• 제목/요약/키워드: smoke detector

검색결과 106건 처리시간 0.024초

W 대역 영상라디오미터 시스템 개발 (Development of an Imaging Radiometer System at W-band)

  • 정민규
    • 한국군사과학기술학회지
    • /
    • 제13권6호
    • /
    • pp.1133-1138
    • /
    • 2010
  • We have developed an imaging radiometer system at W-band. The system consists of lens, reflector, 30-ch receiver array, scanner, and signal processor. One receiver consists of a dielectric rod antenna, a balun, LNA(low noise amplifier) and a detector. The system configuration requirements are described. Finally, we represent radiometer images to obtain through clouds, smoke, dust, and other obstructions which render visible and IR systems ineffective.

국제우주정거장 내부 화재시 연기거동 및 감지특성에 관한 수치 모델링 (A Numerical Modeling of Smoke Behavior and Detection for Fire Developed in International Space Station)

  • 박설현;이주희;김연규;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.51-56
    • /
    • 2012
  • 국제우주정거장에서 화재발생은 승선한 승무원들의 생명과 직접적으로 연관된 사안이므로 선실내부에서 언제든지 발생할 수도 있는 화재의 초기 감지 및 진화는 우주정거장의 운영에 있어서 중요한 기술 중 하나이다. 본 연구에서는 국제우주정거장에서 각종 실험과 연구를 진행하는 가압모듈을 대상으로 환기, 연기거동 및 감지에 관한 수치모델링을 수행하였다. 수치모델링은 NIST에서 개발된 FDS(Fire Dynamic Simulator)를 사용하였으며, 부력이 작용하지 않는 국제우주정거장 내부의 무중력환경에서 발생된 화재의 연기거동패턴은 지상에서의 현상들과 큰 차이가 있음을 확인할 수 있었다. 아울러 가압모듈에서 적용되고 있는 환기조건을 고려하여 수행된 연기거동 및 감지특성에 대한 수치 모델링 결과는 향후 무중력환경에 노출된 수 있는 우주선이나 대형우주구조물의 화재검출장비의 설계를 위한 기초적인 자료를 제공함은 물론 승선하게될 우주인이나 승무원들의 훈련자료로도 유용하게 쓰일 수 있을 것으로 기대된다.

대규모 실내경기장의 소방방재설비 적용현황 분석 (A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium)

  • 최동호;김춘동;양정훈;조영흠
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.135-145
    • /
    • 2010
  • 본 논문은 사례조사를 통해 국내외 대규모 실내경기장의 소방방재계획상의 특정을 분석함으로서 향후 국내에 건립될 대공간 건축물의 소방방재계획 수립에 활용될 기초자료를 도출코자 하였다. 본 논문에서는 국내의 소방방재설비관련 법규 검토와 국내 3개, 국외 8개의 대규모 실내경기장을 대상으로 화재감지설비 소화설비 배연설비 피난계획 적용현황을 조사하여 대공간의 소방방재시스템의 동향을 파악하고 이들을 비교, 분석하였다. 연구 결과 대규모 실내경기장의 화재감지설비는 공간특성에 적합한 적외선화재감지기, 염감지기 등이 유력한 화재감지설비로 사용되며, 소화설비는 건식살수설비, 방수총소화설비 등이 채택되었으며 배연에서는 축연시스템이 적극 활용됨을 확인하였다.

  • PDF

도로터널용 방수노즐 위치제어형 자동소화설비의 화재감지성능실험 (Fire Detection Performance Experiment of the Water Jet Nozzle Position Control Type Automatic Fire Extinguishing Facility for Road Tunnels)

