• Title/Summary/Keyword: small animal imaging

Search Result 132, Processing Time 0.024 seconds

Congenital mitral valve stenosis in a Chinchilla cat

  • Lu, Ta-Li;Hung, Yong-Wei;Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.197-200
    • /
    • 2016
  • A one-year-old, 3.25 kg intact male Chinchilla cat presented with acute right hind limb paralysis. Diagnostic imaging studies found cardiomegaly with interstitial lung pattern, abnormal mitral valve leaflets without maximum opening at the end of the ventricular diastole and during atrial systole and severe mitral inflow obstruction. Based on these findings and its young age, the case was diagnosed as congenital mitral valve stenosis. Treatment was directed to stabilize clinical conditions related to heart failure, to prevent further formation of thrombus and to relieve pain associated with thromboembolism. After one month of therapy, hind limb motor function was fully recovered.

Medical Applications of Near Infrared Spectroscopy and Diffuse Optical Imaging (Review) (근적외선 분광법 및 확산 광 영상법의 최근 연구 동향)

  • Lee, Seung-Duk;Kwon, Ki-Won;Koh, Dal-Kwon;Kim, Beop-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.89-98
    • /
    • 2008
  • NIRS (Near-infrared Spectroscopy) and DOI (Diffuse Optical Imaging) are relatively new, non-invasive, and non-ionizing methods that measure or image optical properties (Scattering and Absorption Coefficient) and physiological properties (Water Fraction, concentration of Oxy-, Deoxy-Hemoglobin, Cytochrome Oxidase, etc) of biological tissues. In this paper, three different types of NIRS systems, mathematical modeling, and reconstruction algorithms are described. Also, recent applications such as functional brain imaging, optical mammography, NIRS based BMI (Brain-Machine Interface), and small animal study are reviewed.

Multimodality Image Registration and Fusion using Feature Extraction (특징 추출을 이용한 다중 영상 정합 및 융합 연구)

  • Woo, Sang-Keun;Kim, Jee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.123-130
    • /
    • 2007
  • The aim of this study was to propose a fusion and registration method with heterogeneous small animal acquisition system in small animal in-vivo study. After an intravenous injection of $^{18}F$-FDG through tail vain and 60 min delay for uptake, mouse was placed on an acryl plate with fiducial markers that were made for fusion between small animal PET (microPET R4, Concorde Microsystems, Knoxville TN) and Discovery LS CT images. The acquired emission list-mode data was sorted to temporally framed sinograms and reconstructed using FORE rebining and 2D-OSEM algorithms without correction of attenuation and scatter. After PET imaging, CT images were acquired by mean of a clinical PET/CT with high-resolution mode. The microPET and CT images were fusion and co-registered using the fiducial markers and segmented lung region in both data sets to perform a point-based rigid co-registration. This method improves the quantitative accuracy and interpretation of the tracer.

  • PDF

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

Long-term Chemotherapy with Lomustine Plus Hydroxyurea for Choroid Plexus Papilloma in a Schnauzer Dog

  • Jung, Dong-In;Song, Joong-Hyun;Jung, Hae-Won;An, Su-Jin;Hwang, Tae-Sung;Lee, Hee-Chun;Sur, Jung-Hyang;Cho, Kyu-Woan
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.94-97
    • /
    • 2017
  • A 10-year-old male Schnauzer dog presented with a 1-week history of ataxia, right-sided hemiparesis, and right-sided head tilt. On the basis of magnetic resonance imaging (MRI) with neurological examination and cerebrospinal fluid analysis results, a primary brain tumor was suspected. Therapy with imatinib mesylate plus hydroxyurea for 7 weeks was not effective and clinical signs worsened. Chemotherapy was then changed to lomustine plus hydroxyurea. Although the existing clinical signs continued, they did not deteriorate. No change in mass size was observed in subsequent MRI. The subject suddenly died from dyspnea 388 days after initial presentation. In this case, choroid plexus papilloma was definitively diagnosed based on histopathological findings.

Lomustine Plus Hydroxyurea Chemotherapy for Primary Intramedullary Spinal Cord Tumor in a Maltese Dog

  • Song, Joong-Hyun;Yu, Do-Hyeon;Hwang, Tae-Sung;Lee, Hee-Chun;An, Su-Jin;Sur, Jung-Hyang;Kim, Young Joo;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.180-183
    • /
    • 2019
  • A 7-year-old, male Maltese dog with a body weight of 2.8 kg was presented with a history of hind limbs ataxia that progressed to tetraparesis over a one-month period. Based on physical and neurological examinations, tetraparesis with concomitant UMN signs, kyphosis and severe neck pain were identified. On MRI scan, we tentatively diagnosed this patient as a primary intramedullary spinal cord tumor. Therapy with lomustine plus hydroxyurea and prednisolone was initiated and the clinical signs rapidly improved. The patient was regularly checked by MRI scan and the range of the mass was gradually reduced to complete remission for 11 months. About 19 months after treatment, the patient showed anemia and hematochezia which suspected as adverse effects of chemotherapy. The condition was getting worse over 2 months and the patient suddenly expired 657 days after initial presentation. On histopathological examination, the spinal cord sample was identified as a neuronal atrophy without evidence of tumor cell.

