• Title/Summary/Keyword: smart shoe

Search Result 16, Processing Time 0.02 seconds

Implementation of Smart Shoes for Dementia Patients using Embedded Board and Low Power Wide Area Technology (저전력장거리 기술과 임베디드 보드를 이용한 치매 돌봄 스마트 신발 구현)

  • Lee, Sung-Jin;Choi, Jun-Hyeong;Seo, Chang-Sung;Park, Byung-Kwon;Choi, Byeong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.100-106
    • /
    • 2020
  • In this paper smart shoes for dementia care using embedded boards and Low Power Wide Area technology and their application software are implemented. The communication board composed of Cortex-M3 board and LoRa module is embedded into groove made in outsole of smart shoes. Including the mold, the shoe outsole was manufactured by hand. By using application software and embedded board, caregiver can track the position of dementia patient using GPS and LoRa network. The location tracking and data transmission operations of smart shoes have been successfully verified in the outdoor environment. The smart shoes of this paper are applicable to a safety device to prevent the disappearance of demented patients through results of experiments and if bigdata is collected and analyzed by deep-learning, it may be helpful to analyze the predictive path of dementia patients or the pattern of dementia.

An empirical study on IoT-based smart shoe system for health management of childhood obesity (건강관리를 위한 IoT기반 스마트슈즈시스템에 관한 연구)

  • Lee, Min-Ju;Kim, Mun-Ju;Kim, Young-Hyun;Ha, Yeo Ui;Lee, Sang-Jun;Park, Jin-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.765-766
    • /
    • 2017
  • 요즘 전세계적으로 매년 소아비만 빈도가 증가하고 있다. 그리고 소아비만은 더 나아가 성인병의 원인이 될 수 있다. 이런 소아비만과 성인병을 예방하기 위해 스마스슈즈시스템(SMTS1107)을 개발했다. SMTS1107은 걸음 수 측정기능과 몸무게 측정 기능을 갖고 있다.

Gait Analysis According to the changes of the carrying type and weight of bag (가방의 휴대 형태와 무게 변화에 따른 보행 분석)

  • Kim, Chan-Kyu;Lee, Byung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.199-205
    • /
    • 2013
  • The purpose of this study was to analyze the changes in gait according to four style of bag's carryied method and three different bag's weights. Twenty healthy adults participated in four conditions. The first condition, they wearing a bag on one side shoulder and walked. The second condition, they carried a bag sling across on shoulder and walked. The third condition, they carried a bag on a back using both shoulders and walked. The fourth condition, they hold a bag in their right hand and walked. During all four conditions participants wore a SmartStep insole in their right shoe and had a pressure control device strapped to their right ankle. Each participant walked 10 meters carrying a 2.5 kg, 5 kg and 7.5 kg bag under all four conditions. There were significantly differents in stance phase rate; swing phase rate and walking speed according to bag weight of 2.5 kg, 5 kg, 7.5 kg.

The Reliability and Validity of Smart Insole for Balance and Gait Analysis (균형과 보행분석을 위한 스마트 인솔의 신뢰도와 타당도 분석)

  • Lee, Byoung-Kwon;Han, Dong-Wook;Kim, Chang-Young;Kim, Gi-Young;Park, Dae-Sung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose: The Pedisole is a newly developed shoe-mounted wearable assessment system for analyzing balance and gait. This study aimed to determine the reliability and validity of the parameters provided by the system for static balance and gait analysis of healthy adults. Methods: This study included 38 healthy adults (22.4±1.9 years) with no history of injury in the lower limbs. All participants were asked to perform balance and gait tasks for undertaking measurements. For analysis of balance, both the smart Pedisole and Pedoscan systems were concurrently used to analyze the path length of the center of pressure (COP) and the weight ratio of the left and right for 10 s. Gait was measured using the smart Pedisole and GaitRite walkway systems simultaneously. The participants walked at a self-selected preferred gait speed. The cadence, stance time, swing time, and step time were used to analyze gait characteristics. Using the paired t-test, the intra-class coefficient correlation (ICC) was calculated for reliability. The Spearman correlation was used to assess the validity of the measurements. In total, data for balance from 36 participants and the gait profiles of 37 participants were evaluated. Results: There were significant differences between the COP path lengths (p<.050) derived from the two systems, and a significant correlation was found for COP path length (r=.382~.523) for static balance. The ICC for COP path length and weight ratio was found to be greater than .687, indicating moderate agreement in balance parameters. The ICC of gait parameters was found to be greater than .697 except for stance time, and there was significant correlation (r=.678~.922) with the GaitRite system. Conclusion: The newly developed smart insole-type Pedisole system and the related application are useful, reliable, and valid tools for balance and gait analysis compared to the gold standard Pedoscan and the GaitRite systems in healthy individuals.

Using a Stretch Sensor About of Squat Ankle Range of Motion Check Socks -Focusing on Men in Their Late 20s- (스트레치 센서를 이용한 스쿼트 시 발목 가동범위 체크 센서 양말에 관하여 -20대 후반 남성을 중심으로-)

  • Song, Kwanwoo;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.26 no.2
    • /
    • pp.129-142
    • /
    • 2022
  • The purpose of this study is to develop socks to check the range of ankle movement during squats for men in their late 20s. Sensors of 6, 8, and 12 mm were selected, and each sample was impregnated 1 to 3 times. It was prepared using a CNT dispersion, and the GF value was measured using UTM. Among them, the sample with 2 impregnation showed the best GF value. As a result of applying each sample to the socks, the 12 mm sensor was wider than the area of the Achilles tendon, resulting in noise, and the 8 mm sensor was higher than the tensile strength of the socks, resulting in a decrease in the graph. Therefore, testing was performed using a 6 mm sensor. In order to determine the effectiveness of the sensor, the normal operating range was checked through squats, and significant changes were confirmed when the operating range was checked again through squats by performing operations that can increase the operating range through Gastrocnemius, Soleus stretching, and low lunge. Using the results of this study, it is expected that the average value of the ankle movement range of the user is checked prevent injury, to be provided as basic data for the production of shoe products and the promotion of physical health.

An indoor localization system for estimating human trajectories using a foot-mounted IMU sensor and step classification based on LSTM

  • Ts.Tengis;B.Dorj;T.Amartuvshin;Ch.Batchuluun;G.Bat-Erdene;Kh.Temuulen
    • International journal of advanced smart convergence
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 2024
  • This study presents the results of designing a system that determines the location of a person in an indoor environment based on a single IMU sensor attached to the tip of a person's shoe in an area where GPS signals are inaccessible. By adjusting for human footfall, it is possible to accurately determine human location and trajectory by correcting errors originating from the Inertial Measurement Unit (IMU) combined with advanced machine learning algorithms. Although there are various techniques to identify stepping, our study successfully recognized stepping with 98.7% accuracy using an artificial intelligence model known as Long Short-Term Memory (LSTM). Drawing upon the enhancements in our methodology, this article demonstrates a novel technique for generating a 200-meter trajectory, achieving a level of precision marked by a 2.1% error margin. Indoor pedestrian navigation systems, relying on inertial measurement units attached to the feet, have shown encouraging outcomes.