• Title/Summary/Keyword: solvent system

Search Result 1,007, Processing Time 0.024 seconds

Pharmaceutical Potential of Gelatin as a pH-responsive Porogen for Manufacturing Porous Poly(d,l-lactic-co-glycolic acid) Microspheres

  • Kim, Hyun-Uk;Park, Hong-Il;Lee, Ju-Ho;Lee, Eun-Seong;Oh, Kyung-Taek;Yoon, Jeong-Hyun;Park, Eun-Seok;Lee, Kang-Choon;Youn, Yu-Seok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.4
    • /
    • pp.245-250
    • /
    • 2010
  • Porous poly(lactic-co-glycolic acid) microspheres (PLGA MS) have been utilized as an inhalation delivery system and a matrix scaffold system for tissue engineering. Here, gelatin (type A) is introduced as an extractable pH-responsive porogen, which is capable of controlling the porosity and pore size of PLGA microspheres. Porous PLGA microspheres were prepared by a water-in-oil-in-water ($w_1/o/w_2$) double emulsification/solvent evaporation method. The surface morphology of these microspheres was examined by varying pH (2.0~11.0) of water phases, using scanning electron microscopy (SEM). Also, their porosity and pore size were monitored by altering acidification time (1~5 h) using a phosphoric acid solution. Results showed that the pore-forming capability of gelatin was optimized at pH 5.0, and that the surface pore-formation was not significantly observed at pHs of < 4.0 or > 8.0. This was attributable to the balance between gel-formation by electrostatic repulsion and dissolution of gelatin. The appropriate time-selection between PLGA hardening and gelatin-washing out was considered as a second significant factor to control the porosity. Delaying the acidification time to ~5 h after emulsification was clearly effective to make pores in the microspheres. This finding suggests that the porosity and pore size of porous microspheres using gelatin can be significantly controlled depending on water phase pH and gelatin-removal time. The results obtained in this study would provide valuable pharmaceutical information to prepare porous PLGA MS, which is required to control the porosity.

Skin Permeability of piroxicam Gel by Phonophoretic Transdermal Drug Delivery (음파영동 경피약물수송에 의한 Piroxicam Gel의 경피투과)

  • Choi Suk-Joo;Oh Myung-Hwa;Kim Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.147-162
    • /
    • 2002
  • Transdermal permeation enhancer has been used to increased skin absorption. External control of drug release and skin absorption can also be achieved by iontophoresis or phonophoresis. However, because several problems with iontophoresis are that it has a risk to skin damage because of the change of pH and the increase of current density in applying it and that it can be applied only in the form of water solution, This study is to enhance drug permeation via skin following application of ultrasound. For this goal, in gel containing piroxicam, the degree of skin permeation in vitro and anti-inflammatory effect in in vivo were investigated. Permeation study using hairless mouse skin was performed at 37 $^{\circ}C$ using buffer saline as the receptor solution. The amount of piroxicam were quantified using a HPLC system consisting of solvent delivery system. Following adoption of ultrasound 1 MHZ, it showed relatively high permeation rate where it was compared with non treated by ultrasound. The influence of duty cycle having an effect on skin permeation rate was slight higher in the case of using pulsed mode. Skin permeation increase attended by intensity of ultrasound, the permeation of trice was accelerated at 2.0 W/$cm^{2}$ than 1.0 W/$cm^{2}$. The skin permeation of piroxicam was substantially influenced by ultrasound. Anti-inflammatory effects were determined using carrageenan-induced paw swelling method in SD rat. Paw swelling tests showed that pulsed phonophoresis group was more effective than control group and only gel application group. The conclusion of phonophoresis was found to improve significantly the skin permeation in vitro and the anti-inflammatory effect in vivo.

  • PDF

The Calculation of the Extraction Process for the Atmospheric Residue-pentane System (상압잔사유-펜탄계 추출공정 계산)

  • Baek, Il-Hyun;Kim, Choon-Ho;Min, Byoung-Moo;Hwang, Jong-Sic;Hong, Song-Sun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.220-229
    • /
    • 1997
  • Extraction of valuable light hydrocarbon from atmospheric residue using pentane as a solvent has been carried out. The SIMDIS was used to calculate the true boiling point of atmospheric residue containing complex components before the modeling of the extraction process could by performed. In order to simplify the procedure, modeling was adopted and a lumping method was used, such that a large number of compounds were divided into similar component classes called pseudocomponents. The modeling of the extraction process of the atmospheric residue-pentane system was based on the isothermal flash calculation, and the Peng-Robinson equation of state was used to calculate the fugacity coefficient of vapor and liquid phase during calculation steps of modeling. The agreement between the experiments and the calculations was reasonable considering the uncertainties involved in modeling such complex processes.

