• 제목/요약/키워드: software measurement

Search Result 1,442, Processing Time 0.029 seconds

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

Evaluation of the dimensional change of 3D-printed complete denture after post-curing (후경화에 따른 3차원 프린팅 의치의 체적변화)

  • Suyeon, Lee;Younghun, Kwak;Eunchul, Park;Heejung, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.233-241
    • /
    • 2022
  • Purpose: The purpose of this study was to assess the dimensional change of 3D-printed dentures after post-curing. Materials and Methods: The upper and lower dentures were designed in Exocad DentalCAD software and exported as STL files. The upper and lower dentures were printed from 10 STL files using a DLP-type dental 3D printer. The printed upper and lower dentures were cleaned, and a scan file was created using a model scanner before and after post-curing. The dimensional change was evaluated by superimposing the scanned denture files before and after post-curing and measuring the distance between measurement points on the denture. SPSS was used for statistics, and the level of significance was 5%. Results: The maxillary denture reduced in size during post-curing, with the most notable color change occurring in the posterior palatal region. The reduction in anteroposterior maxillary denture length (A-D, A-E, A-F), as well as the distance between the first molars on both sides (B-C), was statistically significant. After post-curing, the mandibular denture showed more noticeable color change in the posteriorly buccal and lingual region. The decrease of length on the posterior (A-M, A-D, A-E, A-L, A-H, A-I, H-I) and lingual (J-K, L-M) sides of the denture were statistically significant. Conclusion: There was significant dimensional change in both the length and width of the 3D-printed maxillary and mandibular dentures after post-curing in this experiment. Consequently, it is seemed necessary to develop post-curing techniques and materials that reduce such denture deformation.

Radioactive Concentrations in Chemical Fertilizers

  • Gwang-Ho Kim;Jae-Hwan Cho
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.195-203
    • /
    • 2022
  • Background: The aim of the present study was to determine radioactive concentrations in fertilizers known to contain essential nutrients. Results of this study could be used as basic data to monitor the impact of chemical fertilizers on the environment and public health. Nitrogen fertilizers, calcium fertilizers, sulfur fertilizers, phosphate acid fertilizers, and potassium chloride fertilizers were used in this study. Materials and Methods: Five chemical fertilizers were pulverized, placed in polyethylene containers, and weighed. The time to measure each specimen was set to be 3,600 seconds for a scintillator-based gamma-ray spectroscopy system. Concentration of gamma radionuclide was analyzed based on obtained spectra. At the end of the measurement, the spectrum file was stored and used to calculate radioactive concentrations using a gamma-ray spectrometer software. Results and Discussion: In the nitrogen fertilizer, 3.49 ± 5.71 Bq/kg of 137Cs, 34.43 ± 7.61 Bq/kg of 134Cs, and 569.16 ± 91.15 of 40K were detected whereas 131I was not detected. In the calcium fertilizer, 5.74 ± 4.40 Bq/kg of 137Cs (the highest concentration among all fertilizers), 22.37 ± 5.39 Bq/kg of 134Cs, and 433.67 ± 64.24 Bq/kg of 40K were detected whereas 131I was not detected. In the sulfur fertilizer, 347.31 ± 55.73 Bq/kg of 40K, 19.42 ± 4.53 Bq/kg of 134Cs, 2.21 ± 3.49 of 137Cs, and 0.04 ± 0.22 Bq/Kg of 131I were detected. In the phosphoric acid fertilizer, 70,007.34 ± 844.18 Bq/kg of 40K (the highest concentration among all fertilizers) and 46.07 ± 70.40 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. In the potassium chloride fertilizer, 12,827.92 ± 1542.19 Bq/kg of 40K was and 94.76 ± 128.79 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. The present study examined inorganic fertilizers produced by a single manufacturer. There might be different results according to the country and area from which fertilizers are imported. Further studies about inorganic fertilizers in more detail are needed to create measures to reduce 40K. Conclusion: Measures are needed to reduce radiation exposure to 40K contained in fertilizers including phosphoric acid and potassium chloride fertilizers.

