Effects of deck's width-to-depth ratios and turbulent flows on the aerodynamic behaviors of long-span bridges

  • Lin, Yuh-Yi;Cheng, Chii-Ming;Lan, Chao-Yuan
    • Wind and Structures
    • /
    • 제6권4호
    • /
    • pp.263-278
    • /
    • 2003
  • This study investigates the effects of a bridge deck's width-to-depth (B/H) ratio and turbulence on buffeting response and flutter critical wind speed of long-span bridges by conducting section model tests. A streamlined box section and a plate girder section, each with four B/H ratios, were tested in smooth and turbulent flows. The results show that for the box girders, the response increases with the B/H ratio, especially in the vertical direction. For the plate girders, the vertical response also increases with the B/H ratio. However, the torsional response decreases as the B/H ratio increases. Increasing the B/H ratio and intensity of turbulence tends to improve the bridge's aerodynamic stability. Experimental results obtained from the section model tests agree reasonably with the calculated results obtained from a numerical analysis.

전단경간비에 따른 고강도 SFRC보의 성능 평가 (Capacity Evaluation of High Strength SFRC Beams according to Shear Span to Depth Ratio)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.76-83
    • /
    • 2014
  • 본 연구의 목적은 고강도 SFRC 보의 강섬유 보강효과를 평가하기 위한 것이다. 이를 위하여 13개의 실험체를 제작하여 성능실험을 실시하였다. 실험 변수는 전단경간비, 강섬유 혼입률, 전단보강근비이며 콘크리트 강도는 60 MPa이다. 기존 연구결과와 재료 및 부재 실험결과에 대한 분석에 의하면, 전단경간비 2.5와 강섬유 혼입률 1.0%인 경우가 강섬유 보강효과가 최대로 발휘되는 것으로 평가되었다. 강섬유 보강 및 전단경간비를 고려한 기존 전단내력식은 고강도 SFRC보의 내력을 과소평가하는 것으로 평가되었다. 향후 고강도 SFRC 보의 강도특성에 대한 보완 연구가 필요한 것으로 판단된다.

경간비와 헌치 기울기 변화에 따른 철근콘크리트 헌치보의 전단성능에 관한 연구 (Shear Capacity of Reinforced Concrete Haunched Beams by Shear Span-to-Depth Ratio and Haunch Slope)

  • 송호산
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.119-129
    • /
    • 2002
  • Reinforced concrete haunched beams have been used for enhancement of shear resistance of beams to avoid the stress concentration. But American and British codes do not give my formula for the design of haunched beams. The purpose of this research is to experimentally investigate the shear failure of reinforced concrete punched beams for various haunch inclinations and shear span-to-depth ratios. The experimental results showed that even though shear behavior of haunched beam were similar to that of resembled rectangular beams, shear span-to-depth ratios and inclinations of haunch had effects on shear cracking strength.

철근콘크리트 휨부재의 처짐 간접제어를 위한 한계 지간/깊이-비 연구 (Limit Span/Depth Ratio for Indirect Deflection Control in Reinforced Concrete Flexural Members)

  • 최승원;김우
    • 대한토목학회논문집
    • /
    • 제31권1A호
    • /
    • pp.35-41
    • /
    • 2011
  • 콘크리트구조설계기준에서는 일반적으로 처짐을 제어하기 위해 직접처짐제어법과 간접처짐제어법을 제시하고 있다. 이 때 처짐/깊이-비는 허용 처짐량을 초과하지 않도록 제한된다는 점에서 간접처짐제어법이 더 효과적이다. 실제 처짐량은 많은 요소에 의해 영향을 받기 때문에 실제 처짐량을 정확하게 산정하는 것은 어렵다. 이 연구에서는 철근콘크리트 부재의 사용한 계상태에서 처짐량을 직접 계산함으로써 한계 지간/깊이-비를 산정하였다. 이 때 처짐은 재료 모델로부터 산정된 휨곡률을 통해 산정하였다. 해석의 주요 변수는 인장증강효과 모델, 콘크리트 강도, 단면 크기 및 압축 철근의 유무이다. 해석 결과 2차식 형태의 인장증강효과 모델을 사용함으로써 해석의 일관성을 도모할 수 있는 것으로 나타났다. 또한 한계 지간/깊이-비는 단면 크기와 관계없이 재료 강도와 인장 및 압축 철근비에 따라 변화하는 것으로 나타났다.

Behavior of reinforced concrete corbels

  • Lu, Wen-Yao;Lin, Ing-Jaung
    • Structural Engineering and Mechanics
    • /
    • 제33권3호
    • /
    • pp.357-371
    • /
    • 2009
  • Test results of thirteen reinforced concrete corbels with shear span-to-depth ratio greater than unity are reported. The main variables studied were compressive strength of concrete, shear span-to-depth ratio and parameter of vertical stirrups. The test results indicate that the shear strengths of corbels increase with an increase in compressive strength of concrete and parameter of vertical stirrups. The shear strengths of corbels also increase with a decrease in shear span-to-depth ratio. The smaller the shear span-to-depth ratio of corbel, the larger the stiffness and the shear strength of corbel are. The higher the concrete strength of corbel, the higher the stiffness and the shear strength of corbel are. The larger the parameter of vertical stirrups, the larger the stiffness and the shear strength of corbel are. The softened strut-and-tie model for determining the shear strengths of reinforced concrete corbels is modified appropriately in this paper. The shear strengths predicted by the proposed model and the approach of ACI Code are compared with available test results. The comparison shows that the proposed model can predict more accurately the shear strengths of reinforced concrete corbels than the approach of ACI Code.

