• Title/Summary/Keyword: source zone

Search Result 545, Processing Time 0.041 seconds

Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation (수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구)

  • Nam, Yu-Jin;Oh, Jin-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

Static Stability Analysis Using Voltage Source Converter HVDC (전압형 컨버터 HVDC를 이용한 정적 안정도 해석)

  • Chae, Byung-Ha;Oh, Sae-Shung;Jang, Gil-Soo;Lee, Byung-Jun;Han, Byung-Mun;Cha, Jun-Min;Kim, Chan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.66-68
    • /
    • 2004
  • The current source HVDC using thyristor valves requires the reactive power compensator, the increasement of short circuit ratio(SCR) by AC source, and the harmonic filter in power transmission. The voltage source HVDC that controls active power and reactive power independently can minimize the requirements and also can be used as a reactive power source without additional reactive power compensators. In this paper, the solution of supplying active power using direct current transmission and compensating additional reactive power at the heavy load zone in metropolitan area is proposed and verified by simulations.

  • PDF

A study on an efficient prediction of welding deformation for T-joint laser welding of sandwich panel PART I : Proposal of a heat source model

  • Kim, Jae Woong;Jang, Beom Seon;Kim, Yong Tai;Chun, Kwang San
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.3
    • /
    • pp.348-363
    • /
    • 2013
  • The use of I-Core sandwich panel has increased in cruise ship deck structure since it can provide similar bending strength with conventional stiffened plate while keeping lighter weight and lower web height. However, due to its thin plate thickness, i.e. about 4~6 mm at most, it is assembled by high power $CO_2$ laser welding to minimize the welding deformation. This research proposes a volumetric heat source model for T-joint of the I-Core sandwich panel and a method to use shell element model for a thermal elasto-plastic analysis to predict welding deformation. This paper, Part I, focuses on the heat source model. A circular cone type heat source model is newly suggested in heat transfer analysis to realize similar melting zone with that observed in experiment. An additional suggestion is made to consider negative defocus, which is commonly applied in T-joint laser welding since it can provide deeper penetration than zero defocus. The proposed heat source is also verified through 3D thermal elasto-plastic analysis to compare welding deformation with experimental results. A parametric study for different welding speeds, defocus values, and welding powers is performed to investigate the effect on the melting zone and welding deformation. In Part II, focuses on the proposed method to employ shell element model to predict welding deformation in thermal elasto-plastic analysis instead of solid element model.

A Study on the Radiating Source of Electro-magnetic Waves in the Cabin of Automobile (자동차 실내의 전자파 복사원에 관한 연구)

  • Choe, Gwang-Je
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.107-114
    • /
    • 2006
  • This paper investigates the radiating source of electro-magnetic waves in the cabin of automobile with spark ignition engine. Front seats are very close to the engine room where electro-magnetic waves are expected to be radiating. But front seat area is believed to be a blind zone, which is not affected by radiating electro-magnetic waves, because a bulk board and floor board shield the front seat area. The level and frequency spectrum of electro-magnetic waves are measured at the passenger seat and the engine room. The measured frequency range is $145{\sim}365MHz$. As a results, the level of the electro-magnetic waves of automatic transmission vehicle is greater than -82dBm. The shapes of frequency spectrum of both engine room and passenger seat are look alike. But the level of electro-magnetic waves of manual transmission vehicle is less than -82dBm and the shapes of frequency spectrum of engine room and passenger seat are different to each other. From these results, we can say that any mal-function caused by electro-magnetic waves in the automobile cabin are only possible for automatic transmission vehicle. Also, it is believed that the radiating source of electro-magnetic waves is inside the vehicle. Thus, based on the transmission line theory, this paper presumably concludes that the cables which connect all the components inside a automatic transmission vehicle must be a radiating source of electro-magnetic waves in the cabin.

Propagation characteristics of blast-induced vibration to fractured zone (파쇄영역에 따른 발파진동 전파특성)

  • Ahn, Jae-Kwang;Park, Duhee;Park, Ki-Chun;Yoon, Ji Nam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.959-972
    • /
    • 2017
  • In evaluation of blast-induced vibration, peak particle velocity (PPV) is generally calculated by using attenuation relation curve. Calculated velocity is compared with the value in legal requirements or the standards to determine the stability. Attenuation relation curve varies depending on frequency of test blasting, geological structure of the site and blasting condition, so it is difficult to predict accurately using such an equation. Since PPV is response value from the ground, direct evaluation of the structure is impractical. Because of such a limit, engineers tend to use the commercial numerical analysis program in evaluating the stability of the structure more accurately. However, when simulate the explosion process using existing numerical analysis program, it's never easy to accurately simulate the complex conditions (fracture, crushing, cracks and plastic deformation) around blasting hole. For simulating such a process, the range for modelling will be limited due to the maximum node count and it requires extended calculation time as well. Thus, this study is intended to simulate the elastic energy after fractured zone only, instead of simulating the complex conditions of the rock that results from the blast, and the analysis of response characteristics of the velocity depending on shape and size of the fractured zone was conducted. As a result, difference in velocity and attenuation character were calculated depending on fractured zone around the blast source appeared. Propagation of vibration tended to spread spherically as it is distanced farther from the blast source.

