• 제목/요약/키워드: small impact test device

검색결과 10건 처리시간 0.027초

Design of small impact test device for concrete panels subject to high speed collision

  • Kim, Sanghee;Jeong, Seung Yong;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • 제7권1호
    • /
    • pp.23-30
    • /
    • 2019
  • Five key items were used to create an economical and physically small impact test device for concrete panels subject to high speed collision: an air-compressive system, carbon steel pipe, solenoid valve, carrier and carrier-blocking, and velocity measurement device. The impact test device developed can launch a 20 mm steel spherical projectile at over 200 m/s with measured impact and/or residual velocity. Purpose for development was to conduct preliminary materials tests, prior to large-scale collision experiments. In this paper, the design process of the small impact test device was discussed in detail.

비젼 피드백 제어를 이용한 광통신 Laser Diode Test Device 개발 (Development of Laser Diode Test Device using Feedback Control with Machine Vision)

  • 유철우;송문상;김재희;박상민;유범상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1663-1667
    • /
    • 2003
  • This thesis is on tile development of LD(Laser Diode) chip tester and the control system based on graphical programming language(LabVIEW) to control the equipment. The LD chip tester is used to test the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the receiver(optic fiber) are very small. Therefore, in order to test each chip precisely, this tester needs high accuracy. However each motion part of the tester could not accomplish hish accuracy due to the limit of the mechanical performance. Hence. an image processing with machine vision was carried out in order to compensate for the error. and also a load test was carried out so as to reduce tile impact of load on chip while the probing motion device is working. The obtained results were within ${\pm}$5$\mu\textrm{m}$ error.

  • PDF

마그네틱 파우더 브레이크를 이용한 소형 진자형 충격시험기 개발 (Development of a Miniature Pendular Type Impact Testing Machine Using a Magnetic Powder Brake)

  • 유인동;이만석;김호경
    • Tribology and Lubricants
    • /
    • 제27권3호
    • /
    • pp.140-146
    • /
    • 2011
  • A miniature pendular type impact testing machine was designed and developed, adopting a magnetic powder brake in order to investigate tensile and shear behavior of a small solder ball at high speed. In this testing system, the potential energy of the pendulum is transferred into the impact energy during its drop. Then, the impact energy is transmitted through the striker which is connected to the push rods to push the specimen for tensile loading. The tensile behavior of lead-free solder ball in diameter of 760 ${\mu}m$ was successfully investigated in a speed range of 0.15 m/s~1.25 m/s using this designed device. The maximum tensile strength of the solder joint decreases with the loading speed in the testing condition. The maximum tensile strength of the joint was 56 MPa in the low speed region.

타격조건에 따른 수박의 음파특성 (Acoustic Characteristics of Watermelon According to Impact Conditions)

  • 최동수;최규홍;이영희;이강진;김만수
    • Journal of Biosystems Engineering
    • /
    • 제27권1호
    • /
    • pp.67-76
    • /
    • 2002
  • This study was conducted to investigate the effects of impact conditions on the acoustic characteristics of a watermelon. The study was crucial to develop a device for nondestructive internal quality evaluation of a watermelon by an acoustic impulse response method. An impact device was constructed with a pendulum to hit the watermelon, a microphone to detect the acoustic impulse responses, and a digital oscilloscope and computer to store and analyze the data. The selected samples were Guemcheon cultivar watermelons(Citrulus Vulgaris Schrad) harvested on Oct. 20,1998. Sixty watermelons were tested on flour different types of sample holders, with four kinds of ball made of different materials, at four bevels of the angular position of the pendulum and distance from the watermelon to the microphone. Since the magnitudes of frequencies obtained by hitting with the steel and rubber ball were relatively small at the bandwidths of above 500 Hz, it was shown that the steel and rubber ball were not suitable far a hitting ball in the pendulum to get informations on internal quality of the watermelon. In case of using broth of the wood and acryl ball, almost the same and good acoustic responses were shown on the wide range of frequency bandwidth. Therefore, it seemed that the acryl ball was more suitable to the test than the wood ball in considering its mechanical properties. The acoustic characteristics of the watermelon were not shown a significant difference between the types of sample holder. The amplitudes of the acoustic signals and the magnitudes of frequencies from the whole samples increased with increase of the angular position of pendulum and with decrease of the distance from the watermelon to the microphone. However, the resonance resonance of the sample were almost the same regardless of the angular positions and the distances.

