• Title/Summary/Keyword: soil column

Search Result 836, Processing Time 0.035 seconds

Desalinization of marine soil by the application of straw and lime (개흙의 제염에 미치는 볏짚, 석회의 병용효과)

  • Oh, Wang-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 1991
  • A laboratory column experiment was conducted to learn the desalinization effect of rice straw, fresh or predecayed in limed marine soil, compared with gypsum. One third of Ca equivalent to indigenous Na plus Mg of the soil was applied to the top 10g out of 80g of total column soil, mixing one half of it to the top soil and the rest spreading on the surface. 1. Pre-decaying of rice straw in limed marine soil promoted the permeability of column soil. but showed a less effectiveness in desalinization of sodium than lime alone or lime plus fresh rice straw treatemenents. 2. Gypsum and calcium carbonate treatments without rice straw fixed Mg in the limed top soil and washed it down disolving more from the layer immediatly be low the treated top soil But the treatment of calcium carbonate and rice straw both together washed out Mg more from lower layers than the upper's, showing only physical desalinization. 3. The desalinization of Na was also severe in the layer immediately below the $CaSO_4$ treated top soil, leauing more Na ilo the top soil, which seemed to be attributed to the peptisation of the top soil and retard peptisation of desalinization when washed the soil applying not enough amount or non of gypsum.

  • PDF

Leaching Behavior of the Residues of Carbofuran, Bentazon, and TCAB in Soil (Carbofuran, Bentazon 및 TCAB 잔류물의 토양중 용탈)

  • Lee, Jae-Koo;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.1
    • /
    • pp.9-17
    • /
    • 1993
  • The leaching behavior of $^{14}C-carbofuran$, $^{14}C-bentazon$, and $^{14}C-3,3,4,4'-tetrachloroazobenzene(TCAB)$ in the forms of freshly treated, 3-month-aged, and 6-month-aged residues, respectively, was investigated in a loamy soil column system. The degradation and mobility of pesticides in soil and the possibility of the contamination of groundwater were followed by this approach: The ambient temperature of $15{\pm}2^{\circ}C$, irrigation by the constant-head method on soil columns, and leaching with 1332 ml of simulated precipitation during 90 days. While the fresh residues of $^{14}C-carbofuran$ and $^{14}C-bentazon$ were very mobile, the aged ones were remarkably reduced in their mobility. Fresh and aged residues of $^{14}C-TCAB$ were very immobile, instead. 3-Keto carbofuran phenol(2,3-dihydro-2,2-dimethyl-3-oxo-7-benzofuranol) was the major degradation product present in the leachate from the soil column containing freshly treated $^{14}C-carbofuran$, while no metabolites could be detected in the leachates from the columns containing $^{14}C-bentazon$ or $^{14}C-TCAB$.

  • PDF

Theoretical Modeling of the Resonant Column Testing with the Viscosity of a Specimen Considered (점성을 고려한 공진주 실험의 이론적 모델링)

  • 조성호;황선근;권병성;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.145-153
    • /
    • 2003
  • The resonant column testing determines the shear modulus and material damping factor dependent on the shear strain magnitude, based on the wave-propagation theory. The determination of the dynamic soil properties requires the theoretical formulation of the dynamic behavior of the resonant column testing system. One of the theoretical formulations is the use of the wave equation for the soil specimen in the resonant column testing device. Wood, Richart and Hall derived the wave equation by assuming the linear elastic soil, and didn't take the material damping into consideration. Hardin incorporated the viscoelastic damping of soil in the wave equation, but he had to assume the material damping factor for the determination of the shear modulus. For the better theoretical formulation of the resonant column testing, this study derived a new wave equation to include the viscosity of soil, and proposed an approach for the solution. Also, in this study, the equation of motion for the testing system, which is another approach of the theoretical formulation of the resonant column testing, was also derived. The equation of motion leads to the better understanding of the resonant column testing, which includes the dynamic magnification factor and the phase angle of the response. For the verification of the proposed equation of motion for the resonant column testing, the finite element analysis was performed for the resonant column testing. The comparison of the dynamic magnification factors and the phase angles far the system response were performed.