  • PDF

Fast Analytical Method of PCDD/Fs in Water by Combination of Disk Type Solid Phase Extraction and Column Coupling Chromatography (디스크타입 고상추출장치 및 컬럼커플링을 이용한 물시료의 PCDD/Fs 간이분석법)

  • Choi, Jae-won;Moon, Bu-shik;Kim, Kyoung-sim;Kim, Jung-hee;Kim, Sun-heong;Baek, Kyung-hee
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.879-886
    • /
    • 2006
  • The analytical methods of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans (PCDD/Fs) for water sample with extremely low concentration was developed to extract large volume and to improve fast chromatography for clean up. Semi-automated solid phase extraction (SPE) system and column coupling chromatography using elution pump was optimized and applied to each processes of treatment plant. Results of disk type SPE indicated that this system was applicable below 40 L of aqueous sample with a flow rate of 0.08 ~ 0.2 L/min. Average recoveries of SPE using labeled sampling spike of $^{37}Cl$-2,3,7,8-TCDD was 97%. Column coupling method resulted in reduced clean up time, solvent volume, increased average recoveries with constant elution rate. The combined methods were applied to the monitoring of drinking water treatment plant. Limits of detection (LOD) of each process were calculated. For example, LOD of raw and treated water ranged 0.094~0.968 pg/L and 0.028~0.364 pg/L, respectively. Combined methods of extraction and cleanup techniques provided fast analysis of PCDD/Fs with high accuracy and low LODs for water samples.

A Study of the Status of Occupational Health Management in Small-Scale Enterprises- Kwang-ju City and Chonnam Province - (소규모사업장 보건관리실태 연구 - 광주·전남 -)

  • Kim, Eun-Me;Park, In-Hye
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.55-65
    • /
    • 2001
  • The purpose of this study was to find out the status of occupational health management and the degree of recognition about the occupational health management of employees 248 small-scale enterprises which have been managed by the small-scale enterprises health care management support institution in 1999, were selected for study, in Kwang-Ju City. 98 employees were selected in 116 industries of them to grasp recognition of employees about the occupational health management. ► The Status of Occupational Health Management 1. Of the sample industries, 62.1 percent employed eleven to twenty-nine workers. Of the sample workers, 72.1 percent occupied workers who were engaged in the production line. 2. Environment evaluation was made on 82.7 percent of the sample industries and general exam made on 66.5 percent and specific health exam done on 73.4 percent. 3. The harmful factors in the sample industries were found to lie noise, dust, solvent, heavy metal, etc. 4. In general health exam 1,774 workers were participated and 148 workers got the result of above grade C and were diagnosed as having the problems with digestive system (63.6%), circulatory system(20.6%). etc. ► The Degree of Recognition about The Occupational Health Management of Employees. 1. Respondents were mainly in the twenties (42.9%), males(69.1%), duration of working period of five to ten years(24.0%), office workers(51.0%), monthly income under one million(55.7%). 2. Recognition of employees about the occupational health management consists of workplace environmental evaluation, health education, health exam and protector management. Their recognition on health education showed high score (mean 3.1), but generally the score was low(mean 2.9).

  • PDF

Preparation and Water Vapor Barrier Properties of PET/Nanohybrid PI Films (폴리에스테르/폴리이미드 나노복합필름의 제조 및 수분차단 특성)

  • Han, Seung San;Kim, Yong Seok;Won, Jong Chan;Lee, Jae Heung;Choi, Kil-Yeong
    • Journal of Adhesion and Interface
    • /
    • v.5 no.1
    • /
    • pp.29-35
    • /
    • 2004
  • We have prepared polyster/nanQhybridized polyimide films in the range of 1~9 wt% of organophilic synthetic layered silicate (STN). Firstly, poly(amic acid)/STN nanocomposite solutions were prepared via solution blending method in DMAc or THF/MeOH solution, and then cast on the polyester film followed by imidization reaction, thermal and chemical method repestively. XRD and TEM experiment showed that the STN was fully exfoliated through the polyimide matrix. Surface morphologies of nanohybridized polyimide films were characterized by AFM and thermal, mechanical properties were also confirmed by TGA, DMA and UTM each. And also, the water vapor permeabilities highly depended on the content of STN. The sample from chemical imidization route and THF/MeOH solvent system showed better water vapor barrier properties than thermal one and DMAc system.

