• 제목/요약/키워드: sound spectrum

검색결과 305건 처리시간 0.023초

Fabry-Perot형 광섬유 배열센서의 방전 음압 계측 (Sound Measurements of the Discharge Break Down Using Fabry-Perot Sensor Array)

  • 이종길;이준호;이진우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.770-773
    • /
    • 2003
  • To measure discharge breakdown acoustic signal, Fabry-Perot interferometer fiber optic sensor is used. Fiber optic sensor array can measure the partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Fabry-Perot interferometer is selected as an fiber optic sensor array. It is shown that Fabry-Perot fiber optic sensor array detected discharge breakdown acoustic signal, effectively.

  • PDF

180도 원형 곡관에서 유동소음에 대한 실험적 연구 (An Experimental Study on flow Noise in a 180 Degree Circular Tube)

  • 장태현;이상배
    • 한국가시화정보학회지
    • /
    • 제7권1호
    • /
    • pp.29-34
    • /
    • 2009
  • During the past three or four decades, the characteristics of turbulent flow have been studied extensively because of their scientific and academic importance. This research deals with the periodic flow oscillation without swirling flow in a 180 degree circular tube using hot wire anemometry, microphone and accelerometer. The frequency regions are observed through the structured oscillation from spectrum. This work carried out to measure the sound level for each Reynolds number, $6{\times}10^4$, $8{\times}10^4$ and $1{\times}10^5$ respectively at the test tube without swirl flow.

발전소의 대형 주증기배관의 진동 특성 (The Vibration Characteristic of Large Main Steam Pipelines in Power Plant)

  • 김연환;이현
    • 소음진동
    • /
    • 제6권6호
    • /
    • pp.709-715
    • /
    • 1996
  • In recent years, the piping vibration in many Power Plants is being increased by the aged generating facilities due to a long time use. Generally, the pressure fluctuations associated with the flow-induced excitations in this case are broadband in nature. Mainly, the dominant sources of vibration are a vortex-shedding, plane waves and boundary layer turbulence. The peak level of the spectrum is proportional to the dynamic head. A severe disturbance in pipeline results in the generation of intense broadband internal sound waves which can propagate through the piping system. The characteristic frequencies of operating loads of 20%, 57%, 70%, 100% are 4 - 6 Hz and coincide with the results from impact hammering test and FEM analysis. We chose the wire energy absorbing rope restraint as a vibration reduction method after reviewing the various conditions such as site, installing space and economic cost etc. After installation, the vibration level was reduced about 54% in velocity.

  • PDF

모음 주파수 범위에 따른 성문전도 스펙트럼 기울기 (Electroglottographic Spectral Tilt in Frequency Ranges of Vowel Sound)

  • 김지혜;장애란;정동근
    • 센서학회지
    • /
    • 제24권4호
    • /
    • pp.247-251
    • /
    • 2015
  • In this study, electroglottographic spectral tilt (EST) was investigated for characterization of vocal cords vibration. EST was analyzed from the power spectrum of electroglottographic signals by dividing frequency analysis range as full range (0~4 octave), low range (0~2 octave), and high range (2~4 octave). EST of all ranges in female were greater than those in male. In female and male groups, EST of high range was higher than that of low range. This result suggests that EST has at least two components and dividing frequency range in analysis of EST is effective for investigating characteristics of vocal cords vibration.

송전선의 항력저감 및 소음에 관한 수치 연구 (Numerical Study for Drag and Noise Reduction of Electrical Cable)

  • 윤태석;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1716-1720
    • /
    • 2000
  • To develop the code of predicting flow-field and aeroacoustic noise by a electrical cable, a combined CFD-acoustic analogy approach is selected. The two-dimensional, unsteady, incompressible Reynolds-Averaged Navier-Stokes solver with a ${\kappa}{\omega}$, ${\kappa}{\omega}$ SST turbulence modeling is used to calculate the near-field around electrical cable. Near-field results are then coupled with two-dimensional Curle's integral formulation based upon Lighthill's acoustic analogy with an assumption of acoustic compactness. To validate this code, numerical results are compared with experimental data for a circular cylinder. The simulation shows an overprediction on acoustic amplitudes, but overally speaking, the spectrum pattern of sound pressure agrees well with experiment in an acceptable amount of error. In addition, various cross sections of a cable were selected and compared with each other in terms of drag and radiated noise.

