• Title/Summary/Keyword: smoke exhaust rate

Search Result 75, Processing Time 0.023 seconds

A Study of Smoke Exhaust Rate for the Transverse Ventilation with Oversized Exhaust Ports in Road Tunnel (횡류식 대배기구 방식을 적용한 도로터널에서 화재시 최적배연풍량 선정에 관한 연구)

  • Yoo, Ji-Oh;Yoon, Sung-Wook;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.7-12
    • /
    • 2006
  • Recently, the application of transverse ventilation system with oversized exhaust ports has been increased in bidirectional road tunnel in order to improve smoke exhaust ability. Therefore, in this study, for decision of the optimal smoke exhaust rates in the transverse ventilation system, several standards of nations are compared and numerical simulations with variations of exhaust flow rates are carried out in terms of smoke spread distance by FDS ver. 3.1. As results, in the case of no internal longitudinal air velocity in tunnel, the smoke exhaust rate of $80m^{3}/s$ (the smoke generation rate at HRR of 20MW) is sufficient enough to limit the smoke spread within 250m in 6 minutes after the fire. However, in the case of the internal longitudinal air velocity at 2.5m/s, the smoke exhaust rate should be increased $130m^{3}/s$.

A Study on Setting Smoke Exhaust Rate According to the Transverse Ventilation with Oversized Exhaust Ports in Road Tunnel by the Variation of Fire Intensity (화재강도변화에 따른 횡류식 대배기구 배연량 설정에 관한 연구)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.38-43
    • /
    • 2008
  • Recently, the application of transverse ventilation system in accordance with oversized exhaust ports has been increased in bidirectional road tunnel in order to improving smoke exhaust ability. In this study, numerical simulations were carried out by using FDS (ver. 4.0) which includes variations of exhaust flow rates and heat release rate of fire to obtain the optimal smoke exhaust rate in case of fire in the transversely ventilation system. As a result, smoke exhaust amount tends to increase when the inner velocity is existing in the tunnel. In case of internal longitudinal air velocity 2.5m/s face to the fire, smoke moving distance should be restricted within 250m when the smoke exhaust rate which exceeds $244.8m^3/s$.

Numerical Study on the Definition of the Exhaust Effectiveness of Smoke under Fire in a Large Space (대공간 화재시 배연효율 정의에 관한 수치해석적 연구)

  • Kim, Jung-Yup;Jang, Kyung Jin;Han, Hwataik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.535-540
    • /
    • 2014
  • This paper investigates the exhaust effectiveness of smoke, in the case of fire in a large atrium space. Numerical analysis was conducted to simulate transient fire growth in a test room, modeled by the Murcia atrium fire test. Various indices representing the exhaust performance of the exhaust system were obtained, such as the height of the smoke layer, and the instantaneous and accumulative capture efficiency of the smoke. The residual life time of smoke from the fire was also obtained, by injecting tracer gases at the fire location, depending on the airflow rate, and the location of the exhausts. The capture efficiency based on smoke concentration at the exhausts exhibits how much smoke can be removed by the exhaust system; whereas, the exhaust effectiveness based on residual life time indicates how rapidly the smoke can reach the exhaust locations, before being exhausted. The definitions and meanings of the indices to be used in representing the exhaust performance of a smoke exhaust system installed in a large space are discussed.

Comparison of Two Different Smoke Extraction Schemes of Transversely Ventilated Tunnel Fire

  • Rie, Dong-Ho;Kim, Hyung-Taek;Yoo, Ji-Oh;Shin, Hyun-Jun;Yoon, Sung-Wook
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.30-35
    • /
    • 2005
  • In case of tunnel fire, one of the most effective facilities to save lives is the smoke control system. In this study, two different smoke extraction schemes of transversely ventilated tunnel were compared. One is the smoke extraction using the fixed exhaust ports on the false ceiling to achieve the uniform and distributed smoke extraction (uniform exhaust). The other is that using the remote controlled smoke extraction where only vents close to the fire is opened whereas the others are closed to enhance the limitation of the smoke spread (localized exhaust). A number of numerical simulations were performed to find out the optimal smoke extraction rate at each smoke extraction scheme to allow the tunnel users to escape to the safe area without endangering their lives by smoke.

