• Title/Summary/Keyword: soil gas monitoring

Search Result 59, Processing Time 0.032 seconds

Sn$O_2$ Ceramic Gas Sensor for VOC Contaminated Soil Gas Monitoring (VOC 함유 토양가스 모니터링을 위한 Sn$O_2$ 세라믹 가스센서의 반응특성 연구)

  • 최관영;조현정;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.125-128
    • /
    • 2000
  • Recently, development of advanced soil monitoring technology has became essential for effective site remediation. Soil gas evaluation is simple and powerful technology which can reduce the environmental impact during the survey of VOC contaminated area. In this research, the feasibility test of SnO$_2$ceramic gas sensor is conducted to improve soil gas measurement technology. As a result, it is successfully proved that this gas sensor has an possibility for soil gas monitoring.

  • PDF

Development of In-Situ Soil Gas Monitoring Well for Managing the Bioventing Performance (생물학적 통풍법 공정관리를 위한 원위치 토양가스 관측정 개발)

  • Yu, Chan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.1
    • /
    • pp.67-76
    • /
    • 2007
  • Bioventing is commonly used for petroleum hydrocarbon (PHC) spills. This process provides better subsurface oxygenation, thus stimulating degradation by indigenous microorganisms. Therefore soil vapor monitoring points (VMPs) are extremely important in determining the potential effectiveness of bioventing and in long-term monitoring of bioventing progress. In this study in-situ soil gas monitoring well (GMW) was developed and presented the pilot test results which recover the contaminated site by bioventing method. The result of application was successful and it was expected that GMW developed could be applied to the evaluation procedure of bioventing effectiveness and long-term remediation potential.

Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

세라믹 가스센서를 이용한 토양증기추출공정의 배출가스 모니터링 기법 연구

  • 양지원;조현정;이재영;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.250-252
    • /
    • 2002
  • The goals of environmental monitoring are to locate and quantify the significant contamination, estimate the fate and transport, estimate the potential exposure and risks to humans and the environment, and track the performance of various remedial technologies. In this study, ceramic gas sensor system is proposed to enhance the effectiveness of soil vapor extraction (SVE) process by monitoring the effluent gas. SVE is a technique that is widely used to remediate unsaturated soils contaminated with volatile organic contaminants. The sensor response for benzene, toluene, and xylene, the representative effluent gas compositions of SVE process, was evaluated using the proposed sensor system. As a result, it was verified that the response of sensor was increased or decreased very sensitively according to the change of the effluent gas concentration. Besides, the sensor could detect the difference over a wide range of concentration and it was more sensitive in order of xylene, toluene, and benzene. It is expected that this VOC analysis method results in field monitoring costs saying and appropriate immediate action for process control. More detailed experiments are being conducted in our research group.

  • PDF

A case study of remote wireless monitoring system for stray current due to subway system (지하철 누설전류 무선 원격 감시시스템 적용 사례)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

Soil CO2 Monitoring Around Wells Discharging Methane (메탄 유출 관정 주변의 토양 CO2 모니터링)

  • Chae, Gitak;Kim, Chan Yeong;Ju, Gahyeun;Park, Kwon Gyu;Roh, Yul;Lee, Changhyun;Yum, Byoung-Woo;Kim, Gi-Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.407-419
    • /
    • 2022
  • Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO213CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.

Drivability Monitoring of Large Diameter Underwater Steel Pipe Pile Using Pile Driving Analyzer. (수중 대구경강관말뚝의 항타관입성 모니터링을 위한 PDA 적용 사례)

  • Kim, Dae-Hak;Park, Min-Chul;Kang, Hyung-Sun;Lee, Won-Je
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.11-19
    • /
    • 2004
  • When pile foundation constructed by driving method, it is desirable to perform monitoring and estimation of pile drivability and bearing capacity using some suitable tools. Dynamic Pile Monitoring yields information regarding the hammer, driving system, and pile and soil behaviour that can be used to confirm the assumptions of wave equation analysis. Dynamic Pile Monitoring is performed with the Pile Driving Analyser. The Pile Driving Analyser (PDA) uses wave propagation theory to compute numerous variables that fully describe the condition of the hammer-pile-soil system in real time, following each hammer impact. This approach allows immediate field verification of hammer performance, driving efficiency, and an estimate of pile capacity. The PDA has been used widely as a most effective control method of pile installations. A set of PDA test was performed at the site of Donghea-1 Gas Platform Jacket which is located east of Ulsan. The drilling core sediments of location of jacket subsoil are composed of mud and sand, silt. In this case study, the results of PDA test which was applied to measurement and estimation of large diameter open ended steel pipe pile driven by underwater hydraulic hammer, MHU-800S, at the marine sediments were summarized.

  • PDF

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.