콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구 (A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities)

  • 지태정;곽병준;민병인
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

Radiation Effects on the Power MOSFET for Space Applications

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.449-452
    • /
    • 2005
  • The electrical characteristics of solid state devices such as the bipolar junction transistor (BJT), metal-oxide semiconductor field-effect transistor (MOSFET), and other active devices are altered by impinging photon radiation and temperature in the space environment. In this paper, the threshold voltage, the breakdown voltage, and the on-resistance for two kinds of MOSFETs (200 V and 100 V of $V_{DSS}$) are tested for ${\gamma}-irradiation$ and compared with the electrical specifications under the pre- and post-irradiation low dose rates of 4.97 and 9.55 rad/s as well as at a maximum total dose of 30 krad. In our experiment, the ${\gamma}-radiation$ facility using a low dose, available at Korea Atomic Energy Research Institute (KAERI), has been applied on two commercially available International Rectifier (IR) products, IRFP250 and IRF540.

  • PDF

The Effects of ${\gamma}-rays$ on Power Devices

  • Lho, Young-Hwan;Kim, Ki-Yup;Cho, Kyoung-Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2287-2290
    • /
    • 2003
  • The electrical characteristics of power devices such as BJT (Bipolar Junction Transistor), and MOSFET (Metal Oxide Field Effect Transistor), etc, are altered due to impinging photon radiation and temperature in the nuclear or the space environment. In this paper, BJT and MOSFET are the two devices subjected to ${\gamma}$ radiation. In the case of BJT, the current gain (${\beta}$) and the collector to Emiter breakdown voltage ($V_{CEO}$) are the two main parameters considered. When it was subjected to ${\gamma}$ rays, the ${\beta}$ decreases as the dose level increases, whereas, $V_{CEO}$ gradually increases as the dose level increases. In the case of MOSFET, the threshold voltage is decreasing as the dose level increases. Here it has been observed the decent rate is an increasing function of the threshold voltage. The on-resistance does not change with respect to the dose. Both the devices recover back the original specification after the annealing is finished. No permanent damage has been occurred.

  • PDF

우리별 1호에서의 총 방사선 측정 실험 (RESULTS OF THE TOTAL DOSE EXPERIMENT ON KITSAT-1)

  • 이대희;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.80-86
    • /
    • 1997
  • 지구 주변의 방사선대에 존재하는 고에너지 입자들은 위성계의 전자 재료, 부품, 및 집적 회로 등에 일시적 또는 장기적인 영향을 준다. 따라서 이러한 고에너지 입자들에 의한 우주 방사선 환경에 대한 정보를 아는 것은 매우 중요하다. 총 방사선의 양을 측정하는 장치로서 MOSFET을 개량한 RADFET을 많이 사용하는데, 본 연구에서는 $Co^{60}{\gamma}-ray$를 이용하여 TOT500 RADFET을 보정하였다. 그 결과, 방사선에 대한 RADFET의 특성 곡선 변화가 온도의 변화에 매우 민감한 것을 확인하였다. 또한, 우리별 1호에서의 TDERUF과를 위성의 온도와 비교하였으며, 그 결과 TDE 실험에 나타난 특이한 형상은 지구에 의한 위성의 식 현상에서 비롯된 온도 변화가 주된 원인이었음을 확인하였다.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발 (Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor)

  • 천종규;김성환
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.367-373
    • /
    • 2023
  • 비행시 승무원이나 승객은 우주방사선과 공기나 비행기 기체와 반응하여 발생한 2차 산란선 등에 의해 피폭을 받게 된다. 항공기 승무원의 경우 우주기상 환경 시뮬레이션을 이용하여 계산된 피폭선량으로 방사선 안전관리를 적용받고 있다. 하지만, 태양활동이나 고도, 비행경로 등에 따라 피폭선량이 가변적이어서 계산법보다는 항로별 측정하는 것이 권고되고 있다. 본 연구에서는 범용 Si 센서와 다중채널파고분석기를 이용하여 우주방사선 선량을 측정할 수 있는 선량계를 개발하였다. 선량계산은 미우주항공국의 우주방사선 측정장비인 CRaTER(Cosmic Ray Telescope for the Effects of Radiation)의 알고리즘을 적용하였다. 표준교정시설에서 Cs-137 662 keV 감마선으로 에너지 및 선량교정을 시행하였으며, 실험 범위에서 선량률 의존성이 없음을 확인하였다. 제작된 선량계를 이용하여 2023년 5월 두바이 인천 구간의 국제선에서 직접 선량을 측정한 결과 국내 우주방사선 선량평가코드(KREAM; Korean Radiation Exposure Assessment Model for Aviation Route Dose)로 계산된 결과와 12% 이내로 비슷하게 나타났으며, 고도와 위도가 높아짐에 따라 계산 결과와 동일하게 선량이 증가하는 것을 확인하였다. 좀 더 많은 실증적 검증 실험이 요구되는 제한점은 있지만, 항공기 내 또는 개인 피폭선량 모니터링에 가성비가 우수한 선량계로 충분한 활용 가능성을 확인하였다.

핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰 (A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department)

  • 유재숙;장정찬;김호성
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.50-56
    • /
    • 2012
  • 일시 출입자로 분류된 핵의학과 출입 환경미화원은 주기적으로 타과와 업무순환을 하고, 또한 작업 시간과 환경 등의 변화가 많기 때문에 관리하기에 어려운 점이 있으며 따라서 이들의 분류를 명확히 할 필요가 있다. 이에 본 논문에서는 핵의학과에서 근무하는 환경미화원의 피폭 상황을 분석하여 일시 출입자로 분류된 조건의 타당성에 대하여 검토해 보고 작업 환경의 변화 및 근무 시간의 조절이 필요한가를 알아보았다. 우선 먼저 PET실과 혈액 검사실에서 근무하는 환경미화원과 감마 카메라실에서 근무하는 환경 미화원 2명을 대상으로 한 달간 근무 시간 중에 OSL을 각각 착용시켜 개인 피폭 선량을 측정하였다. 둘째로 survey meter를 이용하여 두 명의 환경미화원의 작업 환경, 근무 형태에 따라 시간대 별로 핵의학과 내 14개 구역을 선정, 총 10회 공간 선량률을 측정한 결과 이들의 피폭 선량은 연간 1mSv를 초과하지 않았으며, survey meter를 이용하여 조사한 결과 또한 연간 1 mSv를 초과하지 않을 것으로 추정되지만 그 수치가 1 mSv에 근접하였다. 따라서 일시 출입자로써의 분류를 좀 더 명확히 하기 위해서는 PET 안정실과 같은 피폭이 상대적으로 많은 구역에서의 노출 확률을 줄이기 위하여 이들에게 방사선 관리 구역내 교육을 실시하고, 또한 근무시간 및 근무 형태를 적절히 변경한다면 이들의 피폭 선량은 확연히 줄어들 것으로 사료된다.

  • PDF

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

방사성동위원소 사용시설(내/외) 화장실의 외부선량률 (Dose Rate of Restroom in Facilities using Radioisotope)

  • 조용귀;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.237-246
    • /
    • 2016
  • 방사성동위원소 사용시설 내/외 화장실 표면 방사선량률과 공간 방사선량률을 측정하여 화장실을 이용하는 환자 이외 방사선작업종사자 및 환자보호자 등의 안전성을 확보하고 방사선 방어 연구에 대한 기초 자료로 제시 하고자 한다. 2014년 5월 1일부터 7월 31일까지 인천광역시 소재 종합병원 방사성동위원소 사용시설 내/외 화장실 4곳의 공간 방사선량률과 작업 전/후 표면 방사선량률을 각각 측정하였다. 의료기관별 방사성동위원소 사용시설 내 화장실 이용 실태조사 결과 환자뿐만 아니라 환자 보호자, 일부 방사선 작업종사자까지 다양하게 이용하고 있었다. 화장실 내 공간 방사선량률 측정 결과 핵의학적 검사 중 감마촬영실을 이용하는 화장실의 누적 공간선량률은 8.86 mSv/hr으로 가장 높게 측정되었고, 방사성옥소 치료실 화장실은 7.31 mSv/hr, PET촬영실 화장실 2.29 mSv/hr, 외래 진료과 화장실 0.26 mSv/hr으로 각각 측정되었다. 방사성동위원소 작업 전/후 화장실 내 표면 방사선량률을 측정한 결과 대부분 환자 배설물이 직접 닫는 변기 앞에서 표면 방사선량률이 가장 높게 측정되었고, 화장실 내 중앙, 입구 순으로 측정되었다. 개봉선원은 물리적 반감기가 짧고 에너지가 낮아 비교적 안전하여 방사선 관리구역에서 안전하게 사용되고 있다. 그러나 저에너지 이며 짧은 반감기의 방사선원이라 하더라도 환자에게 투여되면 그 이후 환자는 움직이는 방사선원이 되며 환자가 이용하는 장소는 배설물에 의한 방사선 오염 장소가 된다. 따라서 효과적으로 유효선량을 최소화하고 불필요한 피폭선량을 줄이기 위해 방사성동위원소 투여 후 충분한 수분 섭취를 독려하여 생물학적 반감기를 낮추고, 물리적 반감기가 허용 선량이하로 될 때까지 주변인은 환자로부터 가급적 멀리 떨어져 생활하도록 권고되어야 한다.

