• 제목/요약/키워드: span number

검색결과 549건 처리시간 0.03초

Desired earthquake rail irregularity considering random pier height and random span number

  • Jian Yu;Lizhong Jiang;Wangbao Zhou
    • Structural Engineering and Mechanics
    • /
    • 제90권1호
    • /
    • pp.41-49
    • /
    • 2024
  • In recent years, China's high-speed railway (HSR) line continues to expand into seismically active regions. Analyzing the features of earthquake rail irregularity is crucial in this situation. This study first established and experimentally validated a finite element (FE) model of bridge-track. The FE model was then combined with earthquake record database to generate the earthquake rail irregularity library. The sample library was used to construct a model of desired earthquake rail irregularity based on signal processing (SFT) and hypothesis principle. Finally, the effects of random pier height and random span number on desired irregularity were analyzed. Herein, an equivalent method of calculating earthquake rail irregularities for random structures was proposed. The results of this study show that the amplitude of desired irregularity is found to increase with increasing pier height. When calculating the desired irregularity of a structure with unequal pier heights, the structure can be regarded as that with equal pier heights (taking the largest pier height). For a structure with the span number large than 9, its desired irregularity can be considered equal to that of a 9-span structure. For the structures with both random pier heights and random span number, their desired irregularities are obtained by equivalent calculations for pier height and span number, respectively.

SMF 길이와 RDPS가 분포가 균일한 분산 제어 광전송 링크에서 광섬유 중계 구간 수에 따른 시스템 성능 (System Performance Depending on the Fiber Span Number in Dispersion Managed Optical Transmission Links with Uniform Distributions of SMF Lengths and Residual Dispersion Per Span)

  • 이성렬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.620-621
    • /
    • 2015
  • 그룹 속도 분산과 비선형 효과의 상호 작용에 의해 왜곡되는 WDM 신호의 보상을 위해 전체 전송로 중간에 광 위상 공액기 (optical phase conjugator)가 적용되고 중계 구간의 단일 모드 광섬유(SMF; single mode fiber) 길이와 RDPS(residual dispersion per span) 분포가 일정한 광전송 링크에서 전체 중계 구간 수에 따른 시스템 성능을 비교 분석하였다.

  • PDF

호남지방 전통주택에서의 규모와 평면형식 -전남 장흥군 관산읍 방촌만을을 중심으로- (Plan and Scale in the Traditional Houses of Honan Province - Based on the Case of Bangchon Village in Janghung County -)

  • 김성우;이소연
    • 건축역사연구
    • /
    • 제2권2호
    • /
    • pp.66-76
    • /
    • 1993
  • The plan of Korean traditional houses are devided by the span-units which is the automatic result of the timber construction. This study aims to analyze the ways plan type change when the number of span changes. One village named Bangchon in Honan Province was selected where we investigated more than 30 houses ranging from 3 span to 6 span. It is identified that there were certain rules which govern the plan change when number of span change. When one span is added onto 3 span houses, wooden floor of one span is added in between the two ondol-rooms. When one span is added onto 4 span houses, kitchen is enlarged. When one span is added onto 5 span houses, wooden floor is enlarged into 2 span, Also the plan of Man's quarter(Sarang-chae) was investigated and compared to Lady's quarter. The research proves that such rules of plan change need to be considered as a basic standard of analysis when traditional houses are to be studied.

  • PDF

서울대학교병원의 방사선치료장비 운용 통계에 관한 고찰 (A Statistical Review on States Relating to Operation of Radiotherapy Equipments in Seoul National University Hospital)

  • 박흥득;김완선;안희용
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.21-30
    • /
    • 1994
  • To analyze the states of operation of radiotherapy facilities in the period from 1979 to 1992 and to get the base for efficient operation and maintenance of the radiotherapy facilities. Data on the records of annual number of patients operated by each facility; span of suspension of operation, the cost and span of repairing, and parts of oui-of-order in the period from 1979 to 1992 were analyzed. We made a comparative analysis of average annual number of patients, annual span of the suspension of operation, annual cost ratio of repair, span of repairing per break down, and total number of broken parts. We could get following annual number of patients(day), span of the suspension of span ($\%$)(day). annual cost ratio fo repair($\%$), span of repairing per break down(Min-Max, day), and number of broken parts from this analysis. 1. Cobalt unit (Picker C-9) : 10,389(43), 0.4(0.83) 0.07, 1hr-2, 3 2. Linac(Clinac 6/100) : 11,492(50), 4.0(9.57), 0.98, 1hr-30, 12 3. Linac(Clinac 18) : 9.115(44), 12.7(30.5), 3.54, 1hr-108. 41 4. Simulator(Picker Ther-X) : 2,017(9), 0.51(1.3), 0.24, 1hr-2, 7 5. RTP(Capentec Cap-plan) : 528(2), 0.4(0.93), - hrs, - The conclusion obtained from statistical analysis above are as follows. 1. The rate of operation of Cobalt unit($99.6\%$) was higher that of Linear Accelerators ($87.3\%$). The rates operation of Simulator and RTP computer were very close to that of Cobalt unit. 2. In order to raise up the working ratio of accelerator. it is desirable that we keep our engineer to learn a sufficient technical skill and the equipment agent to stock sufficient spare parts. 3. In order to maintain Linear Accelerator efficiently, it is desirable to have annually $2.3\%$ of the purchase price of equiment for repairing.