Float Zone Growth of Superconduction $Bi_2Sr_2CaCu_2O_8$ Fiber with Halogen Lamp (할로겐 램프 열원을 이용한 초전도성 $Bi_2Sr_2CaCu_2O_8$ Fiber의 Float Zone 성장)

  • 김철진;정준기
    • Korean Journal of Crystallography
    • /
    • v.7 no.2
    • /
    • pp.147-155
    • /
    • 1996
  • Floating Zone Image furnace with halogen lamps as heat source has been made and applied to the growth of high-Tc superconductor Bi2Sr2CaCu2O8. The manufactured crystal growth equipment is composed of holder unit for setting the halogen lamps at the focal point of the elliptical mirror, image furnace with maximum temperature of 1800℃ with 1kW halogen lamps, cooling unit, feeding unit for supplying source material to the molten zone, pulling unit for crystal growth, and the control unit in the range of 2mm/hr -40 mm/hr vertical movement and 15rpm - 12rpm rotation. Bi2Sr2CaCu2O8 fibers have been grown with 300W halogen lamps and characterized with XRD, SEM and EDS. The growth condition was air atmosphere, growth speed 3∼4mm/hr, rotation speed of upper and lower part 20∼25 rpm. The fiber was composed of 20∼25 rpm matrix phase and secondary phases such as (Sr,Ca)CuO2 and (Sr,Ca)2CuO3.

  • PDF

Carbohydrate Concentration and Composition in Source and Sink Tissues of Two Tall Fescue Genotypes

  • Song, Beom-Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.4
    • /
    • pp.273-278
    • /
    • 1998
  • Carbohydrate metabolism and partitioning are dependent on relationships between sources and sinks which can be affected by rates of photosynthesis and respiration. Fructan, the major form of stored carbohydrate in tall fescue (festuca arundineacea Schreb.), changes in concentration during growth and in response to the environment. Objectives of this study were i) to examine the content and the composition of carbohydrates in five tissues (mature leaf blade, immature leaf blade, leaf elongation zone, terminal meristem, and root tips) of two tall fescue genotypes, one with high yield per tiller (HYT) and one with low yield per tiller (LYT), and ii) to compare the reserved and utilized carbohydrates among above five different tissues, particularly between the leaf elongation zone and root tips. The established vegetative tillers of the HYT and LYT genotypes were grown in a controlled-environment growth chamber. Water-soluble carbohydrate (WSC) in the leaf elongation zone was about 22% of dry weight in the HYT and about 19% in the LYT genotype. The root tip also had high WSC, about 12% of dry weight in the HYT and 6% in the LYT genotype. Hexoses and sucrose were the major components of total WSC in all tissues except the leaf elongation zone. The growing tissues (sinks), i.e., the leaf elongation zone and root tip, had a high proportion of low degree of polymerization fructan, i.e., 3 to 8 hexose units.

  • PDF

Characteristics for Effects of Co2 Addition to Oxygen-Enriched Combustion (산소부화연소에서 Co2 첨가에 대한 연소 특성)

  • Kim, Han-Seok;Kim, Ho-Keun;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • $CO_2$ is a well-known green house gas as well as the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. Because its adiabatic flame temperature is relatively too high, existing facilities must be changed or the flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were investigated experimentally for the various oxygen-enriched ratios(OER) by the addition of $CO_2$, under constant $O_2$ flow rate. Results showed that the reaction zone was quenched and broadened as the addition of $CO_2$ was increased. The emission of NOx in flue gas was decreased as decreasing temperature in reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone was increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0%, but the composition of CO was decreased by quenching effect at OER=50% and 100%.

Effects of $CO_2$ addition to Oxygen-Enriched Combustion (산소부화연소에서 $CO_2$ 첨가에 대한 영향)

  • Kim, Ho-Keun;Kim, Han-Seok;Ahn, Kook-Young;Kim, Yong-Mo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1389-1394
    • /
    • 2003
  • $CO_2$ is a well-known green house gas, which is the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. But the adiabatic flame temperature is too high. So existing facilities must be changed, or the adiabatic flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were studied experimentally for the various oxygen-enriched mtios(OER) by addition of $CO_2$ under coustant $O_2$ flowrate. Results showed that the reaction zone was quenched, broadened, as addition of $CO_2$ was increased. Temperature has a large effect on the NOx emission. The emission of NOx in flue gas decreased due to the decreased temperature of reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0, but the composition of CO decreased by quenching effect at OER=50 and 100%.

  • PDF

DZDC Coefficient Distributions for P-Frames in H.264/AVC

  • Wu, Wei;Song, Bin
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.814-817
    • /
    • 2011
  • In this letter, the distributions of direct current (DC) coefficients for P-frames in H.264/AVC are analyzed, and the distortion model of the Gaussian source under the quantization of the dead-zone plus-uniform threshold quantization with uniform reconstruction quantizer is derived. Experimental results show that the DC coefficients of P-frames are best approximated by the Laplacian distribution and the Gaussian distribution at small quantization step sizes and at large quantization step sizes, respectively.