• Title/Summary/Keyword: soft threshold

Search Result 115, Processing Time 0.027 seconds

A Study on an Error Correction Code Circuit for a Level-2 Cache of an Embedded Processor (임베디드 프로세서의 L2 캐쉬를 위한 오류 정정 회로에 관한 연구)

  • Kim, Pan-Ki;Jun, Ho-Yoon;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Microprocessors, which need correct arithmetic operations, have been the subject of in-depth research in relation to soft errors. Of the existing microprocessor devices, the memory cell is the most vulnerable to soft errors. Moreover, when soft errors emerge in a memory cell, the processes and operations are greatly affected because the memory cell contains important information and instructions about the entire process or operation. Users do not realize that if soft errors go undetected, arithmetic operations and processes will have unexpected outcomes. In the field of architectural design, the tool that is commonly used to detect and correct soft errors is the error check and correction code. The Itanium, IBM PowerPC G5 microprocessors contain Hamming and Rasio codes in their level-2 cache. This research, however, focuses on huge server devices and does not consider power consumption. As the operating and threshold voltage is currently shrinking with the emergence of high-density and low-power embedded microprocessors, there is an urgent need to develop ECC (error check correction) circuits. In this study, the in-output data of the level-2 cache were analyzed using SimpleScalar-ARM, and a 32-bit H-matrix for the level-2 cache of an embedded microprocessor is proposed. From the point of view of power consumption, the proposed H-matrix can be implemented using a schematic editor of Cadence. Therefore, it is comparable to the modified Hamming code, which uses H-spice. The MiBench program and TSMC 0.18 um were used in this study for verification purposes.

Three-dimensional analysis of soft and hard tissue changes after mandibular setback surgery in skeletal Class III patients (골격성 3급 부정교합 환자의 하악골 후퇴술 시행후 안모변화에 대한 3차원적 연구)

  • Park, Jae-Woo;Kim, Nam-Kug;Kim, Myung-Jin;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.320-329
    • /
    • 2005
  • The three-dimensional (3D) changes of bone, soft tissue and the ratio of soft tissue to bony movement was investigated in 8 skeletal Class III patients treated by mandibular setback surgery. CT scans of each patient at pre- and post-operative states were taken. Each scan was segmented by a threshold value and registered to a universal three-dimensional coordinate system, consisting of an FH plane, a mid-sagittal plane, and a coronal plane defined by PNS. In the study, the grid parallel to the coronal plane was proposed for the comparison of the changes. The bone or soft tissue was intersected by the projected line from each point on the gird. The coordinate values of intersected point were measured and compared between the pre- and post-operative models. The facial surface changes after setback surgery occurred not only in the mandible, but also in the mouth corner region. The soft tissue changes of the mandibular area were measured relatively by the proportional ratios to the bone changes. The ratios at the mid-sagittal plane were $77\~102\%(p<0.05)$. The ratios at all other sagittal planes had similar patterns to the mid-sagittal plane, but with decreased values. And, the changes in the maxillary region were calculated as a ratio, relative to the movement of a point representing a mandibular movement. When B point was used as a representative point, the ratios were $14\~29\%$, and when Pog was used, the ratios were $17\~37\%(9<0.05)$. In case of the 83rd point of the grid, the ratios were $11\~22\%(p<0.05)$.

The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials (신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구)

  • Ma, Sang-Chull;Kim, Hwa-Sun;Ann, Young-Man
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This study analyzed speed of sound, impedance, attenuation coefficient in accordance with acoustic characteristic standard of body soft tissue corresponding with Annex DD of IEC standard 60601-2-37(2007) which is about tissue mimicking materials (TMM) synthesized by polyurethane as a main material and new type of n-type scatter materials. This study reached the following conclusion after analyzing and evaluating image characteristic with SONOACE 9900 c PRIME (MEDESON Co.) and brightness, maximum penetration with convex probe (2.5~5.0 MHz). When n-type scatter materials are increasingly synthesised 0~8% with prepolymer as a main material and polyol mixture as a catalyst, 1. The more scatter materials are increased, the more sound speed of TMM becomes closely similar to soft tissue. 2. The more scatter materials are decreased, the more acoustic impedance becomes closely similar to soft tissue. 3. The more scatter materials are increased, the more attenuation coefficient is increased. 4. The more scatter materials are increased, the more average brightness of images is increased, but there is threshold. 5. The maximum penetration becomes closely similar to soft tissue at the 6% TMM as a scatter material.

Classical Tamil Speech Enhancement with Modified Threshold Function using Wavelets

  • Indra., J;Kasthuri., N;Navaneetha Krishnan., S
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1793-1801
    • /
    • 2016
  • Speech enhancement is a challenging problem due to the diversity of noise sources and their effects in different applications. The goal of speech enhancement is to improve the quality and intelligibility of speech by reducing noise. Many research works in speech enhancement have been accomplished in English and other European Languages. There has been limited or no such works or efforts in the past in the context of Tamil speech enhancement in the literature. The aim of the proposed method is to reduce the background noise present in the Tamil speech signal by using wavelets. New modified thresholding function is introduced. The proposed method is evaluated on several speakers and under various noise conditions including White Gaussian noise, Babble noise and Car noise. The Signal to Noise Ratio (SNR), Mean Square Error (MSE) and Mean Opinion Score (MOS) results show that the proposed thresholding function improves the speech enhancement compared to the conventional hard and soft thresholding methods.

