• Title/Summary/Keyword: soft transfer

Search Result 292, Processing Time 0.029 seconds

RECONSTRUCTION OF MIDFACIAL DEFECTS UTILIZING RECTUS ABDOMINIS FREE FLAP : REPORT OF 2 CASES (유리 복직근 피판을 이용한 중안모 결손부 재건의 2 치험례)

  • Lee, Seong-Geun;Sung, Iel-Yong;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.98-104
    • /
    • 2000
  • Expansion in the scope and technique of head and neck tumor resection during the past two decades has paralleled precise tumor localization with advanced radiographic imaging and the availability of microvascular free tissue transfer. Especially, the defect reconstruction utilizing free flap results in improvement of patient survival due to decrease of local recurrence by wide resection of cancer. The rectus abdominis free flap has been used widely in reconstruction of the breast and extremities. However, the report of cases on its applications in the head and neck, based on the deep inferior epigastric artery and vein, is rare. This flap is one of the most versatile soft-tissue flaps. The deep inferior epigastric artery and vein are long and large-diameter vessels that are ideal for microvascular anastomosis. The skin area that can be transferred is probably the largest of all flaps presently in use. The versatility of the donor site is due to the ability to transfer large areas of skin with various thickness and amounts of underlying muscle. This article is to report reconstruction of midface defects utilizing the rectus abdominis free flap in 2 patients with maxillary squamous cell carcinoma and discuss briefly considerations in flap design and orbital exenteration, and healing of irradiated recipient site by hyperbaric oxygen therapy with literature review.

  • PDF

LMTT Positioning System Control using DR-FNN (DR-FNN을 이용한 LMTT Positioning System 제어)

  • Lee, Jin-Woo;Sohn, Dong-Sop;Min, Jung-Tak;Lee, Kwon-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2206-2208
    • /
    • 2003
  • LMTT(Linear Motor-based Transfer Technology) is horizontal transfer system in the maritime container terminal for the port automation. The system is modeled PMLSM(Permanent Magnetic Linear Synchronous Motor) that is consists of stator modules on the rail and shuttle car(mover). Because of large variant of movers weight by loading and unloading containers, the difference of each characteristic of stator modules, and a stator module's default etc., LMCS(Linear Motor Conveyance System) is considered as that the system is changed its model suddenly and variously. In this paper, we will introduce the soft-computing method of a multi-step prediction control for LMCS using DR-FNN(Dynamically Constructed Recurrent Fuzzy Neural Network). The proposed control system is used two networks for multi-step prediction. Consequently, the system has an ability to adapt for external disturbance, cogging force, force ripple, and sudden changes of itself.

  • PDF

A Study on Polymer Replica Materials for Nanotransfer Printing (패턴전사프린팅용 고분자 복제 소재 연구)

  • Kang, Young Lim;Park, Woon Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.4
    • /
    • pp.262-268
    • /
    • 2021
  • For the past several decades, various next-generation patterning methods have been developed to obtain well-designed nano-to-micro structures, such as imprint lithography, nanotransfer printing (nTP), directed self-assembly (DSA), E-beam lithography, and so on. Especially, nTP process has much attention due to its low processing cost, short processing time, and good compatibility with other patterning techniques in achieving the formation of high-resolution functional patterns. To transfer functional patterns onto desirable substrates, the use of soft materials is required for precise replication of master mold. Here, we introduce a simple and practical nTP method to create highly ordered structures using various polymeric replica materials. We found that polymethyl methacrylate (PMMA), polystyrene (PS), and polyvinylpyridine (PVP) are possible candidates for replica materials for reliable duplication of Si master mold based on systematic analysis of pattern visualization. Furthermore, we successfully obtained well-defined metal and oxide nanostructures with functionality on target substrates by using replica patterns, through deposition and transfer process. We expect that the several candidates of replica materials can be exploited for effective nanofabrication of complex electronic devices.

Experimental study on the longitudinal load transfer of a shallow tunnel depending on the deformation tunnel face (II) (얕은 터널의 굴진면 변형에 따른 종방향 하중전이 특성에 대한 실험적 연구(II))

  • Kim, Yang Woon;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.499-509
    • /
    • 2016
  • In recent years, the use of underground spaces becomes more frequent and the demands for urban tunnels are rapidly increasing. The urban tunnels constructed in the ground with a shallow and soft cover might be deformed in various forms on the face, which would lead, the tunnels to behavior 3-dimensionally, which may have a great impact on the longitudinal load transfer. The tunnel face might deform in various forms depending on the construction method, overburden and the heterogeneity of the ground. And accordingly, the type and size of the distribution of the load transferred to the ground adjacent to the tunnel face as well as the form of the loosened ground may appear in various ways depending on the deformation form of the tunnel face. Therefore, in this study was conducted model tests by idealizing the deformation behavior of the tunnel face, that were constant deformation, the maximum deformation on the top and the maximum deformation on the bottom. And the test results were analyzed focusing on the deformation of the face and the longitudinal load transfer at the ground above the tunnel. As results, it turned out that the size and the distribution type of the load, which was transferred to the tunnel as well as the earth pressure on the face were affected by the deformation type of the face. The largest load was transferred to the tunnel when the deformation was in a constant form. Less load was transferred when the maximum deformation on the bottom, and the least load was transferred when the maximum deformation on the top. In addition, it turned out that, if the cover became more shallow, a longitudinal load transfer in the tunnel would limited to the region close to the face; however, if the cover became higher than a certain value, the area of the load transfer would become wider.

