• Title/Summary/Keyword: small wind power

검색결과 330건 처리시간 0.03초

50kW 풍력발전기의 출력 성능에 관한 연구 (A study of Power Performance for 50kW Wind Turbine)

  • 김형길;공정식;권기진;오진훈;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1068-1069
    • /
    • 2015
  • Wind turbines have an enormous potential for decentralized electricity generation. In recent years, there has been an increasing worldwide interest in small/medium wind systems. This paper presents the results of power performance testing conducted on a 50 kW turbine located in Yeonggwang test-bed. The turbine system is a pitch, active yaw, variable speed, upwind, three blade with a direct drive PMSG. This thesis covers the operation of variable speed wind turbines with pitch-yaw control. The system considered is controlled to generate maximum energy while minimizing loads. The data include power, wind speed, and direction from meteorological towers, and nacelle anemometer readings and output from turbine. The analysis concentrates on the effect of the load on the power-wind speed curve of the turbine.

  • PDF

풍력에너지 개발을 위한 국제교류 및 공동연구 현황 (International Cooperation on Information Exchange and Research for Wind Energy Development)

  • 김철완
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.249-251
    • /
    • 2011
  • International energy agency(IEA) consisted of OECD countries deals with international energy problems. IEA/Wind ExCo is an execution committee under IEA for the implementing agreement for co-operation in the research, development and deployment of wind energy systems. Currently 22 countries participate the committee and 11 research tasks are in progress. 11 tasks are base technology information exchange, wind energy in cold climates, offshore wind energy technology deployment, integration of wind and hydropower systems, power systems with large amounts of wind power, cost of wind energy, labelling small wind turbines, social acceptance of wind energy projects, MexNext aerodynamics and comparison of dynamic computer codes and models, offshore wind energy and wakebench. At the presentation, activities of major wind energy countries and IEA/Wind ExCo and research tasks are introduced.

  • PDF

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안 (A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator)

  • 장미혜;신백식;송원진;김영민;김동용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

도시형 풍력발전 시스템을 위한 퍼지로직 기반 MPPT 알고리즘 개발 (Design of Fuzzy Logic based MPPT(Maximum Power Point Tracking) Algorithm for Urban Wind Turbine System)

  • 육의수;김성호;이장호;장미혜
    • 한국지능시스템학회논문지
    • /
    • 제20권1호
    • /
    • pp.21-29
    • /
    • 2010
  • 일반적으로 풍력발전은 광범위한 영역에 지속적인 바람을 요구하는 대형 시스템 위주로 개발이 되어왔다. 그러나 소형 풍력발전 시스템은 유저에게 보다 친숙하고, 대형에 비해 보다 광범위한 적용이 가능하다는 점 때문에 최근 이에 대한 관심이 증가되고 있는 실정이다. 이에 본 연구에서는 배터리 충전에 효과적으로 도입될 수 있는 도시형 풍력발전을 위한 프로토타입 시스템에 대해 기술하며, 프로토타입 시스템에 효과적으로 도입될 수 있는 퍼지로직 기반의 최대 전력점 추종 알고리즘을 제안하고자 한다. 또한 제안된 기법의 유용성 확인을 위해 Matlab을 통한 시뮬레이션 및 이를 통해 얻어진 알고리즘을 실제 DSP에 적용하여 보고자 한다.

풍력발전의 전력저장을 위한 베터리 충전회로에 관한 수학적인 모델링 (A Mathematical Modeling on Battery Charging Circuit for the Power Storage of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.301-304
    • /
    • 2001
  • Wind power generation system is one of the most useful energy resource using natural environment. One of the biggest problem we encountered is toot the wind speed is fluctuating sharply according to the weather conditions rather than it is stable. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We analyse a battery charging characteristics for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we make a small size model usable in actual wind power generation system of 30kw and make an experiment and confirm its validity.