수분 밀폐형 컴퓨터시스템(MPC) 개발 - MPC의 성능평가 - (Development of the Moisture Protected Computer - Efficiency Test of the MPC -)

  • 김진현;김태욱;성광기
    • 한국산업융합학회 논문집
    • /
    • 제10권2호
    • /
    • pp.115-122
    • /
    • 2007
  • The MPC(Moisture Protected Computer) system is completely unique. It was recently invented in Korea and it is a technological break-through in the field of computer systems. It will be instrumental in the development of a complete moisture air-tight capability and will work well in field environments. The MPC includes the following: 1) An enclosed design. 2) Moisture proof computer enclosure joints. 3) System dust protection & an impact buffing system. 4) A normal temperature maintenance system when the temperature inside the computer is low. 5) The ability to generate heat and a radiate system inside the computer 6) An automatic power input sensing controller device. 7) A safety device in case of mis-operation. 8) A proper admission procedure for various tests. Because of the above, and as a result of temperature property experiments, there aren't any operational problems. The result of this treatise could provide very important data for verification of cases involving: using strong materials to protect against explosions, searching for ways to make the size and weight small, and for making repairs easier. As a result, it could achieve price and function competitiveness in advanced countries such as the USA and in Europe.

  • PDF

기술발전단계에 따른 중소기업의 기술협력 형태변화에 관한 탐색적 연구

  • 정진우;배종태
    • 기술경영경제학회:학술대회논문집
    • /
    • 기술경영경제학회 1997년도 제11회 하계학술발표회 논문집
    • /
    • pp.195-221
    • /
    • 1997
  • This study examines the changing patterns of technological cooperation activities along technological development stages. Based on the longitudinal sample of 58 small and medium-sized companies in telecommunication equipment and device sectors, proposed hypotheses are tested using paired comparison t-test, ANOVA and multiple regression analysis. Major findings of this study are as follows. Along technological development stages, (1) patterns of technological cooperation activities differ in terms of the extent and diversity of use, partners, method, and motivation and (2) the impact of specific forms of technological cooperation activities on the firm's technological innovation varies. In addition, some managerial and policy implications are presented and future research directions are suggested.

  • PDF

승객보호용 랩을 적용한 저위험성 조수석 에어백의 미국 연방 자동차안전 기준법규에 의거한 시험과 평가 (Test and Evaluation based on Standard Regulation of USA Federal Automotive Safety of Assistant Driver's Seat Airbag at Low Risk Deployment Passenger Airbag using Passenger Protection Wrap)

  • 김동은;김진형;강명창
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.61-67
    • /
    • 2016
  • The airbag is a widely accepted device for occupant protection in the automotive industry. As the injuries induced by airbag deployment have become a critical issue, revisions to Federal Motor Vehicle Safety Standard (FMVSS) 208 were required to create advanced airbags that can protect occupants of varying statures. In this paper, we developed a new low-risk deployment passenger airbag by adding the Passenger Protection Wrap (PPW). The PPW reduces the cushion impact force to the occupant in order to ensure pressure dispersion. A series of tests were conducted by using FMVSS 208 test procedures to demonstrate the proposed system. It was found that the system not only satisfied the injury criteria of FMVSS 208 but was also effective for protecting passengers of all sizes (male, small female, 3-year-old, 6-year-old).

사용적합성 평가를 적용한 국산 범용인공호흡기의 위험요인 분석 (Analysis of Hazard Factors for Domestic General Purpose Ventilator using Usability Assessment)

  • 권경민;김승희;김유림;장원석
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권1호
    • /
    • pp.10-19
    • /
    • 2024
  • The purpose of this study is to conduct a summative evaluation of the usability of a general-purpose ventilator to determine whether it can be used for its intended purpose in the intended environment by the intended user and to find possible errors in use. The importance of ventilators has increased due to the accelerated aging of the population and the impact of the pandemic. In addition, patients who require ventilators are often in critical condition, so even a small error in use can be fatal. Therefore, it is important to ensure that the ventilator has sufficient stability and can be used satisfactorily without inconvenience to the user. In this study, we conducted a usability test with 17 respiratory nurses with more than 3 years of experience using the ventilator. We analyzed the task success rate, satisfaction, and opinions of the intended users while going through a total of 17 scenarios. Satisfaction was captured through an ASQ questionnaire and subjective opinions were captured through a detailed opinion questionnaire. The results showed a high level of satisfaction with an average score of 6.3 for the use scenarios. Evaluators expressed satisfaction with the overall visibility and versatility of the features, but noted that improvements were needed for calibration tasks with low task success rates. As the calibration method is different from other equipment, it was suggested that specific explanations of the calibration method and the picture that appears when calibrating are needed, and that if relevant training is provided, the equipment can be used without problems. If the usability evaluation is not limited to securing efficiency and satisfaction from the intended users, but also continuously receives feedback from users to prepare for use in emergency environments such as pandemic situations, it will be very helpful to seize opportunities such as emergency authorization in future situations, and ultimately contribute to patient safety by reducing use errors.

Intraosseous anesthesia in symptomatic irreversible pulpitis: Impact of bone thickness on perception and duration of pain

  • Nilius, Manfred;Mueller, Charlotte;Nilius, Minou Helene;Haim, Dominik;Leonhardt, Henry;Lauer, Guenter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.367-375
    • /
    • 2020
  • Background: Intraosseous anesthesia (IO) allows the anesthetic solution to be injected directly into the cancellous bone. The anesthetic solution immediately reaches the periapical region, and thus the axonal area of the nerve, where it can temporarily disable the sodium pump. The effect is felt almost without any time delay, and only a small amount of anesthetic solution is required. Methods: This study aims to investigate the efficacy of IO using the AnestoⓇ device after infiltration anesthesia (IA) and/or inferior alveolar nerve block anesthesia (IANB) failed to work in symptomatic irreversible pulpitis (hot tooth). The 33 patients included in the study were treated additionally with 1.7 ml articaine hydrochloride with 1:100,000 epinephrine hydrochloride (UltracainⓇ D-S, Sanofi-Aventis, Frankfurt, Germany) IO. Results: The electrical pulp test showed that 95.76% of the volunteers reacted positively to the combination of IANB or IA with the IO. In women, the additive IO was effective at 97.22%. In men, the IO led to pain elimination in 94.00% of cases. The duration of the IO was less than a quarter of an hour (13.03 min). The IO worked longer in women than in men (13.61 min vs. 12.33 min). Overall, more than every third tooth that needed trepanation was located in the posterior area of the mandible (36.4%). Treatment of hot teeth in this area was associated with an increased pulse rate and increased residual pain. There was a moderate correlation (Spearman-Rho [IRI] = 0.280) between the Visual Analog Scale (VAS) score and bone density, and a significant correlation (IRI = 0.612) between subjective residual pain and bone width. The IO resulted in a moderate, transient increase in the pulse rate by approximately 20 bpm. This is similar to the temporary increase in heart rate after conventional anesthesia techniques in non-preloaded patients and can be considered clinically irrelevant. Conclusion: IO with the AnestoⓇ device as an extension and deepening of local pain elimination is recommended for the treatment of hot teeth.

콘크리트 수로 탈출로 경사각에 따른 한국산개구리 행동 분석 (Analysis of Rana coreana Behavior According to the Slope Angle Degree of Escape Ramp)

  • 이태호;김중권;서지혜;장문정;최태영;장민호
    • 환경영향평가
    • /
    • 제31권1호
    • /
    • pp.75-81
    • /
    • 2022
  • 본 연구의 목적은 콘크리트 U형 벤치 플륨관 수로에 설치되는 수로 탈출 경사로의 경사각에 따른 개구리 행동 특성을 분석하여 탈출 경사로 기준 각도를 제언하는 것이다. 실험 장치는 현장에서 적용되는 콘크리트 수로 탈출장치와 형태 및 재질을 유사하게 제작하였다. 경사로 실험을 위해 논 습지에 서식하는 한국산개구리를 선정하였다. 경사로에서 보여지는 개구리의 주요 행동은 '뛰기', '걷기', '미끄러짐'이었으며, 경사각에 따른 행동 결과를 기록한 후 통계 분석하였다. 경사각은 20°-60° 범위에서 10° 간격으로 5개의 경사각을 설정하여 비교·분석하였다. 연관성 검증은 카이제곱 검증 방법을 사용하였다. 분석결과 30°와 40°는 통계적으로 유의한 차이가 없었다. 이는 '생태통로 설치 및 관리지침'의 30° 이하의 설치 기준에 있어, 현장에서 이를 40°까지 일부 허용해 줄 수 있는 근거로 활용될 수 있는 결과이다. 하지만 수로 탈출 경사로가 한국산개구리뿐 아니라 다양한 소형 야생동물을 대상으로 하고 있다는 점에서 추가 연구가 필요할 것이다.