Capillary Characteristics of Water and Cations in Multi-layered Reclaimed Soil with Macroporous Subsurface Layer Utilizing Coal Bottom Ash

  • Ryu, Jin-Hee;Chung, Doug-Young;Ha, Sang-Keon;Lee, Sang-Bok;Kim, Si-Ju;Kim, Min-Tae;Park, Ki-Do;Kang, Hang-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.406-411
    • /
    • 2014
  • Serious problems in reclaimed land agriculture are high soil salinity and poor vertical drainage, so desalinization in these soils is very difficult. Also, although desalinization is accomplished in reclaimed top soils, before long, soils are resalinized according to capillary rise of salts from the subsurface soils. To resolve these problems, multi-layered soil columns with subsurface layer of macroporous medium utilizing coal bottom ash (CBA) were constructed and the effects of blocked resalinization of these soils were investigated. In this experiment soil samples were collected from Munpo series (coarse-loamy, nonacid, mixed, mesic, typic Fluvaquents). The soil texture was silt loam and the EC was $33.9dS\;m^{-1}$. As for groundwater seawater was used and groundwater level of 1 cm from the bottom was maintained. The overall rate of capillary rise was $2.38cm\;hr^{-1}$ in soil 60 cm column, $0.25cm\;hr^{-1}$ in topsoil (30 cm) + CBA (5 cm) + subsurface soil (10 cm) column and $0.08cm\;hr^{-1}$ in topsoil (30 cm) + CBA (10 cm) + subsurface soil (10 cm) column. In multi-layered soil columns with CBA 20, 30 cm layer, wetting front due to capillary rise could not be seen in top soil layer. After 70 days capillary rise experiment water soluble Na+ accumulated in top soil of soil columns with CBA 20, 30 cm was diminished by 92.8, 96.5% respectively in comparison with Na+ accumulated in top soil of soil 60 cm column because CBA layer cut off capillary rise of salts from the subsurface soil. From these results we could conclude that the macroporous layer utilizing CBA placed at subsurface layer cut off capillary rise of solutes from subsurface soil, resulting in lowered level of salinity in top soil and this method can be more effective in newly reclaimed saline soil.

토양내 탄화수소계 화합물의 농도측정 기법에 대한 TDR(Time Domain Reflectometry)적용 가능성 연구

  • 박민수;김동주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.201-205
    • /
    • 1998
  • Leakage of hydrocarbon compound from underground storage tank has been a significant issue to the hazard of environmental contaminants. It is therefore necessary to develop the measurement technique of hydrocarbon compound concentration. In this study, the possibility of TDR application to measure concentration of hydrocarbon compound, especially diesel, in a sandy soil was investigated. Experiments were conducted in two different conditions. The first one was to measure the resistances of the soil columns packed according to the various ratios of tab water and diesel content in the total voids. The other was to measure the resistance of the soil under the flow condition where diesel oil was allowed to infiltrate into the KCl-saturated soil column. The experimental results showed that there exists a significant relationship between oil% and TDR-measured resistance. This suggests that TDR can be an effective device to measure the concentration of hydrocarbon compound in a soil.

  • PDF

Increase of Electrokinetic Soil Remediation Efficiency using Ethanoic Buffer (초산완충액에 의한 동전기적 토양복원 효과 증진 연구)

  • Kim, Gye-Nam;Oh, Won-Zin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2007-2016
    • /
    • 2000
  • After kaolin clay was compulsorily contaminated with $Sr^{2+}$ ion. the remediation characteristics by electrokinetic method were analyzed. In the first experiment. NaCl solution was used as an electrolyte to raise the electric field strength. After remediation for 0.8 days. the pH of the cathode side of the soil column was elevated from 4.0 to 11.7. and thereby precipitation $Sr(OH)_2$, started to be formed in the side. Therefore. efficiency of soil remediation was reduced significantly and the 32% of total $Sr^{2+}$ ion in the column was decontaminated in 6.7 days. In the second experiment. ethanoic buffer was injected in the soil column and $CH_3COOH$ was continuously inputted in cathode reservoir to restrain the pH elevation. The pH of the cathode side of the soil column was only ascended from 4.0 to 6.0 in 3.8 days and $Sr(OH)_2$ was not formed. The 21% of total $Sr^{2+}$ in the soil column was decontaminated in 0.6 days. and the 33% of total $Sr^{2+}$ in 0.9 days. and the 84% of total $Sr^{2+}$ in 1.6 days. and the 92% of total $Sr^{2+}$ in 2.5 days. and the 97% of total $Sr^{2+}$ in 3.8 days. Meanwhile. the residual concentrations in the column calculated by the developed model were similar to those by experiment.