  • PDF

울릉도 계통에 대한 플라이휠 최적 용량 산정에 관한 연구 (A Study on Optimal Flywheel Capacity Estimation for Ulleung-do Power System)

  • 최승원;이한상;이정필;한상철;성태현;한영희;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.606-607
    • /
    • 2007
  • This paper is about optimal flywheel capacity estimation for Ullueng-do power system. The power system of Ullueng-do has some differences with other island power system in Korea. It includes wind generator, hydro-generators as well as diesel generators. There are some problems on 600kW wind generator. Because of frequent drop of wind generator, the Ulleung-do power system have been threatened on frequency. The power frequency is 60Hz, and it should be between 59.9 and 60.1Hz. However, since the electrical inertia is small and the weight of wind generation is relatively high, generator drop of wind generation might make the power frequency out of boundary. In this paper, the flywheel energy storage system is assumed to be installed on Ulleung-do power system. Then, the maximum wind generation capacity and the optimal superconducting flywheel energy storage system capacity is estimated by the transient stability simulations.

  • PDF

해상풍력산업 발전을 위한 중소·중견 기업 지원 방안 연구 (A Study on Supporting Small and Medium Enterprises for the Development of Offshore Wind Industry)

  • 최영문;최정호
    • 한국융합학회논문지
    • /
    • 제12권5호
    • /
    • pp.167-172
    • /
    • 2021
  • 세계 해상풍력 시장의 밝은 성장 전망과 우리 정부의 의욕적인 계획에 힘입어 국내 해상풍력 시장의 성장 가능성에 대한 기대감이 한층 높아지고 있는 상황에서 국내 해상풍력의 성공적인 발전을 위한 방안과 실무 전문가들의 실질적인 애로사항에 대해 조사 분석한 내용을 토대로 개선방안을 제시한다. 또한 관련 중소기업을 육성하기 위해 실무적 지원 방안을 제시한다. 연구결과와 개선방안은 설문조사결과를 토대로 하였으며, 그 내용은 다음과 같다. 첫째, 대기업 위주로 기술개발이 이루어지면서 중소제조업에 대한 발전여력이 매우 저조한 실정으로, 정부기관이 주도하는 클러스터 핵심센터를 설립·운영하여 국가 연구기관들과 대기업의 주도로 기술지원을 하고, 대학교와 국가 연구기관들이 함께 전문인력 양성 및 연구개발을 통한 중소·중견 기업들의 자립력을 강화시킬 필요가 있다. 둘째, 기업의 실무적 지원방안에 대한 설문조사 결과 기술개발과 생산된 부품에 대한 사업화를 위한 다양한 지원이 이루어져야 할 필요성이 있는 것으로 나타났다.

Electromagnetic Structural Design Analysis and Performance Improvement of AFPM Generator for Small Wind Turbine

  • Jung, Tae-Uk;Cho, Jun-Seok
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.374-378
    • /
    • 2011
  • Axial Field Permanent Magnet (AFPM) generators are widely applied for the small wind turbine because of the higher power density per unit weight than that of the conventional radial field generator. It is caused by the disc shaped rotor and the stator structures. The generally used AFPM generator, AFER-NS generator, is composed of the two side's external rotors and non-slotted stator without stator core. However, the output voltage and the output power are limited by the large reluctance by the long air-gap flux paths. In this paper, the design study of AFIR-S generator having double side's slotted stator core is accomplished to improve the output generation characteristics. The electromagnetic design analysis and the design improvement of the suggested AFIR-S generator are studied. Firstly, the electromagnetic design analysis was done to increase the power density. Secondly, the design optimizations of the rotor pole-arc ratio of permanent magnet are accomplished to increase the output power and to reduce the cogging torque. Finally, the output performances of AFER-NS and AFIR-S generator are compared with each other. For this study, 3D FEA is applied for the design analysis because of three dimensional electromagnetic structures.

풍력용 소용량 영구자석형 발전기의 설계 (Design of Small-Scaled Permanent Magnet Generators for Wind Power Applications)

  • 장석명;최장영;조한욱;유대준;경남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.194-196
    • /
    • 2006
  • This paper deals with design of a small-scaled permanent magnet generator (PMG) for wind power applications. First, this paper determines rated power and rated speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot. Finally, finite element (FE) method is employed for validity of the designed PMG and, the back-emf measurements are also given to confirm the design.

  • PDF