Factor Analysis on Exhaust Gas Emissions of Small DI Diesel Engine (직접분사식 소형 디젤엔진의 배기배출물에 대한 인자분석적 고찰)

  • JANG, Se-Ho;KIM, Yeong-Sik
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.586-592
    • /
    • 2017
  • This study analyzed the effect of four control factors, RPM, load, EGR rate and cooling water temperature on the exhaust emissions of the small DI diesel engine. The amount of NOx and smoke emissions were measured through experiments for three levels of four control factors according to orthogonal array table, and the effect of four factors on NOx and smoke emissions was analyzed quantitatively. The main results obtained in this study are summarized as follows: 1. RPM, load and EGR rate have a great influence on NOx and smoke emissions, and the effect of cooling water temperature is negligible. 2. As RPM and load increases NOx emission increases and decreases sharply as the EGR rate increases. 3. Smoke emission decreases or increases randomly according to RPM and load, but increases sharply in proportion to the EGR rate. 4. EGR rate has the greatest effect on NOx and smoke emissions by more than 60% of contribution to variance, especially in the case of NOx emission, EGR rate represents a significant result even under the confidence level of 99% on ANOVA.

A Study on the Effective Fire and Smoke Control in Semi-Transverse Ventilation (균일배기 환기방식에서의 배연특성에 관한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Seo, Young-Ho;Yoo, Oh-Ji;Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.90-94
    • /
    • 2010
  • In this study it is intended to review the moving characteristics of smoke by performing visualization simulation for the calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. If the wind velocity is in the tunnel, the exhaust rate intends to increase rapidly and the exhaust efficiency is decreased. In addition, if the wind velocity is increased, the exhaust rate should be increased in compared with the generation rate of smoke in maximum 1.8 or 1.04 times. In this study, when the wind velocity is in the tunnel, the limited exhaust rate is $84m^3/s{\cdot}250m$. And if it was assumed 1.75 m/s critical velocity in the tunnel, the exhaust rate would be defined $393m^3/s{\cdot}250m$($Q_E$ = 80 + 5Ar).

An experimental study on exhaust gas variation depending on EGR rate of common rail engine (커먼레일엔진 EGR RATE에 따른 배기가스 변화에 대한 실험적 연구)

  • Kim, Jin-Yong;Na, Byung-Chul;Lee, Kye-Cheul;Seo, Joon-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2167-2172
    • /
    • 2004
  • Current common rail engines are equipped with cooled EGR systems by using an engine cooling water system. In this study, investigations of exhaust gas reduction characteristics have been carried out in the common rail engine system depending on the EGR rate variation. The experimental results shows that NOx reduces and smoke increases as the EGR rate increases.

  • PDF

Effect of Impinging Plate on Exhaust Emission and Engine Performance in Diesel Engine

  • Jin, Yong-Su;Kim, Jae-Dong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.82-88
    • /
    • 2015
  • The purpose of this study is to investigate the effect of the impinging plate on combustion process in Diesel engine. Especially, the variation of exhaust emission and engine performance by the change of fuel injection timing and fuel injection pressure between the trial engine with impinging plate and the prototype engine were examined. The nitrogen oxide concentration of the trial engine decreased more than 50% compared to the prototype engine, however, smoke concentration of the trial engine indicated higher degree than the prototype engine. The smoke concentration, fuel consumption rate and exhaust gas temperature decreased as the fuel injection timing become faster, whereas the nitrogen oxide concentration decreased as the fuel injection timing is retarded. The nitrogen oxide concentration, fuel consumption rate and exhaust gas temperature decreased as the fuel injection pressure become lower. But smoke concentration decreased as the fuel injection pressure become higher.

CHARACTERISTICS OF PERFORMANCE AND EXHAUST EMISSION OF DIESEL ENGINES BY CHANGES IN FUEL PROPERTIES AND APPLICATION OF EGR

  • Choi, S.H.;Oh, Y.T.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.179-184
    • /
    • 2007
  • In this study, the potential use of oxygenated fuels such as ethylene glycol mono-normal butyl ether (EGBE) was investigated in an attempt to reduce the emission of exhaust smoke from diesel engines. Effects of the combustion method on exhaust emission of DI and IDI diesel engines were also examined. Since EGBE is composed of approximately 27.1% oxygen, this is one of several potential oxygenated fuels that could reduce the smoke content of exhaust gas. EGBE blended fuels have been proven to reduce smoke emission remarkably compared to the conventional commercial fuels. The test was conducted with single and four cylinder, four stroke, DI and IDI diesel engines. The study showed that a simultaneous reduction of smoke and NOx emission could be achieved by the combination of oxygenated blend fuels and the cooled EGR method in both DI and IDI diesel engines. It was also found that a reduction rate of exhaust emission in a DI engine was larger than an IDI diesel engine.

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.