been performed by air stripping as the first stage of ammonia recycling for the preparation of ammonium sulfate from it. For air stripping experiments, a stripping column made with acrylic tube of 40 mm diameter was employed and compressed air was injected into solutions through air sparger equipped at the bottom of stripping column. As a result of experiments, the stripping efficiency was increased with the aqueous pH and it was found that the appropriate pH for air stripping of ammonia was between pH 10 and 12. As far as the effect of air flow rate on ammonia stripping was concerned, ammonia stripping was not proportional to the air flow rate although it was affected by the air flow rate to some extent. Moreover, when more than 20 cm of water height was maintained, total ammonia desorbed from solution was not varied with the water height. Stripping temperature was also found to play an important role in ammonia desorption and about 90fo of initial ammonia was desorbed in 14 hours at pH 12.8 and at $60^{\circ}C$ Finally, it was believed that stripping temperature as well as the aqueous pH was one of the most important factors in air stripping of ammonia.

A CFD ANALYSIS FOR THERMAL MIXING IN A SUBCOOLED WATER UNDER TRANSIENT STEAM DISCHARGE CONDITIONS (과도상태 증기제트 방출시 과냉각수조 내의 열혼합 해석)

  • Kang H.S.;Kim Y.S.;Chun H.G.;Song C.H.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.8-18
    • /
    • 2006
  • A CFD benchmark calculation for a steam blowdown test was performed for 30 seconds to develop the methodology of numerical analysis for the thermal mixing between steam and subcooled water. In the CFD analysis, the grid model simulating the sparger and the IRWST pool were developed by the axisymmetric condition and then the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. Thermal mixing phenomenon in the subcooled water tank was treated as an incompressible flow, a free surface flow between the air and the water, a turbulent flow, and a buoyancy flow. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. The commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behavior reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted.

Study of Air Clearing during Severe Transient of Nuclear Reactor Coolant System (원자로 사고 또는 과도상태시 공기방출현상에 대한 연구)

  • Bae Yoon Yeong;Kim Hwan Yeol;Song Chul-Hwa;Kim Hee Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.835-838
    • /
    • 2002
  • An experiment has been performed using a facility, which simulates the safety depressurization system (SDS) and in-containment refueling water storage tank (IRWST) of APR1400, an advanced PWR being developed in Korea, to investigate the dynamic load resulting from the blowdown of steam from a steam generator through a sparser. The influence of the key parameters, such as air mass, steam pressure, submergence, valve opening time, and pool temperature, on frequency and peak toads was investigated. The blowdown phenomenon was analyzed to find out the real cause of the initiation of bubble oscillation and discrepancy in frequencies between the experiment and calculation by conventional equation for bubble oscillation. The cause of significant damping was discussed and is presumed to be the highly tortuous flow path around bubble. The Rayleigh-Plesset equation, which is modified by introducing method of image, reasonably reproduces the bubble oscillation in a confined tank. Right after the completion of air discharge the steam discharge immediately follows and it condenses abruptly to provide low-pressure pocket. It may contribute to the negative maximum being greater than positive maximum. The subsequently discharging steam does not play as at the driving force anymore.

  • PDF

Development of a Dedicated Model for a Real-Time Simulation of the Pressurizer Relief Tank of the Westinghouse Type Nuclear Power Plant (웨스팅하우스형 원자력발전소 가압기 방출 탱크의 실시간 시뮬레이션을 위한 전문모델 개발)

  • 서재승;전규동
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.2
    • /
    • pp.13-21
    • /
    • 2004
  • The thermal-hydraulic model ARTS which was based on the RETRAN-3D code adopted in the domestic full-scope power plant simulator which was provided in 1998 by KEPRI. Since ARTS is a generalized code to model the components with control volumes, the smaller time-step size should be used even if converged solution could not get in a single volume. Therefore, dedicated models which do not force to reduce the time-step size are sometimes more suitable in terms of a real-time calculation and robustness. In the case of PRT(Pressurizer Relief Tank) model, it is consist of subcooled water in bottom and non-condensable gas in top. The sparger merged under subcooled water enhances condensation. The complicated thermal-hydraulic phenomena such as condensation, phase separation with existence of non-condensable gas makes difficult to simulate. Therefore, the PRT volume can limit the time-step size if we model it with a general control volume. To prevent the time-step size reduction due to convergence failure for simulating this component, we developed a dedicated model for PRT. The dedicated model was expected to provide substantially more accurate predictions in the analysis of the system transients. The results were resonable in terms of accuracy, real-time simulation, robustness and education of operators, complying with the ANSI/ANS-3.5-1998 simulator software performance criteria and RETRAN-3D results.

  • PDF

Effects of Hydrocarbon Additions on Gas-liquid Mass Transfer Coefficients in Biphasic Bioreactors

  • Silva, Teresa Lopes da;Calado, Vitor;Silva, Nadia;Mendes, Rui L.;Alves, Sebastiao S.;Vasconcelos, Jorge M.T.;Reis, Alberto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.3
    • /
    • pp.245-250
    • /
    • 2006
  • The effects of aliphatic hydrocarbons (n-hexadecane and n-dodecane) on the volumetric oxygen mass transfer coefficient $(k_L\;a)$ were studied in flat alveolar airlift reactor and continuous stirred tank reactors (CSTRs). In the flat alveolar airlift reactor, high aeration rates (>2vvm) were required in order to obtain efficient organic-aqueous phase dispersion and reliable $k_La$ measurements. Addition of 1% (v/v) n-hexadecane or n-dodecane increased the $k_La$ 1.55- and 1.33-fold, respectively, compared to the control (superficial velocity: $25.8{\times}10^{-3}m/s$, sparger orifice diameter: 0.5 mm). Analysis of the gas-liquid interfacial area a and the liquid film mass transfer coefficient $k_L$ suggests that the observed $k_La$ increase was a function of the media's liquid film mass transfer. Addition of 1% (v/v) n-hexadecane or n-dodecane to analogous setups using CSTRs led to a $k_La$ increase by a factor of 1.68 and 1.36, respectively (superficial velocity: $2.1{\times}10^{-3}m/s$, stirring rate: 250 rpm). These results propose that low-concentration addition of oxygen-vectors to aerobic microbial cultures has additional benefit relative to incubation in purely aqueous media.