Examination of Aggregate Quality Using Image Processing Based on Deep-Learning (딥러닝 기반 영상처리를 이용한 골재 품질 검사)

  • Kim, Seong Kyu;Choi, Woo Bin;Lee, Jong Se;Lee, Won Gok;Choi, Gun Oh;Bae, You Suk
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.6
    • /
    • pp.255-266
    • /
    • 2022
  • The quality control of coarse aggregate among aggregates, which are the main ingredients of concrete, is currently carried out by SPC(Statistical Process Control) method through sampling. We construct a smart factory for manufacturing innovation by changing the quality control of coarse aggregates to inspect the coarse aggregates based on this image by acquired images through the camera instead of the current sieve analysis. First, obtained images were preprocessed, and HED(Hollistically-nested Edge Detection) which is the filter learned by deep learning segment each object. After analyzing each aggregate by image processing the segmentation result, fineness modulus and the aggregate shape rate are determined by analyzing result. The quality of aggregate obtained through the video was examined by calculate fineness modulus and aggregate shape rate and the accuracy of the algorithm was more than 90% accurate compared to that of aggregates through the sieve analysis. Furthermore, the aggregate shape rate could not be examined by conventional methods, but the content of this paper also allowed the measurement of the aggregate shape rate. For the aggregate shape rate, it was verified with the length of models, which showed a difference of ±4.5%. In the case of measuring the length of the aggregate, the algorithm result and actual length of the aggregate showed a ±6% difference. Analyzing the actual three-dimensional data in a two-dimensional video made a difference from the actual data, which requires further research.

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

A Study on Open Source Version and License Detection Tool (오픈소스 버전 및 라이선스 탐지 도구에 관한 연구)

  • Ki-Hwan Kim;Seong-Cheol Yoon;Su-Hyun Kim;Im-Yeong Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.299-310
    • /
    • 2024
  • Software is expensive, labor-intensive, and time-consuming to develop. To solve this problem, many organizations turn to publicly available open source, but they often do so without knowing exactly what they're getting into. Older versions of open source have various security vulnerabilities, and even when newer versions are released, many users are still using them, exposing themselves to security threats. Additionally, compliance with licenses is essential when using open source, but many users overlook this, leading to copyright issues. To solve this problem, you need a tool that analyzes open source versions, vulnerabilities, and license information. Traditional Blackduck provide a wealth of open source information when you request the source code, but it's a heavy lift to build the environment. In addition, Fossology extracts the licenses of open source, but does not provide detailed information such as versions because it does not have its own database. To solve these problems, this paper proposes a version and license detection tool that identifies the open source of a user's source code by measuring the source code similarity, and then detects the version and license. The proposed method improves the accuracy of similarity over existing source code similarity measurement programs such as MOSS, and provides users with information about licenses, versions, and vulnerabilities by analyzing each file in the corresponding open source in a web-based lightweight platform environment. This solves capacity issues such as BlackDuck and the lack of open source details such as Fossology.

A Comparative Study on the Effective Deep Learning for Fingerprint Recognition with Scar and Wrinkle (상처와 주름이 있는 지문 판별에 효율적인 심층 학습 비교연구)

  • Kim, JunSeob;Rim, BeanBonyka;Sung, Nak-Jun;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.17-23
    • /
    • 2020
  • Biometric information indicating measurement items related to human characteristics has attracted great attention as security technology with high reliability since there is no fear of theft or loss. Among these biometric information, fingerprints are mainly used in fields such as identity verification and identification. If there is a problem such as a wound, wrinkle, or moisture that is difficult to authenticate to the fingerprint image when identifying the identity, the fingerprint expert can identify the problem with the fingerprint directly through the preprocessing step, and apply the image processing algorithm appropriate to the problem. Solve the problem. In this case, by implementing artificial intelligence software that distinguishes fingerprint images with cuts and wrinkles on the fingerprint, it is easy to check whether there are cuts or wrinkles, and by selecting an appropriate algorithm, the fingerprint image can be easily improved. In this study, we developed a total of 17,080 fingerprint databases by acquiring all finger prints of 1,010 students from the Royal University of Cambodia, 600 Sokoto open data sets, and 98 Korean students. In order to determine if there are any injuries or wrinkles in the built database, criteria were established, and the data were validated by experts. The training and test datasets consisted of Cambodian data and Sokoto data, and the ratio was set to 8: 2. The data of 98 Korean students were set up as a validation data set. Using the constructed data set, five CNN-based architectures such as Classic CNN, AlexNet, VGG-16, Resnet50, and Yolo v3 were implemented. A study was conducted to find the model that performed best on the readings. Among the five architectures, ResNet50 showed the best performance with 81.51%.

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.