Shear strength prediction of PRC coupling beams with low span-to-depth ratio

  • Tian, Jianbo;Shen, Dandan;Li, Shen;Jian, Zheng;Liu, Yunhe;Ren, Wengeng
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.757-769
    • /
    • 2019
  • The seismic performance of a coupled shear wall system is governed by the shear resistances of its coupling beams. The plate-reinforced composite (PRC) coupling beam is a newly developed form of coupling beam that exhibits high deformation and energy dissipation capacities. In this study, the shear capacity of plate-reinforced composite coupling beams was investigated. The shear strengths of PRC coupling beams with low span-to-depth ratios were calculated using a softened strut-and-tie model. In addition, a shear mechanical model and calculating method were established in combination with a multi-strip model. Furthermore, a simplified formula was proposed to calculate the shear strengths of PRC coupling beams with low span-to-depth ratios. An analytical model was proposed based on the force mechanism of the composite coupling beam and was proven to exhibit adequate accuracy when compared with the available test results. The comparative results indicated that the new shear model exhibited more reasonable assessment accuracy and higher reliability. This method included a definite mechanical model and reasonably reflected the failure mechanisms of PRC coupling beams with low span-to-depth ratios not exceeding 2.5.

비부착 긴장재의 응력 변화에 영향을 미치는 변수에 관한 고찰 (Parametric study for influential factors on unbonded tendon stress increase)

  • 이선화;문정호;임재형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.651-656
    • /
    • 2000
  • The strain compatibility analysis shows that the influential parameters of loading type, reinforcing ratio, and span-depth ratio affect on the tendon stress in unbonded prestresses concrete member significantly. However, existing test results did not comply exactly with the analytical results. In consequence, the present study was planned to examine the parameters in order to complete Moon/Lim's design equation. The test variables with 12 specimens were loading type, reinforcing ratio, and span-depth ratio. As results, the effect of influential parameters were examined throughly and Moon/Lim's design equation was proven to be accurate.

  • PDF

포스트텐션된 3연속 스팬 슬래브의 실험연구 (Experimental Study on Post-tensioned 3-Continuous Span Slabs)

  • 임재형;문정호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.668-673
    • /
    • 1998
  • The specimen of current study has the same type with the 3-span slabs of Burns et al used in the study by Mojtahedi/Gamble, which laid a ground for the revision of the ACI318-77 code to the ACI 318-83 code. But those specimens was failed prematurely before it reached the ultimate strength which the specimen had. The reason is that bonded reinforcements were cut off where there is no need for the flexural reinforcement. As results. the slabs failed ultimately where the reinforcements was cut off. Thus, the tendon stresses of failure may have been much smaller than the values which culd reach if the bonded reinforcements were extended beyond the theoretical cut off points. On the based on the fact mentioned above. the specimens which had the same conditions as the specimens of Burns et al were used in the current study, but in which the reinforcements were distributed in a sequence for the reinforcements not to be cut anywhere in the 3-span. As a results, it was known that the current ACI code, revised by the result of Mojtahedi/Gamble's study, overestimated the effect of span/depth ratio on the members with high span/depth ratio. Thus it was concluded that the effect of span/depth ratio on the ultimate stress of unbonded tendon regulated by the current ACI code must be reconsidered and reevaluated.

  • PDF

전단-스팬비가 작은 고강도철근콘크리트 보의 전단성능 (Shear Capacity of Higth-Strength Concrete Beams With a Shear Span-Depth Ratio Between 1.5 and 2.5)

  • 문정일;안종문;김대근;이광수;이승훈;오정근;장일영;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.106-110
    • /
    • 1992
  • This paper is an experimental study on shear capacity of the high strength R/C beams with a shear span-depth ratio between 1.5 and 2.5. a total of 15 beams was tested to determine diagonal cracking and ultimate shear strength. The major variables are shear span-depth ratio (a/d=1.5, 2.0. 2.5) , vertical shear reinforcements ratio(Vs = 0 , 25, 50, 75, 100% ( Vs = Pv/Pv(ACI)), and concrete compressive strength (f'c= 747㎏/㎠). Test results indicate that ACI 318-89 Eq(11-31) generally underestimates shear strength carried by vertical shear reinforcements, and the mode of failure may change from shear tension to shear compression for the beams having higher Vs than 75%, thus the effectiveness of r-fy on ultimate shear strength (vu) decreased.

  • PDF

철근콘크리트 연속 깊은 보의 전단내력 평가에 대한 실험적 연구 (An Experimental Study on the Evaluation of Shear Strength in Reinforced Concrete Continuous Deep Beams)

  • 양근혁;정헌수;박정화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.393-396
    • /
    • 2004
  • The objective of this experimental study is to understand the shear behavior of reinforced concrete continuous deep beams. The main variables considered were concrete strength and shear span-to-depth ratio. Specimens of 4 two-span continuous deep beams were tested and compared with the strength of simple span beams. The results show that the influence of concrete strength on the shear strength of continuous deep beams is comparable to that on simple span deep beams. However, the effect of span-to-depth ratio is significantly greater than simple span deep beams.

  • PDF