• Title/Summary/Keyword: smartphone inclinometer

Search Result 5, Processing Time 0.016 seconds

Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer (스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구)

  • Yang, Hoesong;Jeong, Chanjoo;Yoo, Youngdae;Bae, Seahyun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.2
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Reliability Study on Hip Joint Range of Motion Measurement by Smartyphone Inclinometer (Smartphone Inclinometer를 이용한 엉덩관절 가동범위 측정 신뢰도 연구)

  • Bae, sea-hyun;Kim, gi-do;Lee, young-shin;Hwang, jin-a;Kim, kyung-yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.399-400
    • /
    • 2015
  • 본 연구는 스마트폰 Inclinometer와 수동 고니오미터를 사용하여 대학생 50명을 대상으로 엉덩관절 운동범위를 검사자 6명이 측정하여 검사자간의 신뢰도를 알아보고자 하였다. 측정결과 높음에서 매우 높은 수준의 신뢰도가 보여, 스마트폰 Inclinometer를 이용한 관절 운동범위 측정값은 수동 고니오미터를 대체 할 수 있을 것으로 생각된다.

  • PDF

Correlationship among Smartphone Screen Time, Cervical Alignment, and Muscle Function in University Students

  • Hyungyu Cha;Seonyoung Hwang;Jinyoung Eo;Hyein Ji;Jiwon Han;Wonjae Choi
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.446-453
    • /
    • 2022
  • Objective: The popularization of smartphones can lead to abnormal cervical alignment in university students. The aim of this study was to investigate the relationship among smartphone screen time, cervical alignment, and muscle function in university students. Design: Cross-sectional study. Methods: Seventy-five university students participated in the study. They completed the evaluation of cervical alignment and muscle function, such as handgrip strength, proprioception, and muscle quality (tone, stiffness, and relaxation time). All participants recorded their general characteristics and individual smartphone screen time before the evaluation. They were evaluated craniovertebral angle (CVA) using smartphone application (angle meter 360) for measuring cervical alignment. The muscle function was assessed using a digital hand-held dynamometer, dual inclinometer, and MyotonPRO device. Results: Of all participants, twenty-five university students had forward head posture (CVA<49°, 33.33%). Independent t-test revealed that there were significant differences on smartphone screen time, muscle stiffness, and muscle relaxation between the participants with and without forward head posture (p<0.05). There were significant correlations between the smartphone screen time and the CVA, muscle tone, and muscle relaxation (r=-0.493, 0.250, and -0.500, respectively). Conclusions: The results indicate that the university students with forward head posture had high smartphone screen time and muscle stiffness compared to the students without forward head posture, and smartphone screen time might be associated with cervical alignment and muscle quality.

Immediate Effects of Roller Massage for Posterior Neck Muscles on the Muscle Strength and Range of Motion for Cranio-Cervical Flexion in Subjects With Forward Head Posture

  • Kang, Seung-tak;Jung, Jang-hun;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.138-145
    • /
    • 2021
  • Background: Forward head posture (FHP) causes various posture imbalances associated with the head and neck. Myofascial release is an effective treatment method used for relaxing muscles and reducing muscle hyperactivity, but no studies have been conducted on suboccipital and neck muscles related to FHP. Objects: The purpose of this study was to investigate the immediate effect of roller massages on the cranio-cervical flexion (CCF) range of motion (ROM) and CCF strength applied to suboccipital and neck muscles in subject with forward head posture. Methods: Twenty-four FHP subjects (male: 13, female: 11) were recruited for this study. All subjects were recruited with a craniovertebral angle (CVA) of 53 degrees or less and a head tilt angle (HTA) of 20.66 degrees or higher. CCF strength was measured using Pressure biofeedback unit (PBU) in the supine posture and CCF ROM was measured using smartphone-based inclinometer. Roller massage (RM) was applied to suboccipital and neck muscles for 2 minutes and CCF ROM and strength were remeasured. Results: These results of this study showed that CCF ROM was a significant difference in CCF ROM before and after RM (p < 0.05). CCF strength also showed a significant difference before and after RM (p < 0.05). Conclusion: RM method might be recommended to increase the immediate ROM and strength of CCF in subjects with forward head posture.