• Title/Summary/Keyword: solar heat system

Search Result 792, Processing Time 0.029 seconds

Mechanical and Thermal Characteristics of Cement-Based Composite for Solar Thermal Energy Storage System (태양열 에너지 저장시스템 적용을 위한 시멘트 기반 복합재료의 역학 및 열적 특성)

  • Yang, In-Hwan;Kim, Kyoung-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.9-18
    • /
    • 2016
  • The thermal and mechanical properties of fiber-reinforced cement-based composite for solar thermal energy storage were investigated in this paper. The effect of the addition of different cement-based materials to Ordinary Portland cement on the thermal and mechanical characteristics of fiber-reinforced composite was investigated. Experiments were performed to measure mechanical properties including compressive strength before and after thermal cycling and split tensile strength, and to measure thermal properties including thermal conductivity and specific heat. Test results showed that the residual compressive strength of mixtures with OPC and slag was greatest among cement-based composite. Thermal conductivity of mixtures including graphite was greater than that of any other mixtures, indicating favor of graphite for improving thermal transfer in terms of charging and discharging in thermal energy storage system. The addition of CSA or zirconium increased specific heat of fiber-reinforced cement-based composite. Test results of this study could be actually used for the design of thermal energy storage system in concentrating solar power plants.

PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method (IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구)

  • Pak, Jin-Woo;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

Development of Optimal Control of Heliostat System Using Configuration Factor and Solar Tracking Device (형상계수와 태양추적장치를 이용한 헬리오스타트 제어 시스템 개발)

  • Lee, Dong Il;Jeon, Woo Jin;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1177-1183
    • /
    • 2012
  • This study aims to develop a system that maximizes the radiative heat transfer from the heliostat to the receiver by using the configuration factor and a solar tracking device. As the heat transfer from the heliostat to the receiver is delivered by solar radiation, the configuration factor commonly utilized for radiation is applied to control the heliostat. Tracking the sun and calculating its position are possible by using an illuminance sensor (CdS) and Simulink. By applying optimized algorithms programmed using Simulink that maximize the configuration factors among the heliostat, receiver, and sun in real time, the solar absorption efficiency of the receiver can be maximized. Simulations were performed on how to change the angle required to control the elevation and azimuthal angle of the heliostat during the daytime with respect to various distances.

Design and Preliminary Performance Test for 5kWt Dish Solar Collector ($5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Han, Gui-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation (부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Ro, Jeong-Geun;Yon, Kwang-Seok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

Development of a System-Independent Mobile Smart Shelter using Solar Energy (태양광 에너지를 이용한 계통 독립형 이동식 스마트 쉼터 개발)

  • Joo, Jong-Yul;Lee, Young-Jae;Park, Kyoung-Wook;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1061-1068
    • /
    • 2020
  • This paper presents a system-independent mobile smart shelter using solar energy technology that can be freely installed in various places, such as parks, countryside, event area, construction area and walking tour places where the system power are difficult to use. The proposed smart shelter is equipped with solar power generation and energy storage devices that is combined with IoT technology to collect indoor and outdoor humidity, fine dust and tourist awareness in real time. It is possible to efficiently manage energy by performing the optimal energy operation during the heat- wave, cold-wave situation and the presence of travelers and it is possible to serve as a shelter for as long as possible without system power.

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices (실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구)

  • Kim, Tae-Jung;Kang, Jae-Sik;Park, Jun-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea (창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가)

  • Lim, Hee Won;Kim, Dong Yun;Lee, Soo Man;An, Jung Hyuk;Yoon, Jong Ho;Shin, U Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.