• 제목/요약/키워드: solid pulse

검색결과 192건 처리시간 0.026초

원주방향 슬릿을 가진 파열판의 매개변수 연구 (A Parametric Study on Rupture Disc with Radial Slit of Pulse Separation Device)

  • 한혁섭;조원만;이원복;구송회;이방업
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.261-264
    • /
    • 2010
  • 이중 펄스 로켓 추진기관은 하나의 연소관 안에 특성이 다른 2개의 추진제가 격벽에 의해 2개의 공간에 분리되어 있는 고체 추진기관이다. 유한요소법을 이용한 탄소성 동적거동해석에 의하여 펄스분리장치 파열판의 파열해석을 수행하였다. 원주방향 슬릿을 가진 파열판의 슬릿 크기를 변경한 해석을 수행하여 파열형상, 파열시점을 해석함으로써 슬릿의 설계 변수가 파열판에 미치는 영향을 검토하였다. 해석 결과는 펄스분리장치 파열판 슬릿 크기의 변경을 통한 파열압력의 조절에 사용할 수 있다.

  • PDF

Efficient keV X-ray Generation from Irradiation of in-situ Produced Silver Clusters by Ti:sapphire Laser Pulses

  • Chakravarty, U.;Naik, P.A.;Kumbhare, S.R.;Gupta, P.D.
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.80-85
    • /
    • 2009
  • An experimental study of energy absorption and x-ray emission from ultrashort laser pulse irradiation of in-situ produced solid clusters has been performed. Silver clusters produced by a 30 mJ, 300 ps laser pulse were irradiated up to an intensity of $3{\times}10^{17}\;W/cm^2$ by a 70 mJ, 45 fs compressed laser pulse from the same Ti:sapphire laser. Absorption of the laser light exceeding 70% was observed, resulting in an x-ray yield (>1 keV) of ${\sim}60{\mu}J$ pulse. This may constitute a much simpler means of intense x-ray generation using ultrashort laser pulses as compared to the irradiation of structured / pre-deposited cluster targets, and it offers higher x-ray conversion efficiency than that from gas clusters and planar solid targets.

펄스분리장치의 이중 슬릿형 파열판 매개변수 연구 (A Parametric Sturdy on Double Slit Type Rupture Disc of Pulse Separation Device)

  • 한혁섭;조원만;구송회;이방업
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.105-112
    • /
    • 2010
  • 이중 펄스 로켓 추진기관은 하나의 연소관 안에 특성이 다른 2개의 추진제가 격벽에 의해 2개의 공간에 분리되어 있는 고체 추진기관이다. 유한요소법을 이용한 탄소성 동적거동해석에 의하여 펄스분리장치 파열판의 파열해석을 수행하였다. 파열판의 슬릿 크기를 변경한 해석을 수행하여 파열형상, 파열시점을 해석함으로써 슬릿의 설계 변수가 파열판에 미치는 영향을 검토하였다. 해석 결과는 펄스분리장치 파열판 슬릿 크기의 변경을 통한 파열압력의 조절에 사용할 수 있다.

  • PDF

제모용 Long-Pulse Alexandrite Laser의 출력 특성 연구 (A study on the output characteristics of Long-pulse Alexandrite laser for hair removal)

  • 최진영;김상길;김태균;박종웅;송건주;정용호;홍정환;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1729-1731
    • /
    • 2003
  • Recently many solid-state laser systems were widely used in the medical applications. So it is necessary to study various optimal laser parameters for adopting new medical treatments. Alexandrite laser using switching mode power supply has designed and experimented to adjust a pulse repetition rate by PIC one-chip microprocessor. The fundamental results have been obtained during the first financial year in 2002. We will be able to find out the optimal hair removal characteristics by the repetitive experiments of Alexandrite laser as the parameters such as pulse repetition rate, pulse width, and pulse energy etc.

  • PDF

Variable Pulse Generation Technology of Pusle ND:YAG Laser Using Real Time Multi-Discharge

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.102.2-102
    • /
    • 2001
  • In this study, a solid-state laser system adopting a new real time multi-discharge (RTMD) method in which three flashlamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC one-chip microprocessor, With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

Numerical Simulation of Soliton-like Pulse Formation in Diode-pumped Yb-doped Solid-state Lasers

  • Seong-Yeon, Lee;Byeong-Jun, Park;Seong-Hoon, Kwon;Ki-Ju, Yee
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.90-96
    • /
    • 2023
  • We numerically solve the nonlinear Schrödinger equation for pulse propagation in a passively mode-locked Yb:KGW laser. The soliton-like pulse formation as a result of balanced negative group-delay dispersion (GDD) and nonlinear self-phase modulation is analyzed. The cavity design and optical parameters of a previously reported high-power Yb:KGW laser were adopted to compare the simulation results with experimental results. The pulse duration and energy obtained by varying the small-signal gain or GDD reproduce the overall tendency observed in the experiments, demonstrating the reliability and accuracy of the model simulation and the optical parameters.

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

어레이 압저항 센서를 활용한 체질맥 임상연구 (Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor)

  • 이시우;주종천;김경요;김종열
    • 사상체질의학회지
    • /
    • 제18권1호
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

펄스 도금법에 의한 메탄연료 직접 사용을 위한 Cu-Ni-YSZ SOFC 연료극 제조 및 특성평가 (Fabrication and Characterization of Cu-Ni- YSZ SOFC Anodes for Direct Utilization of Methane via Cu pulse plating)

  • 박언우;문환;이종진;현상훈
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.807-814
    • /
    • 2008
  • The Cu-Ni-YSZ cermet anodes for direct use of methane in solid oxide fuel cells have been fabricated by electroplating Cu into the porous Ni-YSZ cermet anode. The uniform distribution of Cu in the Ni-YSZ anode could be obtained via pulse electroplating in the aqueous solution mixture of $CuSO_4{\cdot}5H_{2}O$ and ${H_2}{SO_4}$ for 30 min with 0.05 A of average applied current. The power density ($0.17\;Wcm^{-2}$) of a single cell with a Cu-Ni-YSZ anode was shown to be slightly lower in methane at $700^{\circ}C$, compared with the power density ($0.28\;Wcm^{-2}$) of a single cell with a Ni-YSZ anode. However, the performance of the Ni-YSZ anode-supported single cell was abruptly degraded over 21 h because of carbon deposition, whereas the Cu-Ni-YSZ anode-supported single cell showed the enhanced durability upto 52 h.

Spiking Suppression of Quasi-continuous-wave Pulse Nd:YAG Laser Based on Bias Pumping

  • Chen, Yazheng;Wang, Fuyong
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.400-406
    • /
    • 2022
  • We numerically demonstrate that the inherent spiking behavior in the quasi-continuous-wave (QCW) operation of an Nd:YAG laser can be suppressed by adopting bias pumping. After spiking suppression, the output QCW pulses from a bias-pumped Nd:YAG laser are very stable, and they can maintain nearly the same temporal shape as that of pump pulse under different pump repetition rates and peak powers. Our study implies that bias pumping is an alternative method of spiking suppression in solid-state lasers, and the application areas of an Nd:YAG laser may be extended by bias pumping.