• 제목/요약/키워드: small-scale H

검색결과 422건 처리시간 0.025초

Ti-6Al-4V, Ti-4Fe, Ti-(1,2)Si합금의 고온산화 (High Temperature Oxidation of Ti-6Al-4V, Ti-4Fe, Ti-(1,2)Si Alloys)

  • 박기범;이동복
    • 한국표면공학회지
    • /
    • 제34권2호
    • /
    • pp.135-141
    • /
    • 2001
  • Arc-melted Ti-6Al-4V, Ti-4Fe and Ti-(1,2) Si alloys were oxidized at 700, 800, 900 and $1000^{\circ}C$ in air. The oxidation resistance of Ti-4Fe was comparable to that of Ti-6Al-4V, while the oxidation resistance of Ti-(1,2) Si was superior to that of Ti-6Al-4V. Ti-2Si displayed the best oxidation resistance among the four alloys, but failed after oxidation at $1000^{\circ}C$ for 17h. The oxide scale formed on Ti-6Al-4V, Ti-4Fe and Ti-(1,2)Si consisted of ($TiO_2$ and a small amount of $Al_2$$O_3$), ($TiO_2$ and a small amount of dissolved iron), and ($TiO_2$ plus a small concentration of amorphous $SiO_2$), respectively. The oxide grains of the surface scale of the four alloys were generally fine and round.

  • PDF

Study on iodine Labelling (II) Efficient of Labelling Rose Bengal, Hippuran, and Human Serum Albumin in Small Scale

  • Kim, Jaerok
    • Nuclear Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.186-193
    • /
    • 1972
  • Rose $Bengal-^{131}$ /I, $Hippuran-^{131}$ /I, $H.S.A-^{131}$ /I 등을 효과적으로 합성하기 위해 표지 반응액의 pH, 염의함량, 반응액중의 완충용액의 부피 및 합성장치등에 따르는 표지 반응수율을 검토하였다. Rose $Bengal-^131{ }$I 및 $Hippuran-^{131}$ /I 의 반응수율은 PH 5.6에서, $H.S.A-^{131}$ /I 반응수율은 pH 8.5에서 각각 가장 좋았다. 반응액중에 함유된 염은 $Hippuran-^{131}$ /I의 생성반응을 크게 저해 시켰으며 H.S.A.의 표지수율은 어느 범위안에서 오히려 약간 향상시켰다. Rose $Bengal-^{131}$ /I 나 $Hippuran-^{131}$ /I 를 소규모 합성할 경우는 밀폐된 용기가 효과적이었다. 이상의 결과에 따라 더 높은 표지수율과 좋은 재현성을 얻을 수 있는 반응조건을 확립하였으며 이에 따라 환원제가 함유된 국산 $Na^{131}$ /I를 사용하더라도 Rose $Bengal-^{131}$ /I과 $Hippurn=^{131}$ /I의 표지수율을 높일 수 있었다.

  • PDF

소규모 매립가스 자원화를 위한 마이크로터빈 열병합발전 및 유리온실 $CO_2$ 농도 증가 시스템의 타당성 연구 (Feasibility Study of Microturbine CHP and Greenhouse $CO_2$ Enrichment System as Small Scale LFG Energy Project)

  • 박정극;허광범;임상규;이인화
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.15-24
    • /
    • 2009
  • As new small scale LFG (landfill gas) energy project model which can improve economic feasibility limited due to the economy of scale, LFG-Microturbine combined heat and power system with $CO_2$ fertilization into greenhouses was proposed and investigated including basic design process prior to the system installation at Gwang-ju metro sanitary landfill. The system features $CH_4$ enrichment for stable microturbine operation, reduction of compressor power consumption and low CO emission, and $CO_2$ supplement into greenhouse for enhancement plant growth. From many other researches, high $CO_2$ concentration was found to enhance $CO_2$ assimilation (also known as photosynthesis reaction) which converts $CO_2$ and $H_2O$ to sugar using light energy. For small scale landfills which produce LFG under $3\;m^3$/min, among currently available prime movers, microturbine is the most suitable power generation system and its low electric efficiency can be improved with heat recovery. Besides, since its exhaust gas contains very low level of harmful contaminants to plant growth such as NOx, CO and SOx, microturbine exhaust gas is a suitable and economically advantageous $CO_2$ source for $CO_2$ fertilization in greenhouse. The LFG-Microturbine combined heat and power generation system with $CO_2$ fertilization into greenhouse gas to enhance plant growth is technologically and economically feasible and improves economical feasibility compared to other small scale LFG energy project model.

  • PDF

뜨임한 구조용강 SCM435의 경도 및 충격 흡수에너지에 대한 신뢰성 평가 (Reliability Evaluation of Hardness and Impact Absorption Energy of Tempered Structure Steel SCM435)

  • 윤서현;구세훈;남기우
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.681-688
    • /
    • 2019
  • SM45C steel, which is widely used for mechanical structure, was carburized at 870℃ for 4 hours and tempered at 300℃ and 400℃ for 1, 3 and 6 hours. The tempered materials were evaluated for tensile test, hardness test and impact test. In particular, the hardness and the absorption energy were evaluate the reliability by the Weibull statistical analysis. 300℃-1h specimen is considered to be the best heat treatment condition in the tensile stress and the observation of fracture surface. 300℃-1h specimen showed larger shape and scale parameter than the other specimens, and Rockwell hardness variance was small and showed the best characteristics. 400℃-3h specimen showed larger shape and scale parameter than the other specimens, the dispersion of impact absorption energy is small, and showed excellent characteristics.