A Study on Wavelet-based Image Denoising Using a Modified Adaptive Thresholding Method

  • Yinyu, Gao;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.45-52
    • /
    • 2012
  • Thedenoising of a natural image corrupted by Gaussian noise is a long established problem in signal or image processing. Today the research is focus on the wavelet domain, especially using the wavelet threshold method. In this paper, a waveletbased image denoising modified adaptive thresholding method is proposed. The proposed method computes thethreshold adaptively based on the scale level and adaptively estimates wavelet coefficients by using a modified thresholding function that considers the dependency between the parent coefficient and child coefficient and the soft thresholding function at different scales. Experimental results show that the proposed method provides high peak signal-to-noise ratio results and preserves the detailed information of the original image well, resulting in a superior quality image.

Pain-relieving Effect of the PAS Release Applied to Tender Points (압통점에 적용한 파스이완술이 통증에 미치는 영향)

  • Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.53-58
    • /
    • 1999
  • PURPOSE; The main purpose of physical therapy is to minimize patient's pain. So this study aimed at evaluating the effect of PAS release applied to tender points in reducing pain of musculoskeletal lesion persons. METHOD; The PAS (capsicum plaster) Release applied at 48 tender points to relieve and assessment pain threshold by Harold Gottlieb's pain scale that was composed of Negligible sensation 4.00, Mild sensation 3.00, Moderate sensation 2.00, Severe sensation 1.00. RESULT; Results show that PAS release was 84.6% effect in achieving a gradual decrease of pain sensitivity at the tender points where it was applied, suggestion a cumulative analgesic effect through sessions. CONCLUSION; This study suggests that PAS release applied to tender points can be effective in relieving soft tissue pain through theses have not become asymptomatic, all referred significant pain relief(p <0.05) after study and at the end of PAS release therapy.

  • PDF

Technical Trends of Metal Nanowire-Based Electrode (금속 나노와이어 기반 전극 기술 개발 동향)

  • Shin, Yoo Bin;Ju, Yun Hee;Kim, Jong-Woong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.15-22
    • /
    • 2019
  • Metallic nanowires (MNWs) have recently been considered as one of the most promising candidates for flexible electrodes of advanced electronics including wearable devices, electronic skins, and soft robotics, since they have high aspect ratio in physical shape, low percolation threshold, high ductility and optical transparency. Herein, we review the latest findings related to the MNWs and discuss the properties and potentials of this material that can be used in implementation of various advanced electronic devices.

Fast Volume Visualization Techniques for Ultrasound Data

  • Kwon Koo-Joo;Shin Byeong-Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.6-13
    • /
    • 2006
  • Ultrasound visualization is a typical diagnosis method to examine organs, soft tissues and fetus data. It is difficult to visualize ultrasound data because the quality of the data might be degraded by artifact and speckle noise, and gathered with non-linear sampling. Rendering speed is too slow since we can not use additional data structures or procedures in rendering stage. In this paper, we use several visualization methods for fast rendering of ultrasound data. First method, denoted as adaptive ray sampling, is to reduce the number of samples by adjusting sampling interval in empty space. Secondly, we use early ray termination scheme with sufficiently wide sampling interval and low threshold value of opacity during color compositing. Lastly, we use bilinear interpolation instead of trilinear interpolation for sampling in transparent region. We conclude that our method reduces the rendering time without loss of image quality in comparison to the conventional methods.

An Efficient Binarization Method for Vehicle License Plate Character Recognition

  • Yang, Xue-Ya;Kim, Kyung-Lok;Hwang, Byung-Kon
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.12
    • /
    • pp.1649-1657
    • /
    • 2008
  • In this paper, to overcome the failure of binarization for the characters suffered from low contrast and non-uniform illumination in license plate character recognition system, we improved the binarization method by combining local thresholding with global thresholding and edge detection. Firstly, apply the local thresholding method to locate the characters in the license plate image and then get the threshold value for the character based on edge detector. This method solves the problem of local low contrast and non-uniform illumination. Finally, back-propagation Neural Network is selected as a powerful tool to perform the recognition process. The results of the experiments i1lustrate that the proposed binarization method works well and the selected classifier saves the processing time. Besides, the character recognition system performed better recognition accuracy 95.7%, and the recognition speed is controlled within 0.3 seconds.

  • PDF

Mastitis Detection by Near-infrared Spectra of Cows Milk and SIMCA Classification Method

  • Tsenkova, R.;Atanassova, S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1248-1248
    • /
    • 2001
  • Mastitis is a major problem for the global dairy industry and causes substantial economic losses from decreasing milk production and considerable compositional changes in milk, reducing milk quality. The potential of near infrared (NIR) spectroscopy in the region from 1100 to 2500nm and chemometric method for classification to detect milk from mastitic cows was investigated. A total of 189 milk samples from 7 Holstein cows were collected for 27 days, consecutively, and analyzed for somatic cells (SCC). Three of the cows were healthy, and the rest had mastitis periods during the experiment. NIR transflectance milk spectra were obtained by the InfraAlyzer 500 spectrophotometer in the spectral range from 1100 to 2500nm. All samples were divided into calibration set and test set. Class variable was assigned for each sample as follow: healthy (class 1) and mastitic (class 2), based on milk SCC content. The classification of the samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two concentration of SCC - 200 000 cells/ml and 300 000 cells/ml, respectively, were used as thresholds fer separation of healthy and mastitis cows. The best detection accuracy was found for models, obtained using 200 000 cells/ml as threshold and smoothed absorbance data - 98.41% from samples in the calibration set and 87.30% from the samples in the independent test set were correctly classified. SIMCA results for classes, based on 300 000 cells/ml threshold, showed a little lower accuracy of classification. The analysis of changes in the loading of first PC factor for group of healthy milk and group of mastitic milk showed, that separation between classes was indirect and based on influence of mastitis on the milk components. The accuracy of mastitis detection by SIMCA method, based on NIR spectra of milk would allow health screening of cows and differentiation between healthy and mastitic milk samples. Having SIMCA models, mastitis detection would be possible by using only DIR spectra of milk, without any other analyses.

  • PDF