• Title/Summary/Keyword: soft transfer

Search Result 292, Processing Time 0.029 seconds

Development of Neural Network Model for Estimation of Undrained Shear Strength of Korean Soft Soil Based on UU Triaxial Test and Piezocone Test Results (비압밀-비배수(UU) 삼축실험과 피에조콘 실험결과를 이용한 국내 연약지반의 비배수전단강도 추정 인공신경망 모델 개발)

  • Kim Young-Sang
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.8
    • /
    • pp.73-84
    • /
    • 2005
  • A three layered neural network model was developed using back propagation algorithm to estimate the UU undrained shear strength of Korean soft soil based on the database of actual undrained shear strengths and piezocone measurements compiled from 8 sites over the Korea. The developed model was validated by comparing model predictions with measured values about new piezocone data, which were not previously employed during development of model. Performance of the neural network model was also compared with conventional empirical methods. It was found that the number of neuron in hidden layer is different for the different combination of transfer functions of neural network models. However, all piezocone neural network models are successful in inferring a complex relationship between piezocone measurements and the undrained shear strength of Korean soft soils, which give relatively high coefficients of determination ranging from 0.69 to 0.72. Since neural network model has been generalized by self-learning from database of piezocone measurements and undrained shear strength over the various sites, the developed neural network models give more precise and generally reliable undrained shear strengths than empirical approaches which still need site specific calibration.

The Cross-Leg Gastrocnemius Muscle Flap for Leg Reconstruction of the Difficult and Unfavorable Conditions (비복근을 이용한 교차하지 근육 피판술)

  • Kim, Ji Ye;Yang, Eun Jung;Hwang, Eun A;Kim, Sug Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.583-590
    • /
    • 2009
  • Purpose: In the cases of a vascular compromised condition in an injured lower extremity, soft tissue coverage with free tissue transfer presents a challenging problem to the reconstructive surgeon. For this reason, cross - leg flaps are still used in unusual circumstances. Advances in surgical technique has made the cross - leg free flap possible although it may require long operation time along with significant donor site morbidity. Therefore, a pedicled cross - leg muscle flap may be an alternative treatment modality when local flap or free flap is not possible. Methods: Twelve patients(9 males and 3 females) underwent the operation between October of 2001 and December of 2008. The patients' age ranged from 6 to 82 years. The unusual defects included the regions such as the knee, popliteal fossa, distal third of the tibia, dorsal foot, and the heel. Indications for the cross - leg gastrocnemius flap are inadequate recipient vessels for free flap(in eight cases), extensive soft tissue injuries(in three cases) and free flap failure(in one case). The muscle flap was elevated from contralateral leg and transferred to the soft tissue defect on the lower leg while both legs were immobilized with two connected external fixator systems. Delay procedure was performed 2 weeks postoperatively, and detachment was done after the establishment of the adequate circulation. The average period from the initial flap surgery to detachment was 32 days (3 to 6 weeks). Mean follow - up period was 4 years. Results: Stable coverage was achieved in all twelve patients without any flap complications. Donor site had minimal scarring without any functional and cosmetic problems. No severe complications such as deep vein thrombosis or flap necrosis were noted although mild to moderate contracture of the knee and ankle joint developed due to external fixation requiring 3 to 4 weeks of physical treatment. All patients were able to walk without crutches 3 months postoperatively. Conclusion: Although pedicled cross - leg flaps may not substitute free flap surgery, it may be an alternative method of treatment when free flap is not feasible. Using this modification of the gastrocnemius flap we managed to close successfully soft tissue defects in twelve patients without using free tissue transfers.

Tribological Characteristics of Diamond-like Carbon Films Based on Hardness of Mating Materials

  • Na, Byung-Chul;Tanaka, Akihiro
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.147-148
    • /
    • 2002
  • This study made use of four kinds of mating balls that were made with stainless steel but subjected to different annealing conditions in order to achieve different levels of hardness. In all load conditions, testing results demonstrated that the harder the mating materials, the lower the friction coefficient was. Conversely, the high friction coefficient found in soft martensite balls appeared to be caused by the larger contact area between the DLC film and the ball. Raman Spectra analysis showed that the transferred materials were a kind of graphite and that the contact surface of the DLC film seemed to undergo a phase transition from carbon to graphite during the high friction process.

  • PDF

MONTE CARLO SIMULATION OF COMPTONIZATION IN A SPHERICAL SHELL GEOMETRY

  • SEON KWANG IL;MIN KYOUNG WOOK;CHOI CHUL SUNG;NAM UK WON
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • We present the calculation of X -ray spectra produced through Compton scattering of soft X-rays by hot electrons in the spherical shell geometry, using fully relativistic Monte Carlo simulation. With this model, we show that the power-law component, which has been observed in the low luminosity state of low-mass X-ray binaries (LMXBs), is explained physically. From a spectral. analysis, we find that spectral hardness is mainly due to the relative contribution of scattered component. In addition, we see that Wi en spectral features appear when the plasma is optically thick, especially in the high energy range, $E{\gtrsim}100keV$. We suggest that after a number of scattering the escape probability approaches an asymptotic form depending on the geometry of the scattering medium rather than on the initial photon spectrum.