Contact Transfer Printing Using Bi-layer Functionalized Nanobio Interface for Flexible Plasmonic Sensing

  • Lee, Jihye;Park, Jiyun;Lee, Junyoung;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.413-413
    • /
    • 2014
  • In this paper, we present a fabrication method of functionalized gold nanostructures on flexible substrate that can be implemented for plasmonic sensing application. For biomolecular sensing, many researchers exploit unconventional lithography method like nanoimprint lithography (NIP), contact transfer lithography, soft lithography, colloidal transfer printing due to its usability and easy to functionalization. In particular, nanoimprint and contact transfer lithography need to have anti-adhesion layer for distinctive metallic properties on the flexible substrates. However, when metallic thin film was deposited on the anti-adhesion layer coated substrates, we discover much aggravation of the mold by repetitive use. Thus it would be impossible to get a high quality of metal nanostructure on the transferred substrate for developing flexible electronics based transfer printing. Here we demonstrate a method for nano-pillar mold and transfer the controllable nanoparticle array on the flexible substrates without an anti-adhesion layer. Also functionalization of gold was investigated by the different length of thiol applied for effectively localized surface plasmonic resonance sensing. First, a focused ion beam (FIB) and ICP-RIE are used to fabricate the nanoscale pillar array. Then gold metal layer is deposited onto the patterned nanostructure. The metallic 130 nm and 250 nm nanodisk pattern are transferred onto flexible polymer substrate by bi-layer functionalized contact imprinting which can be tunable surface energy interfaces. Different thiol reagents such as Thioglycolic acid (98%), 3-Mercaptopropionic acid (99%), 11-Mercaptoundecanoic acid (95%) and 16-Mercaptohexadecanoic acid (90%) are used. Overcoming the repeatedly usage of the anti-adhesion layer mold which has less uniformity and not washable interface, contact printing method using bi-layer gold array are not only expedient access to fabrication but also have distinctive properties including anti-adhesion layer free, functionalized bottom of the gold nano disk, repeatedly replicate the pattern on the flexible substrate. As a result we demonstrate the feasibility of flexible plasmonic sensing interface and anticipate that the method can be extended to variable application including the portable bio sensor via mass production of stable nanostructure array and other nanophotonic application.

  • PDF

Estimation of Critical Height of Embankment to Mobilize Soil Arching in Pile-supported Embankment (말뚝지지성토지반 내 지반아칭이 발달할 수 있는 한계성토고의 평가)

  • Hong, Won-Pyo;Hong, Seong-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.11
    • /
    • pp.89-98
    • /
    • 2010
  • A method to design a critical height of embankments is presented so as to mobilize fully soil arching in pile-supported embankments. The behavior of the load transfer of embankment weights on pile cap beams was investigated by a series of model tests performed on pile-supported embankments with relatively wide space between cap beams. The model tests explained that the behavior of the load transfer depended very much on the height of embankments, because soil arching could be mobilized in pile-supported embankments only under enough high embankments. The measured vertical loads on cap beams coincided with the predicted ones estimated by the theoretical equations, which have been presented in the previous studies on the basis of load transfer mechanisms according to either the punching shear failure mode during low filling stage or the soil arching failure mode during high filling stage. The mechanism of the load transfer was shifted beyond a critical height of embankment from the punching shear mechanism to the soil arching mechanism. Therefore, in order to mobilize soil arching in pile-supported embankments, the embankments should be designed at least higher than the critical height. A theoretical equation to estimate the critical height could be derived by equalizing the vertical loads estimated by the load transfer mechanisms on the basis of both the punching shear and the soil arching. The derived theoretical equation could predict very well the experimental critical height of embankment.

Surgical Treatment of Radial Nerve Injury (요골 신경 손상의 수술적 치료)

  • Lee, Kwang-Suk;Park, Sang-Won;Wie, Dae-Gon
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.128-136
    • /
    • 1996
  • Radial nerve injury is caused by variety of etiologies, mainly traumatic. It is primarily a motor nerve and loss of it's function leads to a significant disability. Surgical treatments of radial nerve comprise of neurolysis(internal or external), neurorrhaphy(eineural, perineural or epi-perineural), nerve graft and tendon transfer. However, there is still controversies in treatment methods and time of operation. Authors experienced 23 cases of radial nerve injuries who were treated by operative methods and followed up over 1 year's duration. The male to female ratio was 18 to 5 and mean age was 30.7 years old. The causes were 13 cases in fractures, 5 cases in crushing injury, 3 cases in laceration, 1 case in CO poisoning and 1 case in unknown cause. The summary of the study were as follows ; 1. Excellent or good results were obtained in overall 16 cases among 23 cases; 5 of 9 cases in neurolysis, 3 of 3 cases in neurorrhaphy, 2 of 3 cases in nerve graft and 6 of 8 cases in tendon transfer. 2. In cases of neurorrhaphy and nerve graft, primary or delayed repair showed excellent or good results and neurolysis performed before 6 months leads to better results. But there was no correlations between the time of injury and operation in tendon transfer. 3. The radial nerve injury associated with extensive soft tissue defect or any conditions that leads to nerve ischemia results poor prognosis. 4. The patients aged under 40 years showed better prognosis in clinical results according to the age of surgical treatment. 5. If the surgeon decide the method and the time of operation through the exact evaluation of the factors which influencing the end result such as age of the patient, level and type of injury, extent of nerve lesion and the associated tissue injury, good result could be expected.

