내설성 향상을 위한 지붕형 조립식 파이프하우스의 개발 (Development of a Gable-roofed Prefabricated Pipe-house for Improvement of Snow Endurance)

  • 양인규;남상운
    • 한국농공학회논문집
    • /
    • 제51권3호
    • /
    • pp.71-78
    • /
    • 2009
  • Pipe section of bending part at the arch type pipe-house showed an ellipse with oblateness of 0.076 on the average. Flexural rigidity of bending part decreased by average 6.3% than that of an original round shape section. The deflection of arch type pipe-house measured by model experiments showed much bigger than the result of structural analysis. In case of arch type pipe-house, we supposed that the decrease of flexural rigidity for the bending part of pipes had an effect on deflection of roof under the working load. This effect should be considered in the structural analysis. Bending resistance of gable type pipe-house used a prefabricated connector which developed in this study showed about $1.5{\sim}1.8$ times stronger than that of the existing arch type or gable type processed bending. Therefore, we supposed that the gable-roofed prefabricated pipe-house is safer than arch type or bent gable type in case of heavy snowfall. According to house scales and section properties of steel pipe in use, safe snow depths and rafter intervals were presented for design of gable-roofed prefabricated pipe-house. Their standards were established in the range of the durable models recommended by RDA, and the comparative examinations were conducted by means of structural analysis. It was evaluated that the developed greenhouse model had a high applicability in the field.

지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 박진상;강효진;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

성주지역 참외 재배용 온실구조 현황 및 모델 개발 (Current Status and Development of Greenhouse Models for Oriental Melon Cultivation in Seongju Region)

  • 이종원;백철현;이현우;정성원
    • 생물환경조절학회지
    • /
    • 제23권2호
    • /
    • pp.95-108
    • /
    • 2014
  • 본 연구는 성주지역에 적합한 참외재배용 내재해형 온실을 개발하기 위하여 참외 재배온실의 구조현황 조사, 최근 기상자료가 반영된 설계하중 산정, 온실모델 설정 및 구조안전성 분석을 수행하였으며 결과를 요약하면 다음과 같다. 성주지역 참외온실의 구조적 특성을 파악하기 위하여 현장 조사한 결과, 온실의 지붕형상은 아치형이 가장 많았으며, 최근에 시공한 온실일수록 복숭아형이 많았으며 폭이 넓어지고 동고도 높아지는 추세였다. 그리고 성주지역에 가장 인접한 구미기상대의 기상자료를 이용하여 재현기간에 따른 설계풍속 및 설계적설심을 산정할 수 있는 계산식을 유도하였으며, 내재해형 온실규격을 만족하는 재현기간 30년의 적설심은 23.7cm, 풍속은 $33.8m{\cdot}s^1$로 계산되었다. 이러한 성주지역의 내재해형 설계기준을 만족하는 참외재배용 단동온실 4종, 2연동온실 및 연결온실을 각각 1종씩 총 6종의 모델을 개발하였다.

온실의 유지관리 실태조사 분석 (Field Survey on the Maintenance Status of Greenhouses in Korea)

  • 최만권;윤성욱;김현태;이시영;윤용철
    • 생물환경조절학회지
    • /
    • 제23권2호
    • /
    • pp.148-157
    • /
    • 2014
  • 본 연구는 농가들의 온실 유지관리 실태를 알아보기 위해서 국내에 보급되어 있는 온실에 대해 전국을 대상으로 온실규격, 자연재해 예방 및 피해상황, 온실 구조재, 온실 피복재 등에 관한 실태를 조사하여 자료를 분석하였다. 그 결과를 요약하면 다음과 같다. 온실의 규격의 경우, 길이는 단동 및 연동 온실 모두 90m이상이 가장 많았다. 폭은 단동온실 및 연동 온실이 각각 8m이상 및 7.0~7.9m, 측고 1.5~1.9m 및 2.0~2.9m, 동고 3.0~3.9m 및 6m가 가장 높은 비율을 차지하는 것으로 나타났다. 내재해형 온실을 조사한 결과 농가에서 내재해형 온실 설치를 기피하는 것으로 조사되었다. 온실의 자연재해 피해는 대설 보다 태풍에 대한 피해를 많이 받는 것으로 조사되었다. 자연재해 예보 시 점검사항의 경우, 태풍 예보가 있을 때에는 천창, 측창, 출입문 및 피복재 고정밴드를 주로 점검하며, 대설 예보가 있을 때에는 난방기를 주로 점검하는 것으로 나타났다. 온실파이프에 부식이 발생 시 보수방법은 도색 보다는 부분적인 교체를 많이 하고, 자연재해 예방을 위한 구조물의 보강재를 대부분 사용하지 않는 것으로 나타났다. 온실 피복재의 유지관리는 대부분의 농가에서 피복재 밀폐성을 점검하는 것으로 나타났지만, 광 투과를 위한 피복재의 청소는 대부분 하지 않는 것으로 나타났다. 태풍시 온실 피복재를 제거하면 구조재 파괴를 막을 수 있는데 그렇게 못하는 이유는 피복재의 교체비용, 재배작물 때문인 것으로 파악되었다. 그리고 온실농가에서 화재예방을 위한 소방설비 구비 여부에 대해 조사한 결과, 온실의 화재예방 인식이 많이 부족한 것으로 나타났다.