• Title/Summary/Keyword: sound absorption peak

Search Result 8, Processing Time 0.021 seconds

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

Investigation of Sound Absorption Ability of Acanthopanax senticosus Wastes

  • Eun-Suk, JANG
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.6
    • /
    • pp.404-413
    • /
    • 2022
  • This study aims to investigate the sound absorption ability of Acanthopanax senticosus wastes as an eco-friendly sound-absorbing material. The sound absorption coefficient was examined with different heights of A. senticosus wastes filling (40, 60, 80, and 100 mm) in impedance tubes. The sound absorption peaks shifted to a lower frequency as the height of A. senticosus wastes inside the tubes increased. The sound absorption ability at filling heights of 80 and 100 mm was obtained as 0.3M and 0.5M grades, respectively, based on KS F 3503. The results suggest that A. senticosus wastes exhibit good sound absorption ability and can therefore be used as an efficient, eco-friendly sound-absorbing material.

Use of Pine (Pinus densiflora) Pollen Cones as an Environmentally Friendly Sound-Absorbing Material

  • JANG, Eun-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.3
    • /
    • pp.186-192
    • /
    • 2022
  • This study examined the utility of pine (Pinus densiflora) pollen cones as an environmentally friendly material with sound-absorbing properties. Pine pollen cone samples with widths of 0.8-1.2 cm and lengths of 3.5-4.5 cm were prepared. After filling impedance tubes to heights of 6, 8, 10, or 12 cm with the pine pollen cones, the sound absorption coefficient of the pine pollen cones was investigated. The peak sound absorption frequency of the samples with a thickness of 6 cm was reached at 1,512 Hz; however, this value shifted to 740 Hz in samples with a thickness of 12 cm. Therefore, the sound-absorbing performance of pine pollen cones at low frequencies improved as the material thickness increased. According to KS F 3503 (Korean Standards Association), the sound absorption grade of pine pollen cones ranges from 0.3 to 0.5 M, depending on the material thickness of the pine pollen cones. In conclusion, the pine pollen cones demonstrated good sound absorption properties. They, thus, may be considered an environmentally friendly sound-absorbing material.

Noise Barrier Design for Increased Sound Absorption (흡음률 증가를 위한 방음벽 구조)

  • Kim Hyun-Sil;Kim Jae-Seung;Kang Hyun-Joo;Kim Bong-Ki;Kim Sang-Ryul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.367-370
    • /
    • 2001
  • Various shapes of the noise barrier frame and construction of the sound absorbing panels are studied. It is found that insertion of the sound absorbing panel into barrier frame results in the decrease of the sound absorption coefficient, while the empty frame shows a peak around 250Hz. Using double sound absorbing panels with air gap can increase sound absorption coefficient up to NRC 0.85.

  • PDF

Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure (높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계)

  • Park, Soon-Hong;Seo, Sang-Hyun;Jang, Young-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.

An Experimental Study on Acoustic Absorption in a Model Chamber with a Half-Wave Resonator (반파장 공명기를 장착한 모형연소실의 흡음특성에 대한 실험적 연구)

  • Sohn, Chae-Hoon;Park, Ju-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.34-40
    • /
    • 2008
  • Acoustic design parameters of a half-wave resonator are studied experimentally for acoustic stability in a model chamber. According to the standard acoustic-test procedures, acoustic-pressure signals are measured. Quantitative acoustic properties of damping factor and sound absorption coefficient are evaluated and thereby, the acoustic-damping capacity of the resonator is examined. The diameter and the number of a half-wave resonator, its distribution, and the diameter of an enclosure are selected as the design parameters for optimal tuning of the resonator. Aroustic-damping capacity of the resonator increases with its diameter. When the open-area ratio of the resonator exceeds the optimum value, over-damping appears, leading to the decrease in the peak absorption coefficient and the broadening of absorption bandwidth. As the resonator diameter increases, optimum open-area ratio decreases.

Thermal stabilityof fluorine doped silicon oxide films

  • Lee, Seog-Heong;Yoo, Jae-Yoon;Park, Jong-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 1998
  • The reliability of fluorine doped silicon oxide (SiOF) films for intermetal dielectrics in multilevel interconnections of ultra-large scale integrated circuits (ULSIs) is investigated. SiOF films were deposited by electron cyclotron resonance plasma-enhanced chemical vapor deposition (ECRPECVD) using H-free source gases, i.e., SiF4 and O2. The effect of post plasma treatment on the moisture absorption and dielectric properties of SiOF films was carried out I terms of air exposure time, The reliability test of Cu/TiN/SiOF/Fi specimen was carried out in terms of temperature by rapid thermal annealing (RTA) in N2 ambient. After O2 plasma treatment,, no appreciable peak directly related to moisture absorption was detected. The capacitance-voltage (C-V) characteristics of the O2 plasma treated SiOF film showed that the film remained to hold the sound dielectric properties even after boiling treatment. The Cu/TiN/SiOF/Si system was found to be reliable up to $600^{\circ}C$.

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.