  • PDF

Analysis of Free Flap Reconstruction of the Tongue (유리피판을 이용한 설재건술의 분석)

  • Kang, Dong Hee;Lee, Hyung Chul;Koo, Sang Hwan;Park, Seung Ha;Jung, Kwang Yoon
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.557-562
    • /
    • 2006
  • Purpose: Advanced carcinoma of the tongue is a devastating disease which may cause severe speech or swallowing dysfunction. But, none to date has provided all of the complex functions of the tongue. The purpose of this study is to review our experiences with individuals who underwent glossectomy followed by reconstruction using free tissue transfer. Methods: Between February 1998 and February 2005, twenty-four patients underwent glossectomy followed by free tissue transfer reconstruction. The defects of tongue caused by partial or subtotal glossectomy were reconstructed by means of radial forearm or lateral thigh free flap with nerve innervation. Especially for the patients who underwent total glossectomy, we reconstructed deglutition muscles anatomically with nerve reinnervation, a procedure that allows the grafted muscle to maintain good tongue bulk without obvious atrophy. Results: Patients were reviewed to determine their functional outcome as it related to speech, deglutition, and aspiration. All patients achieved oral intake of a soft diet and acceptable speech. Conclusion: Although reconstruction following glossectomy using free tissue transfer is not ideal, this procedure is safe and reliable, and provides predictable results. A future challenge is the development of a surgical procedure for reconstruction of a tongue that maintains mobility and sensation using neurotized flaps.

Model Tests for Vertical Loads Acting on Embankment Piles (성토지지말뚝에 작용하는 연직하중에 대한 모형실험)

  • 홍원표;강승인
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.171-181
    • /
    • 2000
  • A series of model tests were performed both to investigate the load transfer by soil acrching in fills above embankment pils and to verify of the theoretical analysis. In the model tests, the piles were installed in a row below the embankment and the cap beams were placed on the pile heads perpendicular to the longitudinal axias of the embankment. The space between pile cap beams and the embankment height was focused as the major factors affecting the load transfer in embankment fill. When the embankment fill was higher than the minimum required height, which was about 33% higher than the radius of the soil arch proposed by theoretical discussion in the previous study, not only the soil arching could be developed completely but also the experimental results showed good agreement with theoretical predictions. The portion of the embankment load carried by model pile cap beams decreased with increment of the space between pile cap beams, while it increased with increment of the embankment height. Therefore, to maximize the effect of embankment load transfer by piles on design, the interval ratio of pile cap beams should be decreased under considerably high embankments by reducing the space between cap beams and/or enlarging the width of pile cap beams.

  • PDF

Free Vascularized Osteocutaneous Fibular Graft to the Tibia (경골에 시행한 유리 생 비골 및 피부편 이식)

  • Lee, Kwang-Suk;Park, Jong-Woong;Ha, Kyoung-Hwan;Han, Sang-Seok
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.63-72
    • /
    • 1997
  • We have evaluated the clinical results following the 46 cases of free vascularized osteocutaneous fibular flap transfer to the tibial defect combined with skin and soft tissue defect, which were performed from May 1982 to January 1997. Regarding to the operation, flap size, length of the grafted fibula, anastomosed vessels, ischemic time of the flap and total operation time were measured. After the operation, time to union of grafted fibula and the amount of hypertrophy of grafted fibula were periodically measured through the serial X-ray follow-up and also the complications and results of treatment were evaluated. In the 46 consecutive procedures of free vascularized osteocutaneous fibular flap transfer, initial bony union were obtained in the 43 grafted fibulas at average 3.75 months after the operation. There were 2 cases in delayed unions and 1 in nonunion. 44 cutaneous flaps among the 46 cases were survived but 2 cases were necrotized due to deep infection and venous insufficiency. One necrotized flap was treated with latissimus dorsi free flap transfer and the other was treated with soleus muscle rotational flap. Grafted fibulas have been hypertrophied during the follow-up periods. The fracture of grafted fibula(15 cases) was the most common complication and occurred at average 9.7 months after the operation. The fractured fibulas were treated with the cast immobilization or internal fixation with conventional cancellous bone graft. In the cases of tibia and fibula fracture at recipient site, the initial rigid fixation for the fibula fracture at recipient site could prevent the fracture of grafted fibula to the tibia.

  • PDF