  • PDF

Control of Particle Alignment in an Aqueous Colloidal System by an AC Electric Field (수계 콜로이드 계에서 교류 전계에 의한 입자 배열 제어)

  • Hwang, Yeon
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.13-17
    • /
    • 2013
  • The alignments of polystyrene particles of $1{\mu}m$ and $5{\mu}m$ sizes in an aqueous colloidal system were observed by varying the electric field strength, the frequency and the water flow. Spherical mono-dispersed polystyrene particles dispersed in pure water were put into a perfusion chamber; an AC electric field was applied to the Au/Cr electrodes with a 4 mm gap on the glass substrate. The mixture of the $1{\mu}m$ and $5{\mu}m$ sized polystyrene particles at 0.5 vol% concentrations for each size was set in the dielectrophoresis conditions of 1 kHz and 150 V/cm. Large particles of $5{\mu}m$ size were aligned to form chains as the result of the dielectrophoresis force interaction. On the contrary, small particles of $1{\mu}m$ size did not form chains because the dielectrophoresis force was not sufficiently large. When the electric field increased to 250 V/cm, small particles were able to form chains. After the chains were formed from both large and small particles, they began to coalescence as time passed. Owing to the electroosmotic flow of water, wave patterns along the perpendicular direction of the applied electric field appeared at the conditions of 200 Hz and 50 V/cm, when the dielectrophoresis force was small. This wave pattern also appeared for small particles at 1 kHz and 150 V/cm conditions due to the flow of solvent when water was forced to circulate.

Investigation into a Chemical Cracking and the Measurement of Stress in a Polycarbonate Specimen through Deformation Jig (변형지그를 이용한 폴리카보네이트 시편의 케미컬 크랙킹 및 응력측정에 관한 연구)

  • Yoo, Seo Jeong;Hong, Hyoung Sik;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.38 no.5
    • /
    • pp.645-649
    • /
    • 2014
  • The causes of residual stress in an injection molded part are high temperature variation and shear stress during molding process. Chemical cracking test is one of the methods of measuring residual stress and cracks are developed according to the degree of residual stress. In this study, the relationship between chemical cracking and exerted stress have been investigated. Deformation jig was designed and used to give a stress through deformation in a specimen. Specimens were molded by a hot press using polycarbonate (PC) and annealed to remove residual stresses in the specimens. Specimens were fixed in the deformation jig and immersed into the solvent to create cracks in the specimens. Solvents were prepared by using tetrahydrofuran and methyl alcohol. As stress accordance with the deformation in the specimen increased, the frequency and density of cracks in the specimen also increased. The results of this study can be used for the measurement of residual stress quantitatively in an injection molded PC product using a chemical cracking method.

Binding of Vaccine and Poly(DL-lactide-co-glycolide) Nanoparticle Modified with Anionic Surfactant (음이온성 유화제로 수식된 폴리락티드/글리코리드 공중합체 나노 입자와 백신의 결합성)

  • Choi, Min-Soo;Park, Eun-Seok;Chi, Sang-Cheol;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2004
  • Recently, studies on intranasal mucosa delivery of influenza vaccine have been actively developed because of lack of pain and ease of administration. We studied on preparation of nanoparticle delivery system using biodegradable polymer as a poly(DL-lactide-co-glycolide) (PLGA) and their binding characteristics with vaccine. Three kinds of PLGA nanoparticles were prepared by spontaneous emulsification solvent diffusion (SESD) method using sodium dodecyl sulfate and sodium laurate as an anionic surfactant and Lutrol F68 (polyethylene glycol-block-polypropylene glycol copolymer) as a nonionic surfactant. The 5-aminofluorescein labeled vaccine was coated on the surface of nanoparticles by ionic complex. The complexes between vaccine and nanoparticles were confirmed by change of the size. After vaccine coating on the surface of anionic nanoparticles, particle size was increased from 174 to 1,040 nm. However the size of nonionic nanoparticles was not more increased than size of anionic nanoparticles. The amount of coated vaccine on the surface of PLGA nanoparticles was $14.32\;{\mu}g/mg$ with sodium dodecyl sulfate, $12.41\;{\mu}g/mg$ with sodium laurate, and $9.47{\mu}g/mg$ with Lutrol F68, respectively. In conclusion, prepared nanoparticles in this study is possible to use as a virus-like nanoparticles and it could be accept in the field of influenza vaccine delivery system.

Preparation and characterization of nanoporous monolith with high thermal insulation performance (나노 기공성 단열 실리카 모노리스 제조 및 특성 연구)

  • Choi, Hyun-Muk;Kim, Seong-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • In this study, we synthesized two different silica monoliths by using sol-gel, solvent exchange, surface modification, ambient pressure drying processes, and surfactant-based templating technique followed by calcination process. All of the prepared two silica monoliths showed crack-free appearance with fairly good transparency, and furthermore were confirmed to have extremely high porosity, specific surface area, and mean pore size below 30 nm. The silica aerogel sample exhibited finer and more homogeneous nano-sized pore structure due to spring back effect caused by surface modification, which resulted in better thermal insulation performance. Based on measured thermal conductivities and theoretical relationship, multi-layered glass window system in which silica monolith prepared in this study was inserted as a middle layer was revealed to have superior thermal insulation performance compared to conventional air-inserted glass window system.