Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.

An Assessment of the Secondary Neutron Dose in the Passive Scattering Proton Beam Facility of the National Cancer Center

  • Han, Sang-Eun;Cho, Gyuseong;Lee, Se Byeong
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.801-809
    • /
    • 2017
  • The purpose of this study is to assess the additional neutron effective dose during passive scattering proton therapy. Monte Carlo code (Monte Carlo N-Particle 6) simulation was conducted based on a precise modeling of the National Cancer Center's proton therapy facility. A three-dimensional neutron effective dose profile of the interior of the treatment room was acquired via a computer simulation of the 217.8-MeV proton beam. Measurements were taken with a $^3He$ neutron detector to support the simulation results, which were lower than the simulation results by 16% on average. The secondary photon dose was about 0.8% of the neutron dose. The dominant neutron source was deduced based on flux calculation. The secondary neutron effective dose per proton absorbed dose ranged from $4.942{\pm}0.031mSv/Gy$ at the end of the field to $0.324{\pm}0.006mSv/Gy$ at 150 cm in axial distance.

플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발 (Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector)

  • 곽동훈;고태영;이승호
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.638-644
    • /
    • 2018
  • 본 논문에서는 플라스틱 Scintillator와 NaI(TI) 검출기를 이용하여 움직이는 차량 적재물에 존재하는 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템을 제안한다. 제안하는 시스템은 방사선량 측정용 플라스틱 Scintillator, 2채널 펄스 카운터, 핵종 분석용 NaI(TI) 검출기 및 1채널 MCA Board 등으로 구성된다. 방사선원 위치판별 알고리즘은 방사선량의 거리의 자승에 반비례한 특성($1/r^2$)과 장치와의 각도(${\theta}$)에 따른 보상을 통해 계산된 방사선원의 CPS 값의 비율을 SVM 분류를 통하여 방사선원의 위치(X, Y)를 구할 수 있다. (Z) 좌표 값은 단위 시간당 움직이는 대상체의 속도에 따라 정해지게 되며 이는 단위주기당 백그라운드 스펙트럼을 제외한 순수 핵종의 스펙트럼을 분석한 후 핵종 유무 판별을 진행한 뒤 해당 핵종의 위치를 판별하게 된다. 본 논문에서 제안한 시스템의 위치 판별 실험 결과 ${\pm}1m$ 이내의 국제표준오차를 나타내었다. 따라서 본 논문에서 제안한 시스템의 유효성이 입증되었다.

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF

수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계 (A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization)

  • 김근섭;김덕영;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

무질서한 매질에서 침투깊이와 파동 전파 (Penetration depth and Wave Propagation in Random Media)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.

혼탁 매질에서 광산란에 의한 광학적 파라미터들의 측정에 관한 연구 (Studies on the Measurements of Optical Parameters in Turbid Material by Light Scattering)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.151-156
    • /
    • 1995
  • The influences of fluorophor, scatterer, absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by laser induced fluorescence spectroscopy. It has been found that the effects of optical properties in scattering media by the optical parameters(${\mu}_{s}$, ${\mu}_{a}$, ${\mu}_{t}$). The value of scattering coefficient ${\mu}_{s}$ is large by means of the increasing particles of scatterer, it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, laser medicine and application of medical engineering.

Spectral-Domain 광 계측을 위한 CCD 이미지 센서 드라이버 제작 (Realization of CCD Image Sensor Driver for Spectral-Domain Optical Measurement System)

  • 김훈섭;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.125-128
    • /
    • 2007
  • This paper presents Spectral-Domain optical measurement system using self-fabricated CCD sensor driver. The light source is a high brightness white LED and the detector is a 2048 array typed CCD image sensor. I have fabricated the CCD sensor driver to generate four pulse signals, which are the CCD-driving pulses. Using this Spectral Domain optical measurement system, the distance value between the reference mirror and the sample mirror can be obtained successfully.

  • PDF

시간 분해 반사율 측정에 의한 다중산란 매질의 광학 계수 측정 (Measurements of Optical Constants of Biomedical Media Based on Time-Resolved Reflectance)

  • 전계진;박승한;김웅;윤길원;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.235-239
    • /
    • 1996
  • In recent years, the optical properties of multiple-scattering media like tissue have been studied for their potential applications in medicine. In this work the optical properties of multiple scattering media were investigated using the time-resolved reflectance measurement. The reflected light was measured by time-correlated single photon counting system. The transport scattering and absorption coefficient are related to the initial rapid decay and the subsequent decay in reflected light, respectively. Also the optical properties of the samples were measured by conventional method, ie., using continuous wave light. When the distance between the light source and the detector is over 8mm, the optical coefficient can be measured accurately using the suggested method.

  • PDF

표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향 (The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate)

  • 오주영;김정열;오기백;오신현;김재삼;이창호;박훈희
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.53-61
    • /
    • 2013
  • 방사성 요오드 갑상선 섭취율은 거대갑상선 환자의 경우 그 체적에 의한 유효 갑상선 깊이가 깊어짐으로 인한 기하학적 변동이 있는 것이 사실이다. 본 연구는 방사성 요오드갑상선 섭취율에 있어 검출기와 선원 간 거리와 유효 갑상선 깊이에 따른 기하학적 요인의 영향을 고찰하고자 하였다. $^{131}I$ 370 kBq 선원을 검출기로부터 거리를 20 cm부터 30cm까지 1 cm 간격으로 변화시키며 Captus 3000 thyroid uptake system(Capintec, NJ, USA)으로 측정하였다. 유효갑상선 깊이를 재현하기 위해 목 팬텀을 이용하여 팬텀 내 선원의 깊이를 1 cm, 2 cm, 5 cm으로 변화시키며 같은 방법으로 측정하였다. 실험 결과, 곡선추정 회귀분석 결과 모든 실험군이 거듭제곱곡선에 높은 상관관계를 보이는 것으로 나타났다($$R2{\geq_-}0.915$$). 그러므로 검출기-선원 간 거리가 20 cm보다 30 cm에서 오차가 크게 감소됨을 예상할 수 있다. 모든 실험군에서 팬텀을 쓰지 않았을 때와 유효 갑상선깊이가 1 cm이 적용되었을 때의 계수율이 서로 유의할 만한 차이가 있는 것으로 나타났다(p<0.01). 선형회귀분석 결과 깊이에 따른 계수율의 변화는 모두 감소되는 것으로 나타났으나,$284.3keV{\pm}10%$ 영역에서 깊이에 따른 계수율의 변화는 증가되는 것으로 나타났다. 이 회귀식을 통해 환자의 예상 갑상선 섭취율을 산출해 보았을 때, $364.4keV{\pm}10%$에서 1 cm 당 -6.42%, $364.4keV{\pm}20%$의 영역에 서 -5.09%의 더 낮은 오차를 보였다. 또한 거리에 따른 계수율의 변동계수는 모든 실험군에서 선형으로 증가되는 것으로 나타났다. 그 중 $364.4keV{\pm}20%$, $364.4keV{\pm}10%$ 영역은 비교적 낮은 변동계수와 증가폭을 보였다. 곧, 유효 갑상선 깊이에 따른 오차를 줄이기 위해서는 $364.4keV{\pm}20%$의 영역의 사용이 더 적절할 것으로 보인다. 그러므로 갑상선 깊이에 따른 오차는 갑상선 깊이에 따른 보정계수 적용,$364.4keV{\pm}20%$ 에너지 영역 설정, 디텍터와 선원과의 거리를 연장하였을 때 감소시킬 수 있다고 생각된다.

  • PDF