• 제목/요약/키워드: soft conversion

검색결과 174건 처리시간 0.032초

새로운 유도가열용 소프트 스위칭 고주파 인버터 (Soft Switching High Frequency Inverter for New Induction Heating)

  • 김칠용;문상필;김영문;김해재;류재엽;김수욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

PPS 제어기법을 적용한 48V-400V 비절연 양방향 DC-DC컨버터 (A 48V-400V Non-isolated Bidirectional Soft-switching DC-DC Converter for Residential ESS)

  • 정현주;권민호;최세완
    • 전력전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.190-198
    • /
    • 2018
  • This paper proposes a nonisolated, bidirectional, soft-switching DC - DC converter with PWM plus phase shift (PPS) control. The proposed converter has an input-parallel/output-series configuration and can achieve the interleaving effect and high voltage gains, resulting in decreased voltage ratings in all related devices. The proposed converter can operate under zero-voltage switching (ZVS) conditions for all switches in continuous conduction mode. The power flow of the proposed converter can be controlled by changing the phase shift angle, and the duty is controlled to balance the voltage of four high voltage side capacitors. The PPS control device of the proposed converter is simple in structure and presents symmetrical switching patterns under a bidirectional power flow. The PPS control also ensures ZVS during charging and discharging at all loads and equalizes the voltage ratings of the output capacitors and switches. To verify the validity of the proposed converter, an experimental investigation of a 2 kW prototype is performed in both charging and discharging modes under different load conditions and a bidirectional power flow.

절연형 DCM DC-DC 컨버터에 관한 연구 (A Study on Isolated DC-DC Converter of DCM)

  • 곽동걸;이봉섭;김춘삼;심재선;유주희;손재현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.15-16
    • /
    • 2010
  • This paper is study on a high efficiency DC-DC converter of discontinuous conduction mode (DCM) added electric isolation. The converters of high efficiency are generally made that the power losses of the used semiconductor switching devices is minimized. To achieve high efficiency system, the proposed converter is constructed by using a quasi resonant circuit. The control switches using in the converter are operated with soft switching by quasi resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of the system is high. The proposed converter is also added electric isolation which is used a pulse transformer. When the power conversion system is required electric isolation, the proposed converter is adopted with the converter system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter are verified by digital simulation and experimental results.

  • PDF

Study of the Distribution Properties and LRFD Code Conversion in Japanese Larch

  • Park, Chun-Young;Pang, Sung-Jun;Park, Ju-Sang;Kim, Kwang-Mo;Park, Mun-Jae;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권2호
    • /
    • pp.94-100
    • /
    • 2010
  • This study was performed to develop an LRFD (Load Resistance Factored Design) Code for Domestic Larch. To accomplish his, we evaluated bending, compression, tension and shear strength. The results of the strength evaluation were utilized to verify the distribution and code conversion. For bending, tension and compressive strength, the Weibull distribution was well-fitted, but for shear strength we observed a normal distribution. For evaluating the bending and compressive strength, a full-sized specimen was used. A small clear specimen was used to test tension and shear strength. Compressive strength in particular was found to be affected by tight knots, although there was little difference between grades. In the code conversion, the design value of the LRFD was larger than the existing allowable stress value in the Korean Building Code. However, the allowable stress in this study was about two times higher than the value listed in the Korean Building Code. This result induced the difference between the soft and hard conversions. For greater reliability, the accumulation of additional data is necessary and further studies should be performed

Percutaneous Endoscopic Thoracic Discectomy : Posterolateral Transforaminal Approach

