• Title/Summary/Keyword: sound insulation

Search Result 454, Processing Time 0.022 seconds

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship (고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구)

  • Joo, Won-Ho;Song, Keun-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

A Study on the Characteristics of Propagation and Attenuation of Piling Noise by SIP Method with Casing (Casing 부착 SIP공법에 의해 발생하는 항타소음의 전달 및 감쇠특성에 관한 연구)

  • 이병윤;윤해동;조원희;김재수
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.899-905
    • /
    • 1999
  • Construction equipment noise has caused much annoyance for a number of dwellers in nearby construction field and has become a very serious issure in our living environment. Therefore, in our country, a practical solution and a better method of reducing construction equipment noise are highly required in construction field. Practical solutions for the construction equipment noise, however, are very difficult because of the poorness of basic data and insufficiency of the existing research. Especially, in order to establish the sound insulation plan about pilling works noise with high sound pressure level and impactive, a real situation of sound characteristics about the noise of pilling works in foundation work demands more detail investigation. In this point, this study attempts to survey the characteristics of attenuation and propagation of construction equipment noise in pilling work using SIP(soil-cement injected precast pile) method with casing. And this study intends to get the basic data for establishment of a standard about construction noise.

  • PDF

Mechanical and Electrical Properties of Insulation System used in Generator Stator Windings (발전기 고정자 권선에 사용되는 절연재료의 기계적 및 전기적 특성)

  • Kim, Hee-Dong;Park, Jong-Jeong;Kim, Hee-Gon;Kang, Dou-Yol;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1376-1378
    • /
    • 1997
  • Mechanical and electrical properties of mica/epoxy composite materials were investigated by dynamic mechanical analyzer(DMA) and dielectric analysis (DMA). Both modulus and permittivity of sound specimens were higher than those of aged specimens. Two results show that $tan{\delta}$ of sound specimens is lower than that of aged specimens. DMA results showed that glass transition temperatures of sound and aged specimens are observed to be $87.16^{\circ}C$ and $88.38^{\circ}C$, which increases with the increase of aging time.

  • PDF

Considerations on the Factors Reducing the Sound Transmission Loss of the Honeycomb Panels (허니콤재의 투과손실 저하 인자에 대한 고찰)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Jung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2185-2190
    • /
    • 2008
  • In a high speed train, multi-layered panels for floor, side wall and roof are important sound insulating part. As these multi-layered panels require high bending strength vs. weight, corrugated steels or aluminium honeycomb panel are generally used. However, with some inevitable factors, these panels show lower sound insulation performance than that of the plate with the same weight. Transmission loss(TL) often severely decreases in a particular frequency range because of the decrease of the critical frequency, occurrence of local resonance modes and cavity resonance modes, which are not shown in a plate. In this study, frequency range and cause of the TL drop are investigated on the corrugated and honeycomb panels.

  • PDF

Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings (공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용)

  • Seo, Sang-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.385-388
    • /
    • 2005
  • Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

  • PDF

A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness (차음성능과 기밀성능이 향상된 경량 간막이벽 개발)

  • 배상환;박진우;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF

An Experimental Study on the Characteristics of Attenuation and Propagation of Pilings Noise by SIP Method in Construction Field (SIP공법에 의한 항타소음의 전달 및 감쇠특성에 관한 실험적 연구)

  • 이병윤;김병주;박재영;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.227-236
    • /
    • 1997
  • Construction equipment noise has caused much annoyance for a number of dwellers in nearby construction field and has become a very serious issue in our living environment. Therefore, in our country, a practical solution and a better method of reducing construction equipment noise are highly required in construction field. Practical solutions for the construction equipment noise, however, are very difficult because the poorness of basic data and insufficiency of the existing research. Especially, in order to establishment of sound insulation plan about pilings work noise that has highly sound pressure level and impactive, a real situation of sound characteristics about pilings work noise in foundation work demands close investigation. In this point, this study attempts to surveys the characteristics of attenuation and propagation of construction equipment noise in pilings work using SIP(soilcement injected precast pile) method. And this study intends to get the basic data for establishment of a standard about construction noise.

  • PDF

Estimation on the Interior and Outside Aircraft Noise Level of Residential House (주거용 건물의 실내.외 항공기소음레벨 평가)

  • Bang, Min;Kim, Do-Heong;Kim, Heung-Sik;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.687-691
    • /
    • 2007
  • It is important to increase the sound proof performance of building for reducing the influence of aircraft noise on the bais of actual survey of existed buildings. The purpose of this study is to propose the basic data for designing sound insulation of residential house. In this study, field measurement of aircraft noise Interior and outside noise level difference were carried out for 7 days in 2 residential houses. As the result, aircraft noise levels showed to be Leq $71.8{\sim}74.5$dB(A), WECPNL $82.2{\sim}83.4$ and indoor noise level were NC-55 ${\sim}63$ over acceptable NC-30 in 2 measured houses. Noise reduction effect showed to be $15.8{\sim}23.1$dB(A) in measured houses, and houses with double window were preferable to those with single window in sound proof performance. The outside sound pressure level for residential house was a little different according to the type of source. In measuring by using aircraft noise it was effected by angle and distance from measuring point, to aircraft, window area, and sound absorption of room, and so on.

  • PDF

Prediction Model of the Sound Transmission Loss of Honeycomb Panels for Railway Vehicles (철도차량용 허니콤재의 차음성능 예측모델)

  • Kim, Seock-Hyun;Paek, In-Su;Lee, Hyun-Woo;Kim, Jeong-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.465-470
    • /
    • 2008
  • Sound transmission characteristics are investigated on the honeycomb panels used for railway vehicles. Equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss (STL) of the honeycomb panels. The predicted values of the STL are compared with the measured values. The reliability and the limitation of the prediction models are investigated. Coincidence effect and local resonance effect on STL are considered. The result of the study shows that the equivalent orthotropic plate model can be used as a good prediction model, if the local resonance frequency is properly applied. finally, ways to improve the severe STL drop by local resonance are proposed and the effect on the sound insulation performance is analysed.