  • PDF

Analysis of Fault Signal in Gear Using Higher Order Time Frequency Analysis

  • Lee, Sang-Kwon
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.268-277
    • /
    • 1999
  • Impulsive acoustic and vibration signals within gear are often induced by impacting of fault tooths in gear. Thus the detection of these impulses can be useful for fault diagnosis. Recently there is an increasing trend towards the use of higher order statistics for fault detection within mechanical systems based on the observation that impulsive signals then to increase the kurtosis values. We show that the fourth order Wigner Moment Spectrum, called the Wigner Trispectrum, has found superior detection performance to second order Wigner distribution for typical impulsive signals in a condition monitoring application. These methods are also applied to data sets measured within an industrial gear box.

  • PDF

환경통계 작성체계의 방법론적 연구 (A Study on Methodology of Framework for Development of Environmental Statistics)

  • 강상목
    • 환경영향평가
    • /
    • 제6권1호
    • /
    • pp.135-149
    • /
    • 1997
  • Environmental issues are currently in the forefront of the political and economic area both globaly and nationally. In the all spheres of socio-economic development and policy, it is suggested that there are need, to measure environmental impacts and to produce and disseminate environmental statistics systematically for environmentally sound and sustainable development. Specially, because environmental statistics encompass a wide spectrum of sectors from the natural to the social sciences and are dispersed among various agencies, an organized approach and compilation methods in complicated fields such as environment are required. This article includes the methodology on the framework for development of environmental statistics to advance korean environmental statistics.

  • PDF

트리잉 파괴에 따른 전기 및 AE신호의 분석 (Analysis of Electrical and AE Signals by Treeing Breakdown)

  • 이상우;김성규;김인식;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2335-2337
    • /
    • 1999
  • In this paper, using AE (Acoustic Emission) sensor the electrical and emitted-sound signals are measured by treeing breakdown in the epoxy resin, and the corresponding frequency spectrum of the AE signals are analyzed. We also examined the relationship between partial discharge magnitude and pulse number of AE signals to diagnose the deterioration of the electrical insulation due to treeing breakdown. From these results, a frequency band of AE signals through treeing breakdown was set to about 230 [kHz], and it appeared that pulse number of AE signal was proportional to partial discharge magnitude.

  • PDF

횡류팬 흡입구의 위치가 성능 및 소음 특성에 미치는 영향 (The Influence of the Intake Regions of the Cross-flow fan on the Performance and Fan Noise)

  • 김진백;최원석;이재권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.78-82
    • /
    • 2004
  • The cross-flow fan which is used for air-conditioner indoor units were studied experimentally. The recent trend shows that the room air-conditioners need to be good-looking. According to the visual design concepts the intake regions of the fan can vary, which leads to the loss of the performance and the increase of the noise of the fan. In order to optimize the performance of the fan and minimize the aerodynamic noise for the system, the performance characteristics and the noise of the cross-flow fan have been investigated at the various conditions of the intake region of the unit.

  • PDF

왕복동 압축기의 고주파수 대역 소음 저감 (Noise Reduction of a Reciprocating Compressor in a High Frequency Range)

  • 이진우;이제원;주재만
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.521-526
    • /
    • 2004
  • This paper introduces works performed for reducing high frequency noise of a reciprocating compressor. Noise in a high frequency range strongly affects sound quality as well as increases total noise level of the compressor. In order to reduce the noise, two different works were carried out. the first work was to measure the vibration Power transferred through suspension spring and discharge pipe; and the second one was to obtain operational deflection shape from cross-power spectrum measured on shell. Based on the information, Adequate structural modification of the transfer path and shell resulted in noise reduction in a high frequency range.

  • PDF