• Title/Summary/Keyword: sodium hypochlorite solution

Search Result 113, Processing Time 0.028 seconds

IN VIVO EVALUATION OF ACCURACY OF TWO ELECTRONIC APEX LOCATORS (전자근관장 측정기의 정확도에 관한 연구)

  • Kim, Hee-Jung;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.289-299
    • /
    • 1996
  • It is necessary to measure the length of a root canal in order to attain a satisfactory prognosis after root canal therapy. There are several methods for determining root canal length, such as tactile sensation by the dental practitioner, the utilization of x-ray film, and electronic root canal measurement. Among these, the electrical measurement methods, in which the impedence between the oral mucous membrane and periodontal membrane is determined, have advantages of simplicity and accuracy. During root canal treatment, the root canal contains a solution of high electrical conductivity such as pus, blood, sodium hypochlorite and so on. Recently a new electronic root canal measurement device of frequency-dependent type has been developed, which is capable of measuring the length of root canal under moist conditions. Endex and Root ZX, which are frequency-dependent type, were evaluated for accuracy of measuring root canal length in vivo by stereomicroscope. The result were as follows ; 1. 82.5% of Endex and 87.5% of Root ZX measured in the range of ${\pm}0.5$ mm from the apical foramen and both showed 57.5 % in the range of 0.1 mm to 0.5 mm. 2. Endex showed significantly higher accuracy in vital teeth than nonvital teeth(p<0.05). But in case of Root ZX, there was no significant difference between vital and nonvital teeth. 3. As a result of this study, there was no significant difference in accuracy between Endex and Root ZX, and both devices showed file passes the apical foramen in more than half of the cases, and it is thought that this must be considered clinically.

  • PDF

Interspecific Hybridization between Populus caspica L. × P. deltoids L 62/154 Using in vitro Embryo Development and Germination

  • Ali, Jafari mofidabadi;Mansooreh, Kamandloo;Hamid, Selamti
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • Populus. caspica L. is an Iranian indigenous poplar species which naturally distributed in the northern part of country. Unfortunately, overuse has removed many of the stems of better form, so that natural stands now usually appear small and crook. Therefore genetic variation for selection of new superior clone of this species is needed. Conventional hybridization system is currently used to induce genetic variation in poplar species but incompatibility barriers have been observed between them. In vitro ovule embryo culture was used to overcome incompatibility obstacle for interspecific hybridization between Populus caspica L. with Populus deltoids L.62/75. Female flowers of Populus caspica L. have artificially been pollinated with pollen grain of P. deltoides 62/75 in one direction using twig and pot crossing system. Ovaries at different ages (7, 14 and 21 days after pollination) were disinfected through 70% ethanol for 1 minute, 5% of sodium-hypochlorite solution for fifteen min followed by three time rising with sterile distil-water. Isolated ovaries were then transferred to MS hormone free medium containing 30 and 60 g/L sucrose for embryo development and germination. Collected data have been analyzed by two factorial experimental designs. The results indicated that there were significant differences between age of embryos for development and germination at ${\alpha}=0.01%$. Highest embryo germination (45%) was observed from 21 days old ovaries. No significant differences were observed between MS culture media containing 30 and 60 g/L for percentages of ovary-embryo germination and number of germinated embryo per ovary at ${\alpha}=0.05%$. Fourteen percentage of embryo germination obtained in MS medium supplemented with 60 g/L sucrose, while only 35% of isolated ovaries were able to germinate in MS containing 30 g/L sucrose. Induced plantlets in 4 cm height were transferred into pots containing soilless (1:1:1 peat, per lit and vermiculite) medium for acclimatization. After successful acclimatization, plants were delivered to nursery.

The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement

  • Tuncdemir, Ali Riza;Yildirim, Cihan;Ozcan, Erhan;Polat, Serdar
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.457-463
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P> .05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.

The use of auxiliary devices during irrigation to increase the cleaning ability of a chelating agent

