• 제목/요약/키워드: source water

검색결과 4,418건 처리시간 0.033초

동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석 (Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation)

  • 양철호;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

철도교량 설계 지반조사를 위한 고분해능 수면 탄성파반사법의 응용 사례 (High Resolution Hydroacoustic Investigation in Shallow Water for the Engineering Design of Railroad Bridge)

  • 김중열;;김유성;김기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.231-238
    • /
    • 2001
  • To investigate the underground structure of shallow water, Han-river near Yangsou-Ri, high resolution hydroacoustic measurements were carried out for the engineering design of railroad bridge. The acoustic source was a Boomer with an energy of 90 to 280J and in a frequency range up to about 16KHz. The reflected signals were received by using both traditional hydrophones(passive element) and a specially devised receiver unit(active element) mainly composed of piezofilms and preamplifier. They are connected to the "SUMMIT" data acquisition system(DMT-GeoTec company), where the sampling interval was set to 1/32㎳. The source position was continuously monitored by a precision DGPS system whose positioning accuracy was on the order of loom. For the quality control purposes, two different source-receiver geometries were taken. That is to say, the measurements were repeated along the profile everytime depending on the different source energy(175J, 280J), the receiving elements(passive, active) and two different source-receiver geometries. It was shown that the data resolution derived from a proper arrangement with the active hydrophone could be greatly enhanced and hence the corresponding profile section caused by the regular data processing system "FOCUS" accounted excellently for the underground formation below the shallow water.w the shallow water.

  • PDF

산림 활엽수 지역의 강우유출수 유출특성 및 EMC 산정 (Determination of EMC and Washoff Characteristics of Stormwater Runoff from Broad-Leaved Forest Areas)

  • 강창국;이소영;조안;이재운;김이형
    • 환경영향평가
    • /
    • 제18권6호
    • /
    • pp.393-399
    • /
    • 2009
  • The water of rivers and lakes are affecting by point and nonpoint source pollutions. The point source pollution can be controlled by establishing the treatment plants. However, nonpoint source pollution by various human activities is not easy to be controlled because it is difficult to determine the exits of the water flow and have many exit points. Due to contribution of nonpoint source pollution, the achievement ratio of water quality in rivers and lakes is not high. TMDL is the outstanding water quality control policy because all of the pollutant loadings from the watershed area are counting on the input loads. Our aqua-ecosystem has self-purification process by biological, physical and ecological processes. The self-purification process can remove the pollutant load from background concentrations. Usually forest area is main source of background concentrations. In Korea, about 70% of the national boundary area consists of mountains. This study is conducting as part of long-term monitoring to determine the Event Mean Concentration during a storm. The monitoring was performed on a broad-leaved tree area.

충주댐 유역의 오염원에 따른 오염부하량 발생 특성 (Characteristics of Pollutant Loads according to Types of Sources for the Chungju Dam Watershed)

  • 김철겸;김남원
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.465-472
    • /
    • 2008
  • Soil and Water Assessment Tool (SWAT) model was selected as a tool for assessing the effect of pollutant sources on the total loads from the Chungju Dam upstream watershed. The model was constructed through calibration of parameters related to nitrogen (N) and phosphorus (P), which was based on the runoff and sediment modeling performed in the previous research. Using this, the spatial and temporal pollutant loadings by source type were investigated. Results of this study indicated that in most forested upstream sub-watersheds, pollutant loadings from point sources were very low, and total loadings by point and non-point sources were also insignificant. On the other hand, in #14 sub-watershed including Jecheon city, the loadings by point source were relatively considerable. For the whole watershed, non-point sources accounted for 99% of sediment, 97% of N, and 93% of P loads. And monthly non-point source loadings were concentrated on rainy summer season, while point source loadings of N and P kept nearly constant throughout the year and were high on dry winter season relative to non-point source.

Study on Energy Saving Properties by using City- Water as a Heat Source for Dwellings

  • Chung, Yong-Hyun;Mizuno, Minoro;Simoda, Yoshiyuki;Kum, Jong-Soo;Choi, Kwang-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.168-176
    • /
    • 1998
  • A simulation study was conducted to use city-water which is thermally regulated by unused energy as a heat source for urban dwellings. This study utilized multiple heat pump system using the city-water as a heat source and suggested a method of reducing the heat load of hot water supply. The simulation was done to calculate the energy savings at a dwelling for a year. The relation between the controlled temperature of city-water. and electric energy in all seasons was also investigated. Furthermore, it has been found that the controlled water system can lead to considerable energy savings and decrease environmental load such as sensible waste heat which otherwise would form heat islands.