  • 김창용;공하성
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • 이 연구는 불꽃파장 감지기술과 불꽃영상 감지기술을 융합한 도로터널용 자동소화설비의 화재감지성능을 평가하기 위한 실험이다. 화재감지성능을 향상시키기 위한 이 융합기술은 화재 시 화원의 위치를 파악하고, 노즐을 화원으로 향하여 화재가 발생한 장소에만 가압수를 방사함으로서 화재진압에 따른 수손피해를 줄이는 효과를 얻을 수 있었다. 도로터널의 화재 중 불꽃 및 연기가 선행되는 상황에서 각각 15 m, 20 m, 25 m, 30 m, 35 m 거리에 $70cm{\times}70cm$의 목표물을 두었을 때 화원의 위치를 파악하는지를 실험하였다. 실험결과 농연의 간섭으로 인해 자외선 및 삼파장적외선센서의 감지능력이 감쇠되는 결과를 확인하였다. 또한 농연으로 인해 불꽃이 가려진 경우 이미지센서가 농연을 감지하여 화재신호를 발신함을 확인하였다.

다중가스센서를 이용한 화재의 조기검출에 대한 연구 (A Study on the Early Fire Detection by Using Multi-Gas Sensor)

  • 조시형;장향원;전진욱;최석임;김선규;강종위;최삼진;박찬원
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.342-348
    • /
    • 2014
  • This paper introduced a novel multi-gas sensor detector with simple signal processing algorithm. This device was evaluated by investigating the characteristics of combustible materials using fire-generated smell and smoke. Plural sensors including TGS821, TGS2442, and TGS260X were equipped to detect carbon monoxide, hydrogen gas, and gaseous air contaminants which exist in cigarette smoke, respectively. Signal processing algorithm based on the difference of response times in fire-generated gases was implemented with early and accurately fire detection from multiple gas sensing signals. All fire experiments were performed in a virtual fire chamber. The cigarette, cotton fiber, hair, polyester fiber, nylon fiber, paper, and bread were used as a combustible material. This analyzing software and sensor controlling algorithm were embedded into 8-bit micro-controller. Also the detected multiple gas sensor signals were simultaneously transferred to the personnel computer. The results showed that the air pollution detecting sensor could be used as an efficient sensor for a fire detector which showed high sensitivity in volatile organic compounds. The proposed detecting algorithm may give more information to us compared to the conventional method for determining a threshold value. A fire detecting device with a multi-sensor is likely to be a practical and commercial technology, which can be used for domestic and office environment as well as has a comparatively low cost and high efficiency compared to the conventional device.

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

화재감지기 신뢰성 검증방법에 관한 연구 (A Study on the Reliability Test for Smoke Detection Chamber of Smoke Detector)

  • 홍성호;최문수;박상태;유송현;유상필
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2013년도 춘계학술대회 초록집
    • /
    • pp.150-151
    • /
    • 2013
  • 화재감지기는 연기감지기는 이온전류의 변화량을 감지하는 이온화식 연기감지기와 발광부와 수광부로 이루어진 챔버내에 연기에 의한 광량의 변화를 감지하는 광전식 연기감지기로 구분된다. 국내에서는 광전식 연기감지기가 더 많이 사용되고 있는데 이러한 광전식 연기감지기의 챔버내에 이물질이 침입하게 되면 비화재보를 발생시키게 된다. 본 논문은 연기감지기의 연기감지 챔버에 대한 비화재보를 감소시키기 위한 신뢰성 시험에 대하여 논한 연구이다. 본 연구에서는 광전식 연기감지기의 신뢰성을 검증하는 방법으로 UL 268 등에 규정되어 있는 먼지, 즉, 분진에 대한 신뢰성을 검증방법을 제시하였다. 먼지에 대한 신뢰성 검증을 보다 적절하게 하기 위하여 분진챔버로 분진을 반복적으로 폭로됨에 따른 감도성능 변화를 분석하는 방법이 필요할 것으로 사료된다.

