• Title/Summary/Keyword: soft contact lens

Search Result 120, Processing Time 0.022 seconds

The comparative of Naringin and Chitosan using Natural preservation agents by LM and TEM (천연보존제 나린진과 키토산의 비교....LM & TEM적 소견)

  • Kim, In-Suk;Yoo, Geun-Chang;Chae, Soo-Chul;Lee, Chong-Bin;Jeon, Chang-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.283-292
    • /
    • 2005
  • This study investigated the effects of naringin, and chitosan in rabbits' corneas. Naringin, a glycone of naringenin, is a widely distributed bioflavonoid in the grapefruit and citrus peel, and it has already been reported as an antioxidant, antimicrobial, and anticancer agent. It has been used as a food preservatives and cosmetics. One of the natural preservatives, chitosan has also used in food preservatives, health drinks, and teas. Chitosan is distributed in the epithelium of crustacea, insects, and fungi. Naringin and chitosan have no harmful effects of cytotoxicity in the human body and they are recognized as an antibacterial for various forms of bacteria. The purpose of this study is to search for the ideal percentage of natural products to substitute the chemical preservatives occuring within the cornea and conjunctiva cytotoxicity and inflammations as wearing on soft contact lens. The present study compared the morphology of corneal epithelium and endothelium observed by light microscopy (LM) and transmission electron microscopy (TEM). In vivo methods, We investigated the effects of natural preservatives on soft contact lens. We inserted 3-4 drops of the naringin and chitosan, directly on rabbits' corneas 4 times per a day during one week. After enucleation of cornea, morphorgical damages of the epithelium and endothelium were observed by LM and TEM. In view of ultrastructure, chitosan caused siginficant damage on the epithelium and endothelium of cornea. The damage of cells was higher in chitosan treated cornea than 0.01, 0.1, and 1% of naringin. The 1% of naringin also expressed cell damage seriously. The results suggest that the most important thing is to use the reasonable percentage of preservatives for contact lens solutions.

  • PDF

Reliability of Measurements of Back Vertex Power for Soft Contact Lenses Using an Auto-Lensmeter (자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정 방법에 관한 신뢰도)

  • Kim, Kun-Kyu;Lee, Wook-Jin;Lee, Sun-Haeng;Kwak, Ho-Won;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Purpose: To assess the reliability for measuring the back vertex power of soft contact lenses by dry blotting and wet cell method using an auto-lensmeter. Methods: The soft contact lenses used for measurement were 5 types that were distributed in Korea, and 4 back vertex powers (-1.50D, -3.00D, -6.00D, -9.00D) were used. and repeatability and reproducibility were evaluated by measuring them with an auto-lensmeter by two examiners. Results: Measured powers by dry blotting method were ranged in mean differences from 0.03D to 0.18D for overall lenses, 0.10D to 0.18D for silicone hydrogel lenses, 0.03D to 0.08D for hydrogel lenses. The mean differences between two examiners were less than 0.10D, and the inter-examiner reproducibility was good for dry blotting method. The mean difference between powers determined by wet cell method were 0.09D to 0.69D, the mean differences between two examiners were 0.02D to 0.59D. The reliability of measurements and inter-examiner reproducibility were less than dry blotting method. Conclusions: The reliability of measurements for all materials was better in dry blotting than wet cell method, the re liability of measurements for silicone hydrogel lenses was low in both methods. In clinical practical which requires quick checking of back vertex power using an auto-lensmeter. dry blotting method is thought to be more efficient than wet cell one.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

Changes in Drug Elution Concentration and Physical Characteristics of Soft Contact Lenses Depending on the Initiator and Crosslinker (개시제와 교차결합제 농도의 변화에 따른 소프트콘택트렌즈의 물리적 성질과 약물용출 농도의 변화)

  • Park, Hyun-Ju;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Purpose: The material properties of contact lenses were measured by varying the amounts of an initiator and a cross-linking agent that are the basis for the manufacture of contact lenses, and the drug delivery effects depending on the material properties of contact lenses were compared. Methods: Contact lens samples were manufactured using HEMA by varying the concentration of the cross-linking agent and the initiator. To investigate the changes in physical characteristics depending on the material properties, the results of the experiments on the amount of drug elution, water content, refractive index, and the amount of protein adsorption were compared. Results: For the contact lenses manufactured by varying the amount of the initiator, the water content hardly changed, and the refractive index also hardly changed. The amount of drug elution was not much affected by the changes in the initiator, but the amount of elution increased as the water content increased. The amount of protein adsorption was hardly affected by the changes in the initiator, but the amount of adsorption increased as the water content decreased. Conclusions: The changes in the properties were hardly affected by the changes in the amount of the initiator, but were significantly affected by the changes in the amount of the cross-linking agent. As the amount of the cross-linking agent increased, the water content decreased, while the refractive index increased. Also, when the water content increased, the amount of drug elution increased, while the amount of protein adsorption decreased.