  • Prado, Marina Carvalho;Leal, Fernanda;Simao, Renata Antoun;Gusman, Heloisa;do Prado, Maira
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.105-110
    • /
    • 2017
  • Objectives: This study investigated the cleaning ability of ultrasonically activated irrigation (UAI) and a novel activation system with reciprocating motion (EC, EasyClean, Easy Equipamentos $Odontol\acute{o}gicos$) when used with a relatively new chelating agent (QMix, Dentsply). In addition, the effect of QMix solution when used for a shorter (1 minute) and a longer application time (3 minutes) was investigated. Materials and Methods: Fifty permanent human teeth were prepared with K3 rotary system and 6% sodium hypochlorite. Samples were randomly assigned to five groups (n = 10) according to the final irrigation protocol: G1, negative control (distilled water); G2, positive control (QMix 1 minute); G3, QMix 1 minute/UAI; G4, QMix 1 minute/EC; G5, QMix 3 minutes. Subsequently the teeth were prepared and three photomicrographs were obtained in each root third of root walls, by scanning electron microscopy. Two blinded and pre-calibrated examiners evaluated the images using a four-category scoring system. Data were statistically analyzed using Kruskal-Wallis and Dunn tests (p < 0.05). Results: There were differences among groups (p < 0.05). UAI showed better cleaning ability than EC (p < 0.05). There were improvements when QMix was used with auxiliary devices in comparison with conventional irrigation (p < 0.05). Conventional irrigation for 3 minutes presented significantly better results than its use for 1 minute (p < 0.05). Conclusions: QMix should be used for 1 minute when it is used with UAI, since this final irrigation protocol showed the best performance and also allowed clinical optimization of this procedure.

Elution of calcium ion from calcium hydroxide products using various root canal irrigants (수종의 관주용액의 수산화칼슘제재에 대한 칼슘 용출효과)

  • Seo, Jung-Hwa;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.379-390
    • /
    • 1998
  • In endodontic treatment, calcium hydroxide has been used as intracanal medicament. Although calcium hydroxide should be removed thoroughly before permanent root canal filling, no effective method for its removal has been reported. Because of irregularity of root canal walls, root curvatures and anatomic variations, it is insufficient to remove calcium hydroxide from the canal wall only by mechanical instrumentation Considering the chemical effects of irrigants on calcium hydroxide, $Ca^{++}$ dissolving effect from two calcium hydroxide products is investigated, using dis- tilled water, NaOCl, citric acid and EDTA. Vitapex$^{(R)}$ 0.1g and calcium hydroxide 0.03g were dissolved in distilled water, 5% NaOCl, 50% citric acid and 17% EDTA respectively, at 1, 3, 5, 10min. time interval. The solution was filtered using filter paper(pore size $5{\mu}m$) and $Ca^{++}$ concentration was determined by ion chromatography. The result were as follows : 1. Distilled water, NaOCl, citric acid and EDTA abstracted more $Ca^{++}$ from calcium hydroxide than Vitapex$^{(R)}$ except NaOCl 1, 5, 10 time interval. 2. EDTA and citric acid abstracted more $Ca^{++}$ from Vitapex$^{(R)}$ and calcium hydroxide than distilled water or NaOCl. The overall result support the view that water-based calcium hydroxide product is easily removed than oil-based calcium hydroxide product and EDTA, citric acid are more effective in $Ca^{++}$ elution than NaOCl or distilled water.

  • PDF

Isolation of Chitin from Crab Shell Waste (게 가공 폐기물로부터 키틴의 분리)

  • 노홍균;이문이
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.1
    • /
    • pp.105-113
    • /
    • 1995
  • Procedures for isolatin of chitin have been developed from crab(Chionoecetes opilio) shell waste with 26. 65% chitin on a dry basis. Optimal conditions for demineralization of crab shell were 1N HCl at ambient temperature for 30min with a solids to solbent ratio of 1 : 15(w/v). Optimal deproteinization involved treatment with 5% NaOH at $65^{\circ}C$ for 1 hr with a solids to solvent ratio of 1 : 15(w/v). Effective decoloration was achieved by bleaching with 0.32% sodium hypochlorite solution for 3min with a solids to solvent ratio of 1 : 10(w/v). Particular attentin was given to characterization of the physicochemical properties of the crab chitin. Chitins, from four different mesh sizes of crab shell, did not show significant differences in nitrogen and ash compositions. Bleaching decreased the viscosity of chitin but did not affect its solubility.

  • PDF

Ceramic based Nanofiltration Membrane for Wastewater Treatment: A Review (폐수처리를 위한 세라믹계 나노여과막: 리뷰)

  • Yeonsoo, Kwak;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.390-400
    • /
    • 2022
  • Nanofiltration (NF) membranes are more popular than reverse osmosis (RO) membranes as they can be operated at much lower pressures for applications in treatment of wastewater from industries like food processing and pharmaceutical as well as municipal sewage water. The separation mechanism in case of NF membranes is based on solution diffusion as well as sieving, for which the crosslinking density of the thin film of the composite membrane is less then RO membrane. Unlike ceramic membranes, membrane fouling is one of the chronic problems that occur during the nanofiltration process in polymeric membranes. Membrane cleaning is done to get rid of reversible as well as irreversible fouling by treatment with sodium hypochlorite. Compared to polymeric membranes, ceramic membranes show higher stability against these agents. In this review different types of ceramic membrane applied wastewater treatment by NF process are discussed.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

