• 제목/요약/키워드: smooth tube

검색결과 223건 처리시간 0.024초

말초신경 결손시 신경도관으로서 Gore-Tex® 도관의 유용성 (The Availability of Gore-Tex® Tube as Nerve Conduit at the Peripheral Nerve Defect)

  • 이기호;오상하;이승렬;강낙헌
    • Archives of Plastic Surgery
    • /
    • 제32권5호
    • /
    • pp.613-618
    • /
    • 2005
  • When a large peripheral nerve defect occurs, an autologous nerve graft is the most ideal method of recinstruction. But an autologous nerve graft has many limitations due to donor site morbidities. Many previous focused on finding the ideal nerve conduit. Among them, $Gore-Tex^{(R)}$ has several advantages over other conduits. It can be manipulated to a suitable size, does not collapse easily, and it is a semi- permeable material that contain pores. A round shaped nerve can be newly formed because of its smooth inner surface. The purpose of this study was to evaluate the availability of $Gore-Tex^{(R)}$ tube as a nerve conduit at the peripheral nerve defect in the rat sciatic nerve. The 10 mm nerve gap was made in each group. A $Gore-Tex^{(R)}$ tube filled with skeletal muscle was inserted and autologous nerve graft was harvested, respectively. In the experimental group, we placed a 0.5 mm thickness, $30{\mu}m$ pored, 1.8 mm in diameter and 14 mm length tube with skeletal muscle inserted inside. In the control group, the nerve gap was inserted with a rat sciatic nerve. We estimated the results electrophysiologically and histologically to 16 weeks postoperatively. Results in the nerve conduction velocity, total myelinated axon count, myelin sheath thickness and mean nerve fiber diameter, the experimental group was substantially lower than that of the control group, but the statistic difference was not significant (p<0.05). The morphology was very similar in both groups, microscopically. From the above results, We conclude that $Gore-Tex^{(R)}$ qualifies as an ideal nerve conduit. It is suggested that $Gore-Tex^{(R)}$ tube filled with skeletal muscle may, substitute for an autologous nerve graft.

부드러운 $C^2$확장 곡면 생성 (The Generation of a Smooth C Extension Surface)

  • 김회섭
    • 한국CDE학회논문집
    • /
    • 제9권2호
    • /
    • pp.143-147
    • /
    • 2004
  • To design parts satisfying physical property in the continuous region, we do it in the discrete rectangular mesh points. Then we obtain points data from parts design and usually construct the surface using least squares method. In such case, that surface has an oscillation in the ineffective region which is inadequate for physical phenomena or NC machining. To solve both problems simultaneously, we extend the surface smoothly to have small curvature in the extended region. Up to now, we use the least squares method for the parts design in Color Picture Tube or Color Display Tube but in this paper, we use functions which is easily controllable. This surface has no error within the effective region compared to the least squares method.

LiBr 수용액의 수평관 유하액막 증발에 있어서의 열전달계수 특성 (The characteristics of heat transfer coefficient for falling-film evaporation on a horizontal tube with aqueous LiBr solution)

  • 지용해;김동관김무환
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.294-302
    • /
    • 1997
  • Falling-film evaporation experiments for aqueous solution of lithium bromide (LiBr) were performed on a horizontal smooth 19.05-mm-dia copper tube. Average heat transfer coefficients were obtained with varied film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. Heat transfer coefficients increase with increasing system pressure and decreasing concentration. For degrees of wall superheat, the heat transfer coefficient did not't show the distinct trend. For this experimental ranges, heat transfer coefficients showed maximum values at an optimal film Reynolds number. The results of this work were compared with pool boiling data reported previously, and it was shown that the heat transfer performance is superior to the pool boiling.

마이크로휜관 내 단상 냉각 유동 열전달 및 압력 강하 특성에 관한 실험적 연구 (Experiments on Single Phase Cooling Heat Transfer and Pressure Drop Characteristics in Microfin Tubes)

  • 이규정;한동혁
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.231-239
    • /
    • 2002
  • Experiments on the single phase cooling heat transfer and pressure drop with microfin tubes were performed using water as a test fluid. Experimental data were obtained in the range of Reynolds number 3000 ~40000 and Prandtl number 4-6. The data of microfin tubes presented the characteristics of rough surface tube in pressure drop and heat transfer Experimental data were compared with the heat transfer and friction factor correlations of smooth tubes. Heat transfer enhancements of microfin tubes were lower than pressure drop penalty factors. The helix angle is more significant parameter in both of the pressure drop and heat transfer than the relative roughness. The correlations of Nusselt number and friction factor were suggested for the tested microfin tubes. Maximum deviations between correlations and experimental data were within $\pm15$% for Nusselt number and $\pm10$% for friction factor.

세관 내 R-718의 단상 열전달 및 압력강하 특성에 관한 연구 (Study on the Single-Phase Heat Transfer and Pressure Drop Characteristics of R-718 in Small Diameter Tubes)

  • 박기원;권옥배;홍진우;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.522-530
    • /
    • 2004
  • Single-phase heat transfer coefficients and pressure drops of R-718 were measured in smooth, horizontal copper tubes with inner diameters of 3.36 ㎜, 5.35 ㎜. 6.54 ㎜ and 8.12 ㎜, respectively. The experiments were conducted in the closed loop, which was driven by a magnetic gear pump. Data are presented for the following range of variables : Reynolds from 1000 to 20000. Single-phase heat transfer coefficients increased by 10∼30 % as the inner diameter of tube was reduced and it was found that a well-known previous correlation, Gnielinski's correlation was not suitable for the small diameter tubes. But the pressure drop in the small diameter tubes have been shown slightly deviations with Blauius' correlation. Based on an analogy between heat and mass transfer. the new heat transfer correlation is proposed to predict the experimental data successfully.

수평평활관내 탄화수소계 냉매의 응축전열 특성에 관한 연구 (Condensation heat transfer characteristics of hydrocarbon. refrigerants inside horizontal tubes)

  • 이용언;박승준;정진호;장승환;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.15-20
    • /
    • 2001
  • This study investigated the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube. Heat transfer measurements were peformed for smooth tube with outside diameter of 12.7 mm Condensation temperatures and mass velocity were ranged from 308 K to 323 K and $51kg/\textrm{m}^2s$s to $250kg/\textrm{m}^2s$, respectively. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effects of mass velocity on heat transfer coefficients of R-290 and R-600a were less than R-22. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Haraguchi's correlation.

  • PDF

Evaluation of Condensation Heat Transfer Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.163-168
    • /
    • 2007
  • The feature of six existing condensation heat transfer correlations for microfin tubes were evaluated with the consideration of vapor quality, mass flux, geometries, and various refrigerants. The Kosky and Staub [15] and the Jaster and Kosky [16] correlations for smooth tube were used for the evaluation of the heat transfer enhancement factor (EF). For the prediction of zeotropic mixtures, most correlations show discrepancy with previous measurements. The Yu and Koyama [4] and the Shikazono et al. [8] correlations do not consider spiral angle effect. The Han and Lee [10] correlation shows fin height growth deteriorates heat transfer. Experimental verification to develop reliable condensation heat transfer correlation for microfin tubes is still needed with the consideration of geometrical effects and working conditions.

HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달 (Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube)

  • 오종택;비원 영치
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.