  • PDF

Implementation of Low-Speed Subscriber Interface in BSC(Base Station Controller) based on ATM (ATM 기반 기지국 제어기에서 저속 가입자 인터페이스 구현)

  • 박재영;최억우허용민홍진표
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.115-118
    • /
    • 1998
  • ATM(Asynchronous Transfer Mode)을 기반으로한 BSC(Base Station Controller)를 이용한 무선 이동통신망에서는 크게 MSC, BSC, BTS로 구성 되어진다. BSC는 MSC(Mobile Switch Center)와의 STM-1급 (155.52Mbps) 정합이 이루어지며, 여러 BTS(Base Transceiver Subsystem)와 T1(1.544Mbps)/E1(2.048Mbps)급 정합이 이루어져 호연결, 관리, 제어 및 MT(Mobile Terminal)의 soft-handoff를 담당한다. BSC내의 저속 가입자 I/F에서는 BTS와 BSC내의 ATM switch와의 정합을 수행하면서 VPI/VCI변환, BSC 내부 cell format으로 변환, 그리고 UPC(Usage Parameter Control)등이 이루어진다. 본 논문에서는 ATM switch를 이용한 BSC 내부의 저속 가입자 I/F의 구현에 관해서 살펴본다.

  • PDF

Biologic Arthroplasty of Elbow with Free Metatarso-Phalangeal Joint Transplantation (유리 중족-족지관절 이식술을 이용한 주관절 전치환술)

  • Chung, Duke Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.154-157
    • /
    • 2000
  • Author report a case of double metatarso-phalangeal joint transplantation to the elbow joint in the 31 years old female patient who have large bone defect associated with skin and soft tissue defect. The donor joints were second and third metatarso-phalangeal joint as double joint transfer fashion to enhance stability of graft. The graft based on dorsalis pedis vessel to anastomosed with radial artery of recipient site. The result is unsatisfactory because of long lasting lateral instability of reconstructed elbow joint in spite of 40 degree flexion motion and fair axial stability. We can conclude that joints from foot can not be an effective donor for biologic joint arthroplasty of elbow joint even though double metatarso-phalangeal joint were harvested.

  • PDF

Reverse Total Shoulder Arthroplasty in the Massive Rotator Cuff Tear

  • Jeong, Jin Young;Cha, Hong Eun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.145-150
    • /
    • 2014
  • In the patients of retracted massive rotator cuff tears, there are much of difficulty to functional recovery and pain relief. Nevertheless the development of treatment, there are still debates of the best treatments in the massive rotator cuff tears. Recenlty various of treatments are introduced; these are acromioplasty with debridement, biceps tenotomy, great tuberoplasty with biceps tenotomy, partial repair, mini-open rotator cuff repair, arthroscopic rotator cuff repair, soft tissue augmentation, tendon transfer, flap, hemiarthroplasty, and reverse total shoulder arthroplasty. That there is no difference of result for reverse total shoulder arthroplasty between patients who have massive rotator cuff tear without arthritis and patients who have cuff tear arthropathy. Reverse total shoulder arthroplasty is one of reliable and successful treatment options for massive rotator cuff tear. Especially it is more effective for patients who have a pseudoparalysis.

Shear Load characteristics of drilled shafts considering socket-roughness in Constant Normal Stiffness(CNS) Test (일정수직강성시험을 통한 암반근입 현장타설말뚝의 주면마찰력특성분석)

  • Jeong, Sang-Seom;Jung, Woo-Hyun;Seol, Hoon-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.489-498
    • /
    • 2005
  • In this study, the shaft resistance of drilled shafts socketed into weathered-and soft-rocks was examined by the constant normal stiffness(CNS) test. Large scale model tests were performed for different unconfined compressive strength, socket roughness, initial normal stress, and normal stiffness for identifying shear load transfer characteristics. Through comparisons with previous studies, it is found that the results by the present approach is good agreement with the general trend observed by existing empirical and analytical results.

  • PDF

Design and Implementation of PC Based Multi-Image Transfer System (PC기반의 다중 이미지 전송 시스템 설계 및 구현)

  • 석길원;이남경;정대현;이동춘;이종원;유관우
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.328-330
    • /
    • 2001
  • 본 논문에서는 가정용 PC상에서 별도의 장치 없이 구축할 수 있는 다중 이미지 전송 시스템을 구현한다. 구현한 시스템은 한 대의 PC에서 여러 대의 카메라를 사용하여 이미지를 캡춰하는 장점이 있다. 또한 PC에서도 많은 부하를 주지 않아 시스템의 안정성을 보장한다. 네트워크의 상황에 따라 적절하게 대처함으로써, 영상의 전송율을 일정하게 유지한다. 정지 영상을 이용한 시스템이지만, 동영상의 경우와 거의 차이가 없다. 본 논문의 보안시스템은 간단한 구조와 저렴한 비용으로 인해, 일반인도 쉽게 구축할 수 있다. 산업재해감시, 상가의 도난방지, 유치원의 아동관찰 등의 여러 용도로 쓰일 수 있다.

  • PDF