  • PDF

Analysis of rainfall infiltration characteristics for unsaturated soils using a column test equipment (모형실험장치를 이용한 불포화토의 강우 침투특성 분석)

  • Park, Kyu-Bo;Chae, Byung-Gon;Kim, Kyeong-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.736-742
    • /
    • 2010
  • This study was conducted to characterize on the relationships of rainfall intensity and infiltration rate of rainfall dependent on unit weight change in the gneissic weathered soil by a column test equipment. In this study, volumetric water content and pore water pressure were measured using TDR sensors and tensiometers at regular time intervals. Rainfall conditions including continuous rainfall and repeated rainfall were selected in order to know the effect of antecedent rainfall. In the condition of rainfall intensity 20mm/h and the unit weights of soil as $1.35g/cm^3$, $1.55g/cm^3$ and $1.61g/cm^3$, average rainfall infiltration rate was $2.814{\times}10^{-3}cm/sec$, $1.969{\times}10^{-3}cm/sec$ and $1.252{\times}10^{-3}cm/sec$ respectively. The higher rainfall intensity and lower unit weight of soil, the faster average infiltration rate. Overflow in the column was happened except rainfall condition of rainfall intensity 20mm and soil unit weight $1.35g/cm^3$. Increasing the soil unit weight, overflowed water was increased and occurrence time was faster.

  • PDF

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Assessing pollutants' migration through saturated soil column

  • Smita Bhushan Patil;Hemant Sharad Chore;Vishwas Abhimanyu Sawant
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 2023
  • In the developing country like India, groundwater is the main sources for household, irrigation and industrial use. Its contamination poses hydro-geological and environmental concern. The hazardous waste sites such as landfills can lead to contamination of ground water. The contaminants existing at such sites can eventually find ingress down through the soil and into the groundwater in case of leakage. It is necessary to understand the process of migration of pollutants through sub-surface porous medium for avoiding health risks. On this backdrop, the present paper investigates the behavior of pollutants' migration through porous media. The laboratory experiments were carried out on a soil-column model that represents porous media. Two different types of soils (standard sand and red soil) were considered as the media. Further, two different solutes, i.e., non-reactive and reactive, were used. The experimental results are simulated through numerical modeling. The percentage variation in the experimental and numerical results is found to be in the range of 0.75- 11.23 % and 0.84 - 1.26% in case of standard sand and red soil, respectively. While a close agreement is observed in most of the breakthrough curves obtained experimentally and numerically, good agreement is seen in either result in one case.

Performance Evaluation of a Double Layer Biofilter System to Control Urban Road Runoff (I) - System Design - (이중층 토양 여과시설을 이용한 도로 강우 유출수 처리성능 평가 (I) - 시설 설계인자 결정을 중심으로 -)

  • Cho, Kang Woo;Kim, Tae Gyun;Lee, Byung Ha;Lee, Seul Bi;Song, Kyung Guen;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.599-608
    • /
    • 2009
  • This manuscript covers the results of field investigation and lab-scale experiments to design a double-layered biofilter system to control urban storm runoff. The biofilter system consisted of a coarse soil layer (CSL) for filtration and fine soil layer (FSL) for adsorption and biological degradation. The variations of flow rate and water quality of runoff from a local expressway were monitored for seven storm events. Laboratory column experiments were performed using seven kinds of soil and mulch to maximize pollutants removal. The site mean concentration (SMC) of storm runoff from the drainage area (runoff coefficient: 0.92) was measured to be 203 mg/L for SS, 307 mg/L for $TCOD_{Cr}$, 12.3 mg/L for TN, 7.3 mg/L for ${NH_4}^+-N$, and 0.79 mg/L for TP, respectively. This study employed a new design concept, to cover the maximum rainfall intensity with one month recurrence interval. Effective storms for last ten years (1998-2007) in seoul suggested the design rainfull intensity to be 8.8 mm/hr Single layer soil column showed the maximum removal rate of pollutants load when the uniformity coefficient of CSL was 1.58 and the silt/clay contents of FSL was virtually 7%. The removal efficiency during operation of double layer soil column was 98% for SS and turbidity, 75% for TCODCr, 56% for ${NH_4}^+-N$, 87% for TP, and 73-91% for heavy metals. The hydraulic conductivity of the soil column, 0.023 cm/sec, suggested that the surface area of the biofilter system should be about 1% of the drainage area to treat the rainfall intensity of one month recurrence interval.