고선량률 근접치료계획의 정도보증 프로그램 (Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans)

  • 한영이;추성실;허승재;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권3호
    • /
    • pp.238-244
    • /
    • 2003
  • 목적: 개별화되어 가는 고선량률 근접치료계획의 추세에 따라, 고성량률 근접치료계획의 절대적 선량과 상대적인 선량분포를 독립적으로 계산하여 환자의 해부영상 위에 겹쳐 표시할 수 있는 품질보증용 컴퓨터 프로그램을 개발한다. 대상 및 방법: 컴퓨터 프로그램은 먼저, 환자의 치료계획에서 계산된 선원의 위치, 각 위치에서의 조사시간, reference point에서의 선량, 치료계획이 실시된 날짜 등의 자료 입력을 필요로 한다. ICWG 권고 수식과 선원의 비등방성 표를 이용하여 $10\times12\times10\;(Cm^3)$의 공간에서 선량분포가 계산된 후 reference point에서의 선량이 자동적으로 치료계획의 결과와 비교된다. 모의치료의 영상이나 자기공명(Magnetic Resonance) 영상을 입력하고 사용자가 선택한 점을 수직으로 교차하는 3개의 평면에서 등선량곡선을 겹쳐서 보여준다. Gamma Med사의 Gam-madot (MDS Nordion, Germany)에서 표준 치료계획을 실행하여 정확성을 확인하였으며, Plato (Nucletron Cor-poration, The Netherlands)에서 실행된 9명의 환자치료계획과 비교하였다. 결과: 3개의 표준 치료계획에서 절대선량은 $2.8\%$ 내에서 일치하였으며 등 선량분포도 좋은 일치를 보였다. 9명의 환자에 대하여 시행된 치료계획과의 비교에서는 평균 $3.4\%$의 오차를 보였다. 결론: 개발된 컴퓨터 프로그램은 정확하고 신속하게 고선량률 치료환자의 치료계획의 정확성을 확인할 수 있게 해주며, 등선량 곡선을 환자의 해부적 영상에 결합할 수 있는 기능은 치료계획의 질을 높이는데 기여할 수 있을 것으로 기대된다.$39\%$), 복회음부 절제수술시 32건($97\%$), 측연의 경우 32건($97\%$), 후연의 경우 32건($97\%$), 그리고 전연의 경우 16건($45\%$)에서 부합되는 것으로 나타났다. 결론: 직장암의 수술 후 방사선치료 시 적절한 방사선치료 조사영역의 결정을 위하여 표준적인 조사영역을 제시 하였으나 개별 환자의 병변 위치와 진행상태, 수술 소견 등에 따라 적절한 변형은 필수적이라 하겠다. 이 권고안의 임상적 타당성은 향후 시행될 Patterns of Care 연구를 통하여 증명하는 것이 필요하겠다.정가능하고, 폐에 조사되는 방사선 양도 줄일 수 있었다.저부까지 거리 차이는 종양 크기가 4 cm 미만인 경우는 5.3 mm였으나 4 cm 이상일 때는 19.4 mm로 현저한 변화를 보였다. 자궁경관 굴곡각은 60세 미만인 경우 60세 이상보다 8$^{\circ}$ 정도 더 변화가 있었고, 종양 크기가 4 cm 이상일 때 미만일 때보다 2배 이상 굴곡 변화가 있었다. 결론: 자궁경부암 환자에서 근치적 방사선치료 시 치료에 따른 자궁 크기 및 위치 변화가 다양하고 개별적으로 예측하기 쉽지 않으므로, 특히, 60세 미만이거나 종양 크기가 4 cm 이상인 경우, 삼차원입체조형치료나 강도변조 방사선치료를 이용한 근치적 방사선치료 시 치료 중 개별환자의 계획용표적체적의 변화를 반드시 고려해야 한다고 생각한다.량체적히스토그램, Lymankutcher 모델에 의한 정상조직합병증발생률 및 기타 선량통계값 등 모든 면에 있어서 우월성을 확인할 수 있었다. 향후 이러한 결과가 임상에서 실질적인 합병증 발생률 감소와 잘 연계되는지 계속적인 추적관찰 및