• 제목/요약/키워드: solar electricity

검색결과 484건 처리시간 0.026초

신재생에너지 보급량 예측을 위한 시스템다이내믹스 모델 개발 (The System Dynamics Model Development for Forecasting the Capacity of Renewables)

  • 김현실;고경호;안남성;조병옥
    • 한국시스템다이내믹스연구
    • /
    • 제7권2호
    • /
    • pp.35-56
    • /
    • 2006
  • Korea is implementing strong regulatory derives such as Feed in Tariff to provide incentives for renewable energy developers. But if the government is planning to increase the renewable capacity with only "Price policy" not considering the investors behavior in the competitive electricity market, the policy would be failed. It is necessary system thinking and simulation model analysis to decide government's incentive goal. This study is focusing on the assesment of the competitiveness of renewable energy with the current Feed in Tariff incentives compared to the traditional energy source, specially coal and gas. The simulation results show that the market penetration of renewable energy with the current Feed-in-Tariff level is about 60-70% of the government goal under condition that the solar energy and fuel cell are assumed to provide the whole capacity set in the governmental goal. If the contribution from solar and fuel cell is lower than planned, the total penetration of renewable energy will be dropped more. Notably, Wind power turned out to be proved only 10% of government goal because of its low availability.

  • PDF

대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가 (The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.

산업단지 에너지사용계획을 위한 표준데이터 산정 연구 (A Study on the Calculation of Standard Data for Energy Use Plan of Industry Complex)

  • 서광수
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.101-109
    • /
    • 2014
  • The Consultation about Energy Use Plan is prescribed by the Energy Use Rationalization Act. This study calculated the Standard Data for Energy Use Plan of Industry Complex by the 9th Korean Standard Industrial Classification Divisions so that the energy demand reflecting the industrial technology change and characteristics of Manufacturing Divisions would predict. To achieve this aim, analysis on thousands of data in Energy Consumption Report Forms reported from industries which annual consumption of energy exceeds 2,000toe from 2009 to 2010 was carried out. The results showed that calculated overall mean fuel basic unit decrease, electricity basic unit increase and energy basic unit increase compared to that of the Notification No. 2002-130 of the Ministry of Commerce, Industry and Energy, therefore it means that heat source of energy facilities transferred from fuel to electricity. Also resultingly suggests that the related notification, code etc. are amended as soon as possible.

대학건물의 에너지 소비 특성에 관한 사례분석 (A Case Study of Electric Power Consumption Characteristics in University Building)

  • 이왕제;이동원;이재범;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.90-95
    • /
    • 2012
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

대학건물의 전력소비 특성에 관한 사례분석 (A Case Study of Electric Power Consumption Characteristics in University Building)

  • 이왕제;윤종호;백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.282-287
    • /
    • 2011
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

  • PDF

제주지역 풍력발전 및 태양광발전의 전력계통 부하기여 분석 (Analysis of the Load Contribution of Wind Power and Photovoltaic Power to Power System in Jeju)

  • 명호산;김형철;강남호;김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제38권1호
    • /
    • pp.13-24
    • /
    • 2018
  • As part of the "Carbon free Island 2030" policy, the local government of Jeju Island is currently working to reduce carbon through renewable energy supply. However, renewable energy is difficult to predict due to intermittent characteristics. If the share of renewable energy increase, it is difficult to plan of supply of electricity to grid due to that characteristic of renewable. In this paper analyze the fluctuation rate and the capacity credit of wind power and PV to find out how much wind power and PV contribute to supply of electricity of power system in Jeju. As a result mean value of variation rate of wind power and PV is about 3%, 5% and capacity credit is about 10% and 2% respectively.

환경에너지 종합타운 조성 타당성에 관한 연구 (Study on Pertinence for Environmental Energy Complex Town Construction)

  • 김영준;이종연;강용태
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.164-171
    • /
    • 2011
  • The objectives of this study are to propose a suitable treatment facility for waste energy recovery after analyzing the waste generation and disposal situation in Jejudo, to establish the plan to install the solar photovoltaics and wind power plant considering the site conditions and finally to establish the environmental energy town plan in conjunction with the existing facilities. The food waste biogas plant is selected as the treatment capacity of 200 ton/day. It is estimated that the biogas plant will produce the electricity of 7,594 MWh per year, which will reduce the greenhouse gas of 4,177 $tCO_2$ per year. The solar photovoltaics and wind power plant will produce the electricity of 13,410 MWh per year, which will reduce the greenhouse gas of 7,375 $tCO_2$ per year. Environmental energy town will give us the reduction of operating cost by centralized treatment of residues and byproducts, and by efficient utilization of produced energy.

바이오매스 자원 잠재량 산정 (Estimation of Biomass Resources Potential)

  • 이준표;박순철
    • 한국태양에너지학회 논문집
    • /
    • 제36권1호
    • /
    • pp.19-26
    • /
    • 2016
  • Biomass has been used for energy sources from the prehistoric age. Biomass are converted into solid, liquid or gaseous fuels and are used for heating, electricity generation or for transportation recently. Solid biofuels such as bio-chips or bio-pellet are used for heating or electricity generation. Liquid biofuels such as biodiesel and bioethanol from sugars or lignocellulosics are well known renewable transportation fuels. biogas produced from organic waste are also used for heating, generation and vehicles. Biomass resources for the production of above mentioned biofuels are classified under following 4 categories, such as forest biomass, agricultural residue biomass, livestock manure and municipal organic wastes. The energy potential of those biomass resources existing in Korea are estimated. The energy potential for dry biomass (forest, agricultural, municipal waste) were estimated from their heating value contained, whereas energy potential of wet biomass (livestock manure, food waste, waste sludge) is calculated from the biological methane potential of them on annual basis. Biomass resources potential of those 4 categories in Korea are estimated to be as follows. Forest biomass 355.602 million TOE, agricultural biomass 4.019 million TOE, livestock manure biomass 1.455 million TOE, and municipal organic waste 1.074 million TOE are available for biofuels production annually.

MERRA 재해석 데이터를 이용한 중국 동하이대교 풍력단지 에너지발전량 예측 (Prediction of Energy Production of China Donghai Bridge Wind Farm Using MERRA Reanalysis Data)

  • 고월;김병수;이중혁;백인수;유능수
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.1-8
    • /
    • 2015
  • The MERRA reanalysis data provided online by NASA was applied to predict the monthly energy productions of Donghai Bridge Offshore wind farms in China. WindPRO and WindSim that are commercial software for wind farm design and energy prediction were used. For topography and roughness map, the contour line data from SRTM combined with roughness information were made and used. Predictions were made for 11 months from July, 2010 to May, 2011, and the results were compared with the actual electricity energy production presented in the CDM(Clean Development Mechanism)monitoring report of the wind farm. The results from the prediction programs were close to the actual electricity energy productions and the errors were within 4%.

건물의 전기부하특성에 따른 BIPV시스템의 부하매칭에 관한 연구 (A Study on BIPV system generation matching by electricity load characteristic of Building)

  • 박재완;신우철;김대곤;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.67-74
    • /
    • 2013
  • These days, although thermal energy is decreasing, electric energy is increasing in building. Also, it is very important to research and distribute BIPV(Building Integrated photovoltaic) because our society consider electricity more significant than other energy in building. Therefore, in this paper, our research team analyzed difference between BIPV yield and building energy consumption through experimental research. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV.