• Title/Summary/Keyword: soil temperature distribution

Search Result 227, Processing Time 0.03 seconds

Effects of the Freeze-thaw Process on the Strength Characteristics of Soils (IV) -Insulation Performance beneath the Freezed Tested Banking by Inclusion of Insulation Material- (동결-융해작용이 흙의 강도특성에 미치는 영향 (IV) - 단열재를 삽입한 동결성토의 단열거동 -)

  • 유능환;박승범;유영선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.39-46
    • /
    • 1990
  • This paper was analized the thermal conductivity of polystylene (TENSAR- GEOGRID) embeding into the subbase through frost penetration depth, frost heave, change of bearing capacity, and soil moisture movement due to freezing, thawing and icing actions, and their results were as follows : 1.The change of temperature into the sub-base was much increased by the Tensar-Geogrid insertion, and the frost penetration and frost heave were decreased as the thinner of the insulation thickness but the thawing velocity of melting period was appeared to be faster in case of non-insulated. 2.The frost heave had a close relationship with the thickness of insulations which was reasonably included anti-frost effects. 3.The moisture content during the freezing period of upper layer of the insulation insertion was increased by 15 per cent but it was returned to initial state of the thawing period, and at the down layer temporarily increased by 10 per cent and returned to the original state at once. 4.The insulation was acted as a function of distribution of surcharge, and the settlement of the sub-base was about 1.5 mm under 15 tonnage of load and which was included within the allowable limits. 5.The sliding resistance due to the icing which was induced by the insulation insertion into the sub-base was appeared as more 40 per cent than noninsulation area, so that the insulations should be restricted on the place such as mountains, curved and cross area which were required the braking power under the traffics.

  • PDF

Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger (지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석)

  • Gil, Hu-Jeong;Lee, Kang-Ja;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation (수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Kim, Ju-Young;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Nitrate Removal of a Cattail Wetland Cell Purifying Effluent from a Secondary-Level Treatment Plant During Its Initial Operating Stage (2차처리장 방류수 정화 부들습지셀의 초기운영단계 질산성질소 제거)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.228-233
    • /
    • 2004
  • Nitrate removal was examined from May to October 2003 of a surface flow treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and a distribution pond The system was established on rice paddy near the Kohung Estuarine Lake located in the southern part of the Korean Peninsula. Effluent from a secondary-level night soil treatment plant was funneled into the system. The investigated cell, 87 m in length and 14 m in width, was created in April 2003. An open water was designed at its center, which was equivalent to 10 percent of its total area. Cattails (Typha angustifolia) were transplanted from natural wetlands into the cell and their stems were cut at about 40cm height from their bottom ends. Average $25.0\;m^3/day$ of effluent from the treatment plant was funneled into the cell by gravity flow and average $24.1\;m^3/day$ of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. Average height of the cattail stems was 42.5 cm in May 2M3 and 117.7 cm in September 2003. The number of stems averaged $9.5\;stems/m^2$ in May 2003 and $16.4\;stems/m^2$ in September 2003. The growth of cattails was good. Temperature of influent and effluent averaged 25.9 and $26.7^{\circ}C$, respectively. $NO_3$-N loading rate of influent and effluent averaged 176.67 and $88.09\;mg/m^2\;day$, respectively. Removal of rf03-N averaged $89.58\;mg/m^2\;day$ and its removal rate by mass was about 50%. Considering its initial operating stage in which cattail rhizomes and litter layer on the bottom were not Idly established, the $NO_3$-N removal rate of the cell was rather good.

A Study on the Comparison of Spatial Evapotranspiration between SEBAL and SWAT model results (SEBAL 모형과 SWAT 모형의 공간 증발산량 산정결과 비교 연구)

  • LEE, Yong-Gwan;JUNG, Chung-Gil;AHN, So-Ra;KIM, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.470-470
    • /
    • 2015
  • 본 연구의 목적은 위성영상 기반의 SEBAL(Surface Energy Balance Algorithm for Land) 모형과 SWAT(Soil and Water Assessment Tool) 수문모형을 용담댐 유역($922.3km^2$)에 적용하여 증발산량을 산정하고 모형 간 공간 증발산량의 비교를 통해 각 모형의 적용성을 평가하는데 있다. 이를 위해 SEBAL모형의 입력자료로 Terra MODIS(Moderate Resolution Imaging Spectrometer) Product 중 Normalized Distribution Vegetation Index(NDVI), Albedo 영상을 2012년부터 2013년까지 월단위로 구축하고, 일단위의 Land Surface Temperature(LST) 영상을 구축하였다. 지형자료로는 Digital Elevation Model(DEM)과 Land use를 구축하였으며 SEBAL 모형의 구동을 위한 위성영상 및 지형자료는 500 m의 공간해상도로 재구축하였다. SWAT 모형의 모의를 위해 기상 및 유량 자료를 2000년부터 2013년까지 일단위로 구축하였고, DEM, Land use, 토양도의 지형자료를 30 m의 공간해상도로 구축하였다. SWAT 모형의 유출 검보정 후 수위관측소 지점에서 평균 $R^2$를 산정한 결과 도치(0.80), 동향(0.72), 석정(0.64), 주천(0.80), 천천(0.80), 용담댐(0.72)로 높은 상관성을 나타냈으며, 유출 검보정 후 SWAT 모형의 증발산량 모의 결과를 바탕으로 SEBAL 모형과의 공간 증발산량을 비교하였다. 두 모형의 증발산량은 SEBAL 모형의 경우 지형에 따라 SWAT 모형은 토양 특성에 따라 분포하는 경향이 다르게 나타났다. SEBAL 모형은 주로 저지대에서 증발산량이 높게 산정되며 고지대로 갈수록 감소하여 증발산량이 지형의 고저차에 따라 분포하는 모습을 보였다. SWAT 모형은 토양 특성에 따라 증발산량이 분포하며 유역 내에서 뚜렷한 차이를 나타내지는 않았다. 월별 총 증발산량은 SWAT 모형의 경우 7~8월에 약 90 mm/mon로 가장 높게 나타나고 1~2월은 0 mm/mon로 계절별 변화폭이 컸으나, SEBAL 모형의 경우 5~6월에 증발산량이 약 60 mm/mon로 가장 높게 나타났고 계절별 변화 폭이 SWAT 모형에 비해 적은 모습을 보였다. 이는 위성영상을 기반으로 하는 SEBAL 모형의 특성상 장마 기간에 해당하는 7~8월은 구름으로 인해 일사량이 적게 계산되고, 그 결과 5~6월에 비해 증발산량이 작게 산정되는 것으로 판단된다.

  • PDF

Distribution of Organic Matter and Nitrogenous Oxygen Demand in Effluent of Sewage and Wastewater Treatment Plants (하·폐수처리시설 방류수내 유기물질 및 NOD 분포 특성)

  • Kim, Ho-Sub;Kim, Seok-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.20-31
    • /
    • 2021
  • In this study, an analysis of the characteristics of organic matter and nitrogenous oxygen demand (NOD) of 17 sewage effluent and wastewater treatments was conducted. High CODMn and carbonaceous biological oxygen demand (CBOD) concentrations were observed in the livestock treatment plants (LTP), wastewater treatment plants(WTP), and night soil treatment plants (NTP), but the highest NOD concentration and contribution rates of NOD to BOD5 were found in sewage treatment plants (STP). There was no significant difference in the CBOD/CODMn ratio for each of the six pollution source groups, but the LTPs, WTPs, and NTPs all showed relatively high CODMn concentrations in their effluent samples, indicating that they are facilities which discharge large amounts of refractory organic matter. The seasonal change of NOD in all facilities' effluent was found to be larger than the seasonal change of CBOD, and data results also revealed an elevation of NOD and NH3-N concentration from December to February, when the water temperature was low. There was no significant difference in NH3-N concentration in relation to pollution source group (p=0.08, one-way ANOVA), but the STP, which had a high NOD contribution rate to BOD5 of 48%, showed a high correlation between BOD5 and NOD (r2=0.95, p<0.0001). These results suggest that the effect of NOD on BOD5 is an important factor to be considered when analyzing STP effluent.

Identification of the Transmissive Fractures in the Vicinity of waterway Tunnel (도수로터널 주변 지역의 지하수 유동성 단열 규명)

  • 이병대;이인호;추창오;함세영;성익환;황세호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.33-44
    • /
    • 2002
  • A field technique for assessing the transmissive fractures in an aquifer was applied to a fractured rock formation in Youngchun area Korea. Geological mapping and detailed acoustic borehole teleview(BHTV) logging were performed to obtain information about the fractures. The study area consists predominantly of two types of fractures. The fracture sets of low angle partings such as bedding and sheeting plains have strike N70-80$^{\circ}$W, 25$^{\circ}$-30$^{\circ}$SW and N3S$^{\circ}$W, 12$^{\circ}$NE, respectively. In areas of high fractures, on the other hand, the major fracture sets show strike N80$^{\circ}$W and dip 70$^{\circ}$-85$^{\circ}$SW, N10$^{\circ}$E.85$^{\circ}$SE in sedimentry rocks, N40-50$^{\circ}$E.85$^{\circ}$SE/85$^{\circ}$NE, N70$^{\circ}$E.80$^{\circ}$SE, and N7$^{\circ}$-75$^{\circ}$W.80$^{\circ}$SW in granites and volcanic rocks. Injection tests have been performed to identify discrete production zones and quantify the vertical distribution of hydraulic conductivity. The calculated hydraulic conductivities range from 3.363E-10 to 2.731E-6, showing that the difference between maximum and minimum value is four order of magnitude. Dominant section in hydraulic conductivity is extensively fractured. Geophysical logging was carried out to clarify characterization of the distribution of fracture zones. Transmissive fractures were evaluated through the comparison of the results obtained by each method. The temperature logs appeared to be a good indicator that can distinguish a high transmissive fractures from a common fractures in hydraulic conductivity. In numerous cases, evidence of fluid movement was amplified in the temperature gradient log. The fracture sets of N70-80$^{\circ}$W.60-85$^{\circ}$NE/SW N75-80$^{\circ}$W.25-30$^{\circ}$SW, N50-64$^{\circ}$W.60-85$^{\circ}$NE, N35-45$^{\circ}$E.65-75$^{\circ}$SE, and N65-72$^{\circ}$E.80$^{\circ}$SE/60$^{\circ}$NW were idenfied as a distinct transmissive fractures through the results of each tests.

Survey on distribution and vegetation environment of Tricholoma matsutake in Kyonggi province, Korea (경기도지역 송이버섯 분포 및 식생환경조사)

  • Ha, Tai-Moon;Kim, Young-Ho;Chi, Jeong-Hyun;Ju, Young-Cheuol;Kim, Hee-Dong;Sung, Jae-Mo
    • Journal of Mushroom
    • /
    • v.2 no.4
    • /
    • pp.175-183
    • /
    • 2004
  • We carried out survey of a pine mushroom picking district and its vegetation environment for increase and maintainment of its production in Kyonggi province. The district which we could pick up pine mushroom among the nineteen surveyed district were sixteen such as Geoleun ri Gangcheon myeon Yeoju gun Kyonggi do, etc. and total yields were 470~600 kg in Kyonggi province. The temperature of atmosphere and earth in Yeoju and Bonghwa were droped to $19^{\circ}C$ at 5~7th september and maintained from $12^{\circ}C{\sim}18^{\circ}C$ during the a pine mushroom picking period. The density of a pine tree per $100m^2$ was 5.1~27.1 trees, the years of it was 15~50years old and height was 4~11 meter. The pine tree in a pine mushroom picking district was competed with oak trees, azaleas, lacquers, etc. The depth of organic materials accumulated on the pine mushroom mycelium layer was 4.5 cm in Yeoju. The soil texture of a pine mushroom picking district was almost sandy, soil pH was 4.3~5.1 and organic material content was 3.91~8.28%.

  • PDF

Diversity and Occurrence Frequency of Ectomycorrhizal Fruiting Bodies by Planting Sites (식재지별 외생균근성 버섯의 다양성 및 발생 빈도 비교)

  • Chung, Jin-Chul;Oh, Kwang-In;Jang, Seog-Ki;Jang, Kyu-Kwan
    • The Korean Journal of Mycology
    • /
    • v.32 no.2
    • /
    • pp.71-78
    • /
    • 2004
  • This study was conducted to investigate the diversity and occurrence frequency of ectomycorrhizal fruit bodies by planting sites from June 2000 to October 2001. A total of 3 classes 3 subclasses 8 orders 22 families 41 genera and 72 species (including two varieties) including saprophytic and ectomycorrhizal fungi was investigated. The mushrooms are classified into 9 families 21 genera and 48 species in Agaricales, 5 families 11 genera and 13 species in Aphllophorales, 3 families 3 genera and 4 species in Heterobasidiomycetes and 5 families 6 genus and 7 species in Gasteromycetdae. A total of 7 families 11 genera 30 species (2,451 ea.) of ectomycorrhizal mushroom was investigated. The occurrence frequency of mushrooms was 1,225, 179 and 130 times for Laccaria vinaceoavellanea, Amanita longistriata and Laccaria amethystea, respectively. The mushroom occurrence of ectomycorrhizal fungi was closely related to climatic conditions such as high air temperature, relative humidity and lots of rainfall from July to August. Diversity and distribution of ectomycorrhizal fungi by plots were very different because of variable local environments and different host plants in experimental plots. Laccaria vinaceoavellanea has showed very low host range of plant specificity because of mushroom occurrence in only Quercus sp. and Amanita longistriata, Russula bella and Inocybe sp. have showed wide host range of plant specificity because of mushroom occurrence in coniferous and broadleaved trees. The environment which has a favorable influence of mushroom occurrence was soil pH, organic matter and T/N ratio of soil enviromental and humidity of climatic environment.

The Comparison of Community Characteristics of Ground-dwelling Invertebrates According Agroecosystem Types in the Eastern Region of the Korean Peninsula (한반도 동부 농업생태계에 따른 지표배회성 무척추동물의 군집 특성 비교)

  • Ahn, Chi-Hyun;Oh, Young-Ju;Ock, Suk-Mi;Lee, Wook-Jae;Sohn, Soo-In;Kim, Myung-Hyun;Na, Young-Eun;Kim, Chang-Seok
    • Korean journal of applied entomology
    • /
    • v.56 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • To compare the features of ground-dwelling invertebrates according agroecosystems, we selected paddy fields, dry fields, orchards in the Eastern region of Korea. The surveys were performed by using pit-fall traps twice per year from 2013 to 2015. Total 6,420 individuals of 172 species belonging to 13 orders, 58 families were investigated in the Eastern region, the species of Hymenoptera (38.26%), Orthoptera (16.28%) accounted large portion of the communities. In the geographical observation, invertebrates were caught was 2,983 individuals in Gyeongsangnam-do, the diversity index of Gyeongsangbuk-do community was higher than of the others and abundance and species richness of paddy field were higher than from dry field or orchard. To understand the relation between taxonomic groups and environmental factors, we carried out the canonical correspondence analysis and hierarchical clustering. As a result, Homoptera, Blattaria, Isoptera, and Coleoptera were positively related to soil pH, soil temperature, and moisture contents, and negatively related to the others. Invertebrate community also were patterned dependently by type of ecosystems. This results were shown that distribution of invertebrates is a few influenced the relationship of the space habituated invertebrates and environmental factors.