소형가스루프 시험조건에서 중형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Medium-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.33-38
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to a chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute has established a small-scale gas loop for the performance test on VHTR components and recently has manufactured a medium-scale PHE prototype made of Hastelloy-X. A performance test on the PHE prototype is scheduled in the gas loop. In this study, high-temperature structural analysis modeling, and macroscopic thermal and structural analysis of the medium-scale PHE prototype by imposing the established displacement boundary constraints in the previous research were carried out under the gas loop test condition. The results obtained in this study will be compared with performance test results.

Liquid entrainment through a large-scale inclined branch pipe on a horizontal main pipe

  • Gu, Ningxin;Shen, Geyu;Lu, Zhiyuan;Yang, Yuenan;Meng, Zhaoming;Ding, Ming
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1164-1171
    • /
    • 2020
  • T-junction structures play an important role in nuclear power plant systems. Research on liquid entrainment is mostly based on small-scale branch pipes (d/D ≤ 0.2) and attention paid to large-scale branch pipes (0.33 < d/D < 1) is insufficient. Accordingly, this study implements a series of experiments on the liquid entrainment of T-junction with different angles (32.2°,47.9°,62.3°,90°) through a large-scale branch (d/D = 0.675). The onset liquid entrainment is related to the gas phase Froude number Frg, the dimensionless gas chamber height hb/d and the branch pipe angle 𝜃. As Frg increases, hb/d also rises. With a constant hb/d, the onset liquid entrainment changes from droplets entrainment by the gas phase to that by the rising liquid film. The steady-state liquid entrainment is related to w3g, h/d and 𝜃. With constant w3g and h/d, the branch quality grows as the branch angle increases. With a certain h/d, the branch quality increases, as the w3g number increases.

Similarity of energy balance in mechanically ventilated compartment fires: An insight into the conditions for reduced-scale fire experiments

  • Suto, Hitoshi;Matsuyama, Ken;Hattori, Yasuo
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2898-2914
    • /
    • 2022
  • When evaluating energy balance and temperature in reduced-scale fire experiments, which are conducted as an alternative to full-scale fire experiments, it is important to consider the similarity in the scale among these experiments. In this paper, a method considering the similarity of energy balance is proposed for setting the conditions for reduced-scale experiments of mechanically ventilated compartment fires. A small-scale fire experiment consisting of various cases with different compartment geometries (aspect ratios between 0.2 and 4.7) and heights of vents and fire sources was conducted under mechanical ventilation, and the energy balance in the quasi-steady state was evaluated. The results indicate the following: (1) although the compartment geometry varies the energy balance in a mechanically ventilated compartment, the variation in the energy balance can be evaluated irrespective of the compartment size and geometry by considering scaling factor F (∝heffAwRT, where heff is the effective heat transfer coefficient, Aw is the total wall area, and RT is the ratio of the spatial mean gas temperature to the exhaust temperature); (2) the value of RT, which is a part of F, reflects the effects of the compartment geometry and corresponds to the distributions of the gas temperature and wall heat loss.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

PC를 이용한 소규모 기가비트 VLBI 관측시스템 (SMALL-SCALE GIGABIT VLBI OBSERVATION SYSTEM USING PC)

  • 오세진;노덕규;김광동;정현수;제도흥;위석오;한석태;김현구
    • 천문학논총
    • /
    • 제20권1호
    • /
    • pp.125-134
    • /
    • 2005
  • In this paper, we propose a small-scale Gigabit VLBI observing system for the Korean VLBI Network (KVN) under construction. The system consists of high-speed sampler, IP-VLBI board, PC-VSI board, and software correlator. Radio signal received by receiver is sampled by high-speed sample. at 1 Gsps (Gigabit sample per second) rate with 2 bits quantization. The digitized signal is recorded in PC and the software correlator does the cross correlation. IP-VLBI board will be used for the geodesy VLBI observation, while PC-VSI board is for the astronomical VLBI observation. The PC-VSI board adopts the VSI-H (VLBI Standard Interface Hardware). The proposed system is based on commercial PCs and therefore can be built inexpensively.

Testing a Small Scale Aseptic System for Milk in Plastic Bottles

  • Petrus, Rodrigo Rodrigues;Faria, Jose de Assis Fonseca
    • Food Science and Biotechnology
    • /
    • 제16권1호
    • /
    • pp.18-22
    • /
    • 2007
  • The objective of this study was to develop and assess the performance of an aseptic system for liquid milk contained in plastic bottles, from a small-scale production standpoint. Commercial sterility tests conducted on the bottled milk were utilized in our assessments of the system, via the identification and monitoring of the principal points of the process. Four 150 L batches of milk with pH values of approximately 6.7 were heat-processed at between 137 and $143^{\circ}C$ for 10 see in a plate heat exchanger, and then aseptically transferred to 500 mL high-density polyethylene (HOPE) bottles, in an ISO class 7 clean room. The aseptic condition of the bottles was achieved via 10 see of rinsing with a mixture containing 0.5% peracetic acid and 0.8% hydrogen peroxide at $30^{\circ}C$, followed by another rinse with sterile water. Of the 4 batches processed, 2 were determined to exhibit commercial sterility, on the basis of the physical-chemical and microbiological criteria adopted. It was concluded that some adjustment of the processing line was required in order to achieve full commercial sterility for all processes. The aseptic system developed and assessed in this study was demonstrated to have great potential for the processing and transferring of milk into plastic bottles, from a small-scale production standpoint.