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

A Study on the Performance of Atomic Force Probe for Coordinate Measuring Machines (3차원 측정기를 위한 원자간력 프로브 성능 연구)

  • Jung, P.G.;Bae, G.H.;Hong, S.W.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents an atomic force probe for triggering coordinate measuring machines(CMMs). A rigorous comparison is made between touch trigger probe and atomic force probe for CMMs. Typical CMMs(touch trigger probe based CMMs) often lead to some errors associated with object curvature and difference in triggering sensitivity. Their applicability is limited only to hard objects. The aim of this work is to develop a trigger sensor for CMMs using atomic force. In order to show the applicability of atomic force as a trigger sensor, a cylindrical shape is measured with a CMM and an atomic force microscope. Three different touch probe heads with different ball sizes are tested. The experiments show that smaller ball provides better results for curved objects. The experimental results also show that the performance of atomic force as a trigger sensor is about that of the smallest ball probe. In addition, experiments are also performed to measure soft objects. Finally, this paper suggests and verifies a trigger sensor using atomic force for CMMs.

Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

Study on the Polymerization of Hydrogel Polymer Containing HEMA and Measurement Method of Oxygen Transmissibility (HEMA를 포함한 친수성 폴리머 중합 및 산소 투과율 측정 방법에 관한 연구)

  • Kim , Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.749-754
    • /
    • 2009
  • HEMA (2-hydroxyethyl methacrylate) is a hydrophilic material which is broadly used for ophthalmologic purposes and especially in the manufacture of soft contact lenses. Also, the oxygen transmissibility (Dk/t) is a very important physical characteristic in the evaluation of a material’s adequacy to be used to produce contact lenses. This study used HEMA (2-hydroxyethyl methacrylate), MMA (methylmethacrylate), NVP (Nvinyl-pyrrolidone), the cross-linker EGDMA (ethylene glycol dimethacrylate) for copolymerization, and measured the oxygen transmissibility of the central and peripheral areas of the manufactured general and color contact lenses using the polarographic method. The measurement showed that the decreased amount of oxygen transmissibility of the central and peripheral areas of the contact lenses measured using the polarographic method range between 40.77% and 49.13%, and the oxygen transmissibility of the color contact lens showed a larger decrease due to the effects of the coloring materials.

Opto-Physical Properties of Ophthalmic Lens Polymer Containing σ, m, p-Substituted Difluoroaniline as Additives (σ, m, p-위치로 치환된 Difluoroaniline을 첨가제로 사용한 안의료용 렌즈 고분자의 물리·광학적 특성)

  • No, Jung-Won;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.69-77
    • /
    • 2014
  • Purpose: The functional ophthalmic lenses containing fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were manufactured and the physical and optical characteristics of copolymerized ophthalmic lens were investigated. Methods: HEMA (2-hydroxyethylmethacrylate), NVP (N-vinyl pyrrolidone), MA (methacrylic acid), the cross-linker EGDMA (ethylene glycol dimethacrylate) and the initiator AIBN (azobisisobutyronitrile) were used as a basic combination and fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were used as additives for preparing the hydrogel soft contact lenses. The hydrogel ophthalmic lens was manufactured by cast mould method and the ophthalmic lenses were stored in a 0.9% NaCl normal saline for 24 hrs. Results: The optical transmittance of the sample with addition 2,4-difluoroaniline showed that the UV-B(9.8~51.4%), UV-A(58.8~79.2%) and visible transmittance(87.0~90.4%). In the case of 2,6-difluoroaniline were measured the UV-B(80.2~83.2%), UV-A(85.8~86.4%), and visible transmittance(90.8~91.4%). Also, the optical transmittance of ophthalmic lens containing 3,4-difluoroaniline were measured the UV-B transmittance of 3.8~30.4%, UV-A transmittance of 47.8%~74.4% and the visible transmittance of 86.2~91.0% respectively. Conclusions: Based on the results of this study, 2,4-difluoroaniline and 3,4-difluoroaniline can be used effectively as additive for UV-blocking ophthalmic contact lenses.