  • PDF

Application of Water Quality Management System of Freshwater Lake

  • Kim, Sun-Joo;Kim, Phil-Shik;Lee, Joo-Young
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.38-48
    • /
    • 2003
  • Lake water quality assessment information is useful to anyone involved in lake management, from lake owners to lake associations. It provides lake water quality criteria, which can improve the ways how to manage out lake resources and how to measure current conditions. It also provides a knowledge base so that the lakes can be protected and restored. Here, the Freshwater Lake Water Quality Management System(FLAQUM) was developed. The results of FLAQUM application by scenario proved that pollutant load at rainfall by the nonpoint sources was much more than normal times at rainfall. From the result of Scenario I (pollutant source increase case), the concentrations of Boryeong freshwater lake were BOD 9.43mg/L, T-N 4.53 mg/L and T-P 0.21 mg/L, respectively, and those values exceed the standard of agricultural water. And in case of Scenario I and II(the present case) excluding Scenario III (pollutant source decrease case), all of T-N and T-P are either mesotrophication or eutrophication, on the other hand when 60% of pollution source is removed, the concentrations of Scenario III were BOD 3.21 mg/L, T-N 0.95 mg/L, T-P 0.11 mg/L, respectively, and which satisfies the standard of agricultural water quality.

논 비점오염 저감을 위한 담수위 관리와 배출수 여과의 효과 분석 (Management of Ponding Depth and Discharge Filtration from Paddy Fields for Controlling Non-point Source Pollution)

  • 최용훈;김영진;김승희;김민영
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.125-130
    • /
    • 2015
  • Field study was carried out to assess the effect of automatic inlet and filtration outlet to reduce non-point source discharge and save agricultural irrigation water from paddy. The comparison of control and treated plots showed that irrigation water was saved up to 58 mm and discharge water was reduced up to 110 mm. The filtration outlet improved the discharge water quality for SS, COD, TN and TP up to 60.1 %, 0.1 %, 4.5 %, and 26.0 %, respectively. Overall, the findings of this study indicated that non-point source pollution discharged from paddy fields where automatic inlet and filtration outlet were installed could be reduced 266.3 kg/ha/yr in SS, 10.3 kg/ha/yr in COD, 1.22 kg/ha/yr in TN, and 0.10 kg/ha/yr in TP, respectively. This clearly showed that the automatic inlet and filtration outlet are effective management method for saving of agricultural water and protecting water environment.

펄스전원장치를 이용한 수산화 가스 발생 특성 연구 (A Study on the Generating feature of Hydrogen Oxygen Gas Using Pulse Power Supply)

  • 양승헌;김경현;전윤석;목형수;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.89-93
    • /
    • 2002
  • Hydrogen - Oxygen gas has obtained from water electrolysis reaction. It is mixed gas havingconstant volume ratio 2:1 Hydrogen and Oxygen, and it is used as a source of thermal energy by combustion reaction. This gas has betterristics in the field of economy, efficiency of energy, and environmental intimacy than used both of acetylene gas and LPG for gas welding machin. So nowdays many studies of Water-Electrolyzed gas are progressed, and commercially used as a source of thermal energy for gas welding In the industry. For Water-Electrolyzed Source, it was used diode rectifier or SCR rectifier for get DC source. This method which is not looking to improve a source for impossible current control or voltage and limited control intervals. In this paper, it was relized and designed in source of pulse type for complementing existing-DC source type, also by experiment it was acquired producting characteristics of Hydrogen -Oxygen Gas through feature of source

  • PDF

국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구 (A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System)

  • 양찬우;강희정;오세왕;도우빈;이광호;최종웅;조용;최종민
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.

주암댐 유역 비점오염부하량 우심지역 평가를 통한 오염물질 저감시설 최적 설치지점 선정 연구 (Assessment of Apprehensive Area of Non-Point Source Pollution Using Watershed Model Application in Juam Dam Watershed)

  • 이혜숙;최광순;정선아;이승재
    • 대한환경공학회지
    • /
    • 제37권10호
    • /
    • pp.551-557
    • /
    • 2015
  • 본 연구는 주암댐 유역을 대상으로 구축된 HSPF 결과를 활용하여 각 소유역별 비점오염원 부하량을 산정하여 비교함으로써 비점오염저감시설 우선 설치 대상지점을 평가하였으며 2011~2012년 BOD, TN, TP를 대상으로 모델 재현성을 검토된 결과를 활용하였다. 소유역별 비점오염부하량을 산정하여 비점오염저감시설 우선 설치 대상지점을 평가한 결과, BOD의 경우에는 2011년 평균 $8.8kg/day/km^2$, 2012년 평균 $9.1kg/day/km^2$, TN은 2011년 평균 $9.7kg/day/km^2$, 2012년 평균 $10.1kg/day/km^2$, TP는 2011년 평균 $0.30kg/day/km^2$, 2012년 평균 $0.33kg/day/km^2$으로 산정되었고, 보성강 상류에 위치한 소유역에서 상대적으로 높은 부하량이 유출되는 것으로 분석되었다. 특히, 봉화천 유역이 가장 우선순위가 높게 평가되었으며 미력천, 장평천, 율어천, 구암천, 석교천, 문덕천, 인천천, 봉내천 등의 순서로 평가되었으며 대체적으로 농업지역의 비율이 큰 소유역의 우선순위가 높은 것을 확인할 수 있었다.