Acute Osteomyelitis in the Hand Due to Dog Bite Injury: A Report of 3 Cases

  • Lee, Ryun;Lee, Hee Young;Kim, Ji Hyun;Han, Yea Sik;Kim, Dong Chul;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.444-448
    • /
    • 2017
  • As many people keep small dogs as pets, dog bites are common injuries, accounting for approximately 80%-90% of all animal bite injuries. These injuries usually occur on the upper extremities, most commonly on the fingers. Most of these injuries appear as simple lacerations or abrasions of the skin. Common symptoms include inflammatory reactions of the soft tissue, such as pain, swelling, erythema, and cellulitis. However, the complications of small dog bites may include joint or cartilage injuries, including acute osteomyelitis. Once osteomyelitis develops, it is difficult to diagnose since it has a latency period of approximately 2 weeks. Plain radiography, magnetic resonance imaging, and 3-phase bone scans should be performed when acute osteomyelitis is suspected, and broad-spectrum empiric antibiotic treatment should be administered for approximately 8-12 weeks. We report 3 very rare cases of acute osteomyelitis that occurred after a dog bite injury.

A Case of Gastric Adenoma in a Maltese Dog (말티즈 견에서 발생한 위 선종 증례)

  • Eom, Na-Young;Lee, Hee-Chun;Lee, Seung-Yong;Jang, Hyo-Mi;Sur, Jung-Hyang;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.370-373
    • /
    • 2015
  • A 10-year-old, intact female, Maltese dog was presented with a two weeks history of vomiting, anorexia and weight loss. Hematologic analysis revealed mild leukocytosis and increased liver enzyme. Gaseous dilation of small intestine and hyperechoic nodules of hepatic lobes were revealed on the imaging studies. Liver biopsy was performed through laparotomy and histopathologic results revealed liver cirrhosis with precancerous lesions. Two days later, endoscopy was performed and histopathologic results of the specimens taken by endoscopic biopsy showed gastric adenoma. The gastric surgery was not performed by the owner's request. The patient died after 60 days of diagnosis of gastric adenoma. This case describes clinical features, imaging studies, endoscopic features and histopathologic characteristics of gastric adenoma in a Maltese dog.

Optimization of Dual Layer Phoswich Detector for Small Animal PET using Monte Carlo Simulation

  • Y.H. Chung;Park, Y.;G. Cho;Y.S. Choe;Lee, K.H.;Kim, S.E.;Kim, B.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.44-44
    • /
    • 2003
  • As a basic measurement tool in the areas of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly. An ideal small animal PET should have high sensitivity and high and uniform resolution across the field of view to achieve high image quality. However, the combination of long narrow pixellated crystal array and small ring diameter of small animal PET leads to the degradation of spatial resolution for the source located at off center. This degradation of resolution can be improved by determining the depth of interaction (DOI) in the crystal and by taking into account the information in sorting the coincident events. Among a number of 001 identification schemes, dual layer phsowich detector has been widely investigated by many research groups due to its practicability and effectiveness on extracting DOI information. However, the effects of each crystal length composing dual layer phoswich detector on DOI measurements and image qualities were not fully characterized. In order to minimize the DOI effect, the length of each layer of phoswich detector should be optimized. The aim of this study was to perform simulations using a simulation tool, GATE to design the optimum lengths of crystals composing a dual layer phoswich detector. The simulated small PET system employed LSO front layer LuYAP back layer phoswich detector modules and the module consisted of 8${\times}$8 arrays of dual layer crystals with 2 mm ${\times}$ 2 mm sensitive area coupled to a Hamamatsu R7600 00 M64 PSPMT. Sensitivities and variation of radial resolutions were simulated by varying the length of LSO front layer from 0 to 10 mm while the total length (LSO + LuYAP) was fixed to 20 mm for 10 cm diameter ring scanner. The radial resolution uniformity was markedly improved by using DOI information. There existed the optimal lengths of crystal layers to minimize the variation of radial resolutions. In 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm over 8 cm FOV while the sensitivity was higher than 7.4% for LSO 5 mm : LuYAP 15 mm phoswich detector. In this study, the optimal length of dual layer phoswich detector was derived to achieve high and uniform radial resolution.

  • PDF