  • PDF

수치해석을 이용한 화재감지기 철도터널 화재 감지특성 연구 (Sensing Characteristics of Fire Detectors in Railway Tunnel by Using Numerical Analysis)

  • 박원희
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7964-7970
    • /
    • 2015
  • 터널과 같은 밀폐 공간에서는 화재시 발생하는 열과 연기로 인하여 터널내의 승객들에게 심각한 피해를 입힐 수가 있다. 이러한 피해를 최소화하기 위하여 터널의 화재를 조기감지하기 위하여 화재감지기가 터널에 설치된다. 철도터널의 화재감지기 성능시험 방법 정립을 위한 제한된 규모의 화원에서의 터널 상부 및 측벽에 설치된 화재감지기의 감지특성을 수치해석을 이용하여 분석하였다. 화재영향 수치해석을 위하여 NIST에서 개발한 FDS 프로그램을 사용하였으며, 터널벽의 온도를 현실적으로 계산하기 위하여 터널 외부의 구조를 가정하여 고려하였다. 화원크기에 따른 화재감지기별 화재감지 시간을 터널 위치별로 산출하여 비교 분석하였다.

아트리움 공간의 효과적인 방화설비 기준연구 (A study on the standard of effective fire facilities for the Atrium)

  • 최돈묵;김재운;민세홍
    • 한국화재조사학회지
    • /
    • 제6권1호
    • /
    • pp.49-66
    • /
    • 2005
  • 이 연구는 아트리움의 방화안전성 고찰 및 적정한 방화 장치의 기준제시를 초점으로 하고 있다. 주요 내용으로는 아트리움 공간의 일반적 고찰, 아트리움 건물의 실례와 방재상의 문제점을 알아보았고, 현재 우리나라 아트리움 공간에 설치되어 있는 방화설비 등을 조사하여 외국의 여러 기준과 비교함으로써 드러난 문제점 및 취약요인을 바탕으로 아트리움 설계 시 특히 유의하여야 할 사항에 대하여 탐구하였다. 여기서 주장한 아트리움 공간의 효과적인 소화설비기준은 다음과 같다. 1 제연 설비는 비상동력이 부설된 기계제연에 의한 강제배연이 알맞다. 2 아트리움 공간과 연결된 다른 부분에서 공기의 유입이 되지 않도록 연결된 부분(1층 제외)을 화재 시 지동으로 구획되는 가동벽 셔터 방화문을 설치한다. 3. 분리형 적외선 감지기를 아트리움 바닥으로부터 7~8m 높이에 설치하여 조기에 화재를 감지하도록 한다. 4. 천장이 20m이하인 아트리움의 경우 아트리움 천장에 개방형 스프링클러헤드를 설치하고 일제개방밸브를 작동시켜 해당구역에 소화수를 집중 방출하게 하며, 천장이 20m이상인 아트리움의 경우 측벽형 헤드를 저층부의 벽체에 설치하여 수평분출로 소화한다. 5. 피난 계단으로의 이동은 아트리움 공간을 지나지 않고 할 수 있도록 설계되어야한다. 6. 일부부재의 내력저하가 생겨도 전체의 붕괴에는 이르지 않게, 아트리움의 철골의 트러스재는 내화재로 보호한다.

  • PDF

FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구 (Improvement of Fire Detection in Rack-type Warehouses using FDS)

  • 최기옥;박문우;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.55-60
    • /
    • 2019
  • 랙크식 창고에서 화재가 발생되는 경우 건물이 전소되거나 붕괴되는 상태까지 발생된다. 이러한 현상이 발생되는 이유는 랙크식 창고가 층고가 높고, 물품을 수직으로 적재하고 있어 화재 시 천장에 설치되어 있는 감지기에 의한 조기감지가 어렵고, 그로 인하여 초기에 소화하지 못하기 때문이다. 본 연구에서는 수치해석 프로그램인 Fire dynamic simulator (FDS)를 이용하여 랙크식 창고 내에서 화재 시 발생되는 열과 연기의 유동을 분석하였다. 이러한 분석을 통하여 랙크식 창고 내에서 조기 화재감지를 위한 화재감지기의 최적 설치조건을 확인하였다. 그 결과 랙크식 창고에서 조기 화재감지를 위하여 열과 연기의 복합적인 감지가 필요하며, 복합형 감지기를 랙크의 3 level 마다 설치해야 하며, 정온식 감지기는 랙크식 창고에 적합하지 않은 것을 알 수 있었다.