• Title/Summary/Keyword: solar heat system

Search Result 792, Processing Time 0.029 seconds

Numerical modeling of Atmosphere - Surface interaction considering Vegetation Canopy (식물계를 고려한 지표-대기 상호작용의 수치모의)

  • 이화운;이순환
    • Journal of Environmental Science International
    • /
    • v.3 no.1
    • /
    • pp.17-29
    • /
    • 1994
  • An one dimensional atmosphere-vegetation interaction model is developed to discuss of the effect of vegetation on heat flux in mesoscale planetary boundary layer. The canopy model was a coupled system of three balance equations of energy, moisture at ground surface and energy state of canopy with three independent variables of $T_f$(foliage temperature), $T_g$(ground temperature) and $q_g$(ground specific humidity). The model was verified by comparative study with OSUID(Oregon State University One Dimensional Model) proved in HYPEX-MOBHLY experiment. As the result, both vegetation and soil characteristics can be emphasized as an important factor iii the analysis of heat flux in the boundary layer. From the numerical experiments, following heat flux characteristics are clearly founded simulation. The larger shielding factor(vegetation) increase of $T_f$ while decrease $T_g$. because vegetation cut solar radiation to ground. Vegetation, the increase of roughness and resistance, increase of sensible heat flux in foliage while decrease the latent heat flux in the foliage.

  • PDF

A Study on Thermal Performance of the Heat Recovery Ventilator used Window (창호적용 배열회수 환기유닛의 열성능평가 연구)

  • Jang, Cheol-Yong;Cho, Soo;Sung, Uk-Joo;Lee, Jin-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.129-134
    • /
    • 2008
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. And, recently the use of heat recovery ventilator has increased rapidly for improvement of air Quality and energy saving in building. But, the high efficient heat exchange will be more increasable than water vapors which were only occurred residential active. Purpose of this study is measurement of thermal performance about heat-recovery system integrated window. The result of the window thermal resistance is 1.80 $W/m^2K$ by KS F 2278. Air tightness is 5.96 m3/m2h at 4 Pa by KS F 2292.

  • PDF

Economic Analysis of Renewable Heat Energy: Levelized Cost of Heat (LCOH) (재생열에너지 경제성 분석: 균등화열생산비용(LCOH))

  • Jaeseok Lee;Ilhyun Cho
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.52-60
    • /
    • 2024
  • This study conducted an economic analysis of renewable heat energy by estimating the levelized cost of heat production (LCOH) of ST and GSHP and comparing it with the cost of alternative fuels. The LCOH of ST ranged from 396.8 KRW/kWh to 578.7 KRW/kWh (small-scale), 270.3 KRW/kWh to 393.3 KRW/kWh (large-scale), and 156.3 KRW/kWh to 220.7 KRW/kWh for GSHP. The economic feasibility of ST and GSHP was analyzed by comparing the calculated LCOH and the fuel costs such as gas and kerosene prices. Moreover, scenario analyses were conducted for installation subsidies under the current system to examine the changes in the economics of renewable thermal energy.

A Study on Comparison of Heat Transfer Characteristic and Heat Storage Capability of $C_{28}H_{58}$ and $Na_4P_2O_7{\cdot}10H_2O$ ($C_{28}H_{58}$$Na_4P_2O_7{\cdot}10H_2O$의 전열특성 및 축열성능 비교에 관한 연구)

  • Yim, Chang-Soon;Kim, Jun-Keun;Cho, Nam-Cheol;Kim, Young-Ki
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.41-50
    • /
    • 1991
  • Heat transfer phenomena and temperature characteristics in heat storage and release process in the heat storage system using PCM(Phase Change material) were studied experimentally. The melting points of Octacosane paraffin($C_{28}H_{58}$) and sodium pyrophosphate decahydrate ($Na_4P_2O_7{\cdot}10H_2O$) used for phase change materials are $62^{\circ}C$ and $79^{\circ}C$ respectively. Experiments were performed in order to investigate temperature distributions, the heat storage quantity and the release quantity on octacosane paraffin and sodium pyrophosphate decahydrate for heat storage and release in the heat storage system. Furthermore the comparison of these characteristics between paraffin and $Na_4P_2O_7{\cdot}10H_2O$ were evaluated. In case of the paraffin, temperature slowly increased at early heat storage process by natural convection, while temperature of $Na_4P_2O_7{\cdot}10H_2O$ rapidly increased the dominant role played by conduction at early heat storage processing Also, during the heat storage and release process in case of the paraffin, it was observed that the variation of temperature of the neighborhood of wall and center in the top and bottom of the tube exhibited a great difference, however in $Na_4P_2O_7{\cdot}10H_2O$, it was observed that the variation of temperature exhibited a little difference. And heat storage quantity of each PCM of identity mass in heat storage process was shown that $Na_4P_2O_7{\cdot}10H_2O$ exhibited more by 16 percents than paraffin.

  • PDF

An Experimental Study on the Double Diffusive Thermohaline System (열-염분 이중확산계에 관한 실험적 연구)

  • Pak, Hi-Yong;Lim, Kyung-Bin
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.15-21
    • /
    • 1986
  • In this study, an experimental double diffusive thermohaline system heated from below was constructed and the phenomena of each layer developed in the system were observed. The experiment was performed with the initial salt concentration gradient of $-436.2kg/m^4$ and the net heat flux of approximately $176w/m^2$. An electroconductivity-temperature probe was made and used for the measurements of salt concentration. As the result of this study, it was found that the salt concentration decreased in the bottom mixed layer and increased in the top mixed layer during the experiment while the salt concentration gradient in the diffusive layer unchanged. It was also found that the interfacial boundary layers were due largely to variations in salt concentration rather than temperature.