  • PDF

박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사 (A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation)

  • 여경환;유인호;이한철;정재완;최경이
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

인벌류트 곡선의 Biarc Curve Fitting 최적화에 관한 연구 (A Study on the Optimized Biarc Curve Fitting of Involute Curve)

  • 조승래;이춘만
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.71-78
    • /
    • 1999
  • The determination of the optimum biarc curve passing through a given set of points along involute curve is studied. The method adopted is that of finding the optimum number of span and the optimum length of the span such that error between the biarc curve and involute curve minimum. Iterative method is effectively used to find the optimim number and length of the span on involute curve with reduced length of NC-code.

  • PDF

Modifications to fire resistance ratings of steel frames based on structural configuration: A probabilistic-based approach

  • Behnam, Behrouz
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.661-672
    • /
    • 2021
  • In this article, the role of spans number and length in fire-resistance ratings (FRRs) of fireproofed steel frames are investigated. First, over a span-lengthening scenario, two one- and three-bay frames under the ISO834 fire are examined. It is shown that the FRRs of the frames rely highly on the changes made on their span length. Second, a building designed for three spans number of three, four, and five under natural fire is investigated. The beams are designed for two load-capacity-ratios (LCRs) of optimum and ultimate. The fire curves are determined through a probabilistic-based approach. It is shown that the structural vulnerability vastly increases while the number of spans decreases. The results show that for an optimum LCR, while the five-span frame can meet the required FRR in 87% of the fire scenarios, the four- and three-span frames can meet the required FRR in only 56%, and 50% of the fire scenarios, respectively. For an ultimate LCR, the five-, four- and three-span frames can meet the required FRR in 81%, 50%, and 37.5% of the fire scenarios, respectively. Functional solutions are then proposed to resolve the insufficiencies in the results and to rectify the application of the standard-based FRRs in the cases studied. The study here highlights how employing current standard-based FRRs can endanger structural safety if they are not connected to structural characteristics; a crucial hint specifically for the structural engineering community who may be not well familiar with the fundamentals of performance-based approaches.

PSC 바닥판의 정적거동특성에 관한 연구 (A Study on the Static Behavior of PSC Bridge Decks)

  • 주봉철;김영진;이정우;김병석;박성용;이필구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.519-524
    • /
    • 2002
  • The long span PSC deck of composite girder bridge should be needed in order to improve the endurance and to simplify the structure of the steel bridge. However, there have been few domestic research activities about long-span PSC decks for the steel bridges with a small number of girders. In this study, a literature survey is performed to develop a new deck system for the steel bridge with a small number of girders. By considering the characteristics of a small number of girders bridge system, a cast-in-place long span PSC deck is proposed for a small number of girders bridges. To examine structural behavior and safety of the proposed PSC deck, the real scale partial models of the deck(12m$\times$3.2m) are tested under the static loading. In the test, the failure mode and behavior of each specimen, and ultimate load carrying capacity of the proposed PSC deck are identified.

  • PDF

80 km × 56 spans의 초장거리 전송 링크에서 왜곡된 WDM 채널의 보상 (Compensation of the Distorted WDM Channels in Ultra-long Transmission Link of 80 km × 56 Spans)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제23권3호
    • /
    • pp.251-257
    • /
    • 2019
  • 분산 제어와 광 위상 공액이 결합된 초장거리 광전송 링크의 구조를 제안하였다. 전체 전송 링크는 80 km (단일 모드 광섬유 span) ${\times}$ 56 fiber span으로 구성된다. 왜곡된 파장 분할 다중 채널을 보상하기 위하여 각 fiber span의 단일 모드 광섬유 길이와 중계 구간 당 잉여 분산을 점진적으로 증가/감소시키는 인위적 분포 구조를 채택하였다. 다른 선행 연구에서 제안된 인위적 분포는 fiber span이 많아질수록 보상 효과가 줄어들 수 있기 때문에 인위적 분포 패턴을 9개의 fiber span 마다 반복시키는 구조를 분산 제어와 광 위상 공액 링크에 적용하였다. 시뮬레이션 결과 제안된 4개의 분포 패턴 중 특정한 인위적 분포 패턴이 적용된 링크를 사용하면 기존에 제안되었던 반복이 없는 인위적 분포에 비해 왜곡된 WDM 채널의 보상 효과가 다소 크게 나타나는 것을 확인하였다.

파이프 골조 온실의 구조 실태 및 안전성 검토(농업시설) (Field Survey and Structural Safety Analysis of Pipe Framed Greenhouses)

  • 남상운;김문기;유인호
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.315-320
    • /
    • 2000
  • An investigation and structural safety analysis was conducted to get the basic data for establishing maintenance strategy of pipe framed greenhouses. The number of greenhouses investigated was 108 in total. Most multi-span greenhouses had narrower width and lower height than the standard 1-2W greenhouse, and most of single-span greenhouses were tunnel type. In multi-span greenhouses, the size and interval of frameworks such as rafter, purline, column, and cross beam were mostly suitable, but frameworks of single-span greenhouses were mostly insufficient.

  • PDF