  • Lee, Ho-Yeon;Lee, Sang-Ho;Kim, Dong-Yun;Kong, Byoung-Joon;Ahn, Yong;Shin, Song-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권1호
    • /
    • pp.58-62
    • /
    • 2006
  • Objective : Development of diagnostic tools has resulted in early detection of thoracic disc herniations[TDH] even when the herniated disc is soft in consistency. In some of the cases, it is considered better not to opt for surgical treatment due to the unduly high morbidity and potential complications associated with conventional approaches. The authors have applied percutaneous endoscopic thoracic discectomy[PETD] technique to soft TDHs in order to avoid the morbidity associated with conventional approaches. Methods : Eight consecutive patients [range, 31 to 75 years] with soft lateral or central TDH [from T2-3 to T11-12] underwent PETD between May 2001 and June 2004. The patient was positioned in a prone position with intravenous sedation and local anesthetic infiltration. The authors introduced a cannula into the thoracic intervertebral foramen using endoscopic foraminoplasty technique. Discectomy was performed with mechanical tools and a laser under continuous endoscopic visualization and flu oroscopic guidance. Functional status was assessed preoperatively and postoperatively using the Oswestry Disability Index[ODI]. Results : The mean ODI scores improved from 52.8 before the surgery to 25.8 at the final follow-up. In cases of myelopathy, long tract signs showed improvement. The mean operative time was 55 minutes, and no patient required conversion to open surgery. Conclusion : The technique allows a smaller incision and less morbidity. Soft TDH is amenable to this minimally invasive approach in selected patients with myeloradiculopathy.

Examination of Frequency Dependence of Iron Loss in Magnetic Field Analysis

  • Masato Enokizono;Yuji Fujita
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.59-63
    • /
    • 2001
  • This paper presents a new modeling of the two dimensional magnetic property in soft magnetic materials for the magnetic field computations. In this modeling an approximate treatment is introduced to expand the applicable exciting frequency range. The result shows that the new modeling presented here is very useful in simplicity of magnetic field analysis.

고승압 소프트스위칭 양방향 컨버터의 충방전 모드전환 기법 (Charge/Discharge Mode Conversion Method of Bi-directional Soft-switching Converter with High Voltage Gain)

  • 권민호;정헌수;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.185-186
    • /
    • 2012
  • 본 논문에서는 고승압 소프트스위칭 양방향 컨버터의 스위칭 모드절환 시점을 제안하여 전류의 불연속 구간이 발생되지 않는 방법을 소개하여 일반적인 부스트 컨버터와 같이 일반적인 제어 알고리즘을 적용 가능함을 검증하였고 시뮬레이션 및 실험을 통해 타당성을 검증하였다.

  • PDF

3상/단상 직접형 전력변환시스템의 소프트스위칭 제어기법 (Soft Switching Control Scheme for 3-Phase to Single Phase Direct Power Conversion System)

  • 조춘호;최명수;김성곤;김태웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.193-194
    • /
    • 2015
  • 신재생에너지를 이용한 발전 기술 중에 있어서 풍력발전기술은 특히 발전하고 있다. 그 결과, 풍력발전으로 생산한 전력량은 매년 증가하고 있다. 본 논문에서는 풍력발전기의 계통연계를 위한 소프트스위칭이 가능한 3상/단상 직접형 전력변환시스템의 SV-PWM 제어기법을 제안한다. 또한 시뮬레이션을 통해 제안된 알고리즘의 유효성을 검증한다.

  • PDF

새로운 고효율 절연형 스텝 업-다운 DC/DC 초퍼에 관한 연구 (A Study on Novel Step Up-Down DC/DC Chopper of Isolated Type with High Efficiency)

  • 곽동걸
    • 전기전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.82-88
    • /
    • 2009
  • 본 논문에서는 새로운 고효율의 절연형 스텝 업-다운 DC/DC 초퍼에 대해 해석하였다. 일반적으로 고효율의 초퍼를 만들기 위해서는 전력변환기내에 사용된 반도체 스위칭 소자의 손실이 최소화 되어야 한다. 본 논문에서는 부분공진 회로를 초퍼에 추가하여 고효율을 실현시킨다. 제안한 초퍼에 사용된 제어용 스위칭 소자들은 부분공진기법에 의해 소프트 스위칭으로 동작하고, 이에 따른 제어용 스위칭 소자들은 전압과 전류의 스트레스 없이 동작한다. 그 결과 제안한 초퍼는 스위칭 손실의 저감에 의해 고효율로 구동한다. 그리고 제안한 초퍼는 펄스 변압기를 이용하여 입력단과 출력단을 절연시켜, 전기적 절연이 요구되는 전력변환기들에 적용되어 고효율의 전력변환시스템을 개발할 수 있는 장점이 부여된다. 제안한 절연형 스텝 업-다운 초퍼의 소프트 스위칭 동작과 시스템 효율은 다양한 시뮬레이션과 실험결과를 통해 그 타당성이 입증된다.

  • PDF