  • PDF

Thermal Performance of Air Receiver filled with Porous Material for $5kW_t$ Dish Solar Collector (공기식 흡수기를 이용한 5kW급 접시형 태양열 집열기의 열성능 해석)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Kang, Yong-Heack;Lee, Sang-Nam;Han, Gui-Young
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.570-575
    • /
    • 2007
  • The thermal performance of the air receiver filled with porous material for 5kWt dish solar collector installed in Inha University, Korea, is experimentally investigated. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small pieces of glasses which have their own curvatures, and the effective reflecting area is 5.9 m2. The reflectivity of the glass is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakages. In order to increase the heat transfer area, porous material (nickel-alloy) is inserted into the receiver. Air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The thermal efficiency of the receiver ranges from 82% - 92% depending upon the flow rate. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected. These results from the experiment will be useful for the applications to air heating receivers and solar reactors.

  • PDF

An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing (공동주택의 기밀성능 평가 및 에너지 절감효과 분석)

  • Leigh, Seung-Bok
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.119-125
    • /
    • 1995
  • Since the using of heating energy associated with infiltration is significant in a building, the efforts to minimize the infiltration while ensuring minimum ventilation rates for various types of occupancy will be beneficial. In constrast to that many efforts have been made to reduce heat loss by improving thermal resistance of building envelope, little has been tried to reduce heat loss from infiltration. For achieving such an objective, measurement of air leakage rate will be pre-requisite as a diagnostic tool. A blower door system, a depressurization/pressurization method, was employed and it demonstrated a good potential for measuring airtightness performance of residential buildings. Based on the test results, annual energy savings for residential heating was estimated by reducing infiltration to a level of reasonably airtight or to a level of ASHRAE Standard 62-1989 for minimum ventilation.

  • PDF

A Study on Thermal Performance Evaluation with TAP (Thermosyphoning Air Panel) in Inside and Outside Insulated Constructions (TAP을 적용한 내단열과 외단열구조의 열성능 평가에 관한 연구)

  • Lee, Kyung-Hoi;Yoo, Ho-Chun;Hong, Yung-Woo;Chun, Chai-Hwi
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 1987
  • TAP system, a kind of natural convective space heating collector, has a good heat loss by night. The aim of this paper is to induce and to study an hourly heat flow theory by response factors analysis with TAP in inside and outside insulated construction, to compare and evaluate on thermal performance an hourly natural temperature, heated room temperature and heating load in aboved-mention constructions with computer simulation. The results of the study can be summarized as follows. According that there is no TAP and with TAP, it is inside insulated construction and outside insulated construction, daily natural range of temperature each shows $12.5^{\circ}C$ and $16.7^{\circ}C$, $2.7^{\circ}C$ and $3.7^{\circ}C$, daily heated range of temperature with noramal control heating system each shows $6.6^{\circ}C$ and $12.1^{\circ}C$, $1.7^{\circ}C$ and $3.1^{\circ}C$, heating hours each show 10 hr and 7 hr, 9 hr and 4 hr and heating energy saving percentage in january 123% and 79%, 100% and 40%. Therefore, energy saving percentage shows that outside insulated construction saves about 54% in comparision with inside insulated construction.

  • PDF

A Study on the Characteristics of CdS Thin Film by Annealing Time Change (열처리시간 변화에 의한 CdS 박막 특성에 관한연구)

  • Chung, Jae-Pil;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.438-443
    • /
    • 2021
  • This paper uses a multiplex deposition sputter system and aims to improve transmittance and reduce production costs by depositing a CdS thin film on an ITO glass substrate. When manufacturing CdS thin films, we wanted to find excellent conditions when manufacturing solar cells by changing heat treatment time. It was observed that thickness and sheet resistance were not significantly different depending on heat treatment time changes. The specific resistance was measured from a minimum of 6.68 to a maximum of 6.98. When the heat treatment time was more than 20 minutes, the transmittance was measured to be more than 75%. When the heat treatment time was 10 minutes, the bandgap was 3.665 eV and more than 20 minutes was 3.713 eV, which was measured as the same result. The XRD analysis showed that the structure of CdS was hexagonal and only CdS thin films were deposited without any other impurities. The result of calculating the FWHM was a maximum of 0.142 when the heat treatment time was 20 minutes, and a minimum of 0.133 when the heat treatment time was 40 minutes, so there was no significant difference in the FWHM when the heat treatment time was changed. The particle size was measured at 11.65 Å when the heat treatment time was 40 minutes, and at 10.93 Å when the heat treatment time was 20 minutes.

A Study for Thermoelectric Generator System And Caused Low Thermoelectric Power (열전발전량에 영향을 미치는 요인과 최적의 열전발전시스템에 관한연구)

  • Moon, Chae-Joo;Cheang, Eui-Heang;Lim, Jung-Min;Park, Sang-Jin;Kim, Tae-Gon;Kim, Young-Gu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.68-74
    • /
    • 2008
  • This paper describes the causes and effects that have influence on thermoelectric generation. If heat transfer is unequal to thermoelectric modules, we could not get the maximum thermoelectric power. So, by experiment, we analysed the differences of power generation according to the state of the contact between thermoelectric module and heat source. And with the variation of heat transfer area, the generated power was analysed also. Using the experimental results we proposed a thermoelectric generation system.

  • PDF