Resin infiltrant protects deproteinized dentin against erosive and abrasive wear

  • Ana Theresa Queiroz de Albuquerque;Bruna Oliveira Bezerra;Isabelly de Carvalho Leal;Maria Denise Rodrigues de Moraes;Mary Anne S. Melo;Vanara Florencio Passos
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.3
    • /
    • pp.29.1-29.10
    • /
    • 2022
  • Objectives: This study aimed to investigate the anti-erosive/abrasive effect of resin infiltration of previous deproteinized dentin. Materials and Methods: Dentin slabs were randomly assigned to 3 groups (n = 15): Control (no deproteinization; no resin infiltrant applied), RI (no deproteinization; resin infiltrant applied), and DRI (deproteinization; resin infiltrant applied). After undergoing the assigned treatment, all slabs were subjected to an in vitro cycling model for 5 days. The specimens were immersed in citric acid (0.05 M, pH = 3.75; 60 seconds; 3 times/day) and brushed (150 strokes). Between the challenges, the specimens were exposed to a remineralizing solution (60 minutes). The morphological alterations were analyzed by mechanical profilometry (㎛) and scanning electron microscopy (SEM). Data were submitted to one-way analysis of variance (ANOVA) and Tukey tests (p < 0.05). Results: Control and RI groups presented mineral wear and did not significantly differ from each other (p = 0.063). DRI maintained a protective layer preserving the dentin (p < 0.001). After erosive/abrasive cycles, it was observed that in group RI, only 25% of the slabs partially evidenced the presence of the infiltrating, while, in the DRI group, 80% of the slabs presented the treated surface entirely covered by a resin-component layer protecting the dentin surface as observed in SEM images. Conclusions: The removal of the organic content allows the resin infiltrant to efficiently protect the dentin surface against erosive/abrasive lesions.

Influence of Sodium Hypochorite & EDTA on the Microtensile Bond Strength of Ethanol Wet Bonding (Ethanol Wet Bonding에서 NaOCl과 EDTA가 결합강도에 미치는 영향)

  • Kim, Deok-Joong;Song, Yong-Beom;Park, Sang-Hee;Kim, Hyoung-Sun;Lee, Hye-Yoon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • Sodium hypochlorite and ethylene diamine tetra acetic acid are substances usually used during endodontic treatment. Several studies found that the bonding was negated with certain irrigants and some of the used irrigants have demineralizing and chealating effects, so it was advocated to omit the etching step in etch and rinse adhesive systems. The purpose of this in vitro study was to evaluate the influence of NaOCl & EDTA on the bonding strength of ethanol wet bonding. Thirty human molars were selected and mesiodistally sectioned into halves, thus providing sixty specimens. The specimens were randomly assigned to 4 groups(n=15) according to the irrigant regimen used : (1) irrigated with distilled water for 10min (control); (2) irrigated with 5.25% NaOCl(10min), flushed with 5.25% NaOCl(1min) (3) irrigated with 5.25% NaOCl, flushed with 17% EDTA (4) irrigated with 5.25% NaOCl, flushed with 17% EDTA. Each group was acid-etched with 37% phosphoric acid(except group 4) and had their dentin surfaces dehydrated with ethanol solutions : 50%, 70%, 80%, 95%, 3x100%, 30s for each application. After dehydration, a primer( 50% all bond 3 resin + 50% ethanol) was used, followed by the adhesive(ALL-BOND 3 RESIN) application. Resin composite build-ups were then prepared using an incremental technique. Specimens were sectioned into beams and submitted to a tensile load using a Micro Tensile Tester(Bisco Inc.). The data were statistically analyzed using one-way ANOVA and Tukey HSD at p<0.5 level. There was no significant difference on G1(control) and G2(irrigated with NaOCl only ). (p>0.05). G3(flushed with EDTA) showed significantly high tensile bonding strength compared to the G2 (p<0.05). G4( treated with EDTA but no acid-etching) was significantly lower value than G3. (p<0.05) Although there was no significant difference, 5.25% NaOCl seemed to have an adverse effect on the bonding strength of ethanol wet bonding. The flushing with EDTA after NaOCl irrigation prevents the decrease of bonding strength. The use of 17% EDTA as a final flush can enhance the bonding strength but EDTA flushing can't substitute for a acid-etching.