• 제목/요약/키워드: slump test

검색결과 409건 처리시간 0.025초

Belite 시멘트를 이용한 고성능 콘크리트의 철근 부착성능 실험연구 (An experimental study on Bond strength of Reinforcing steel to High-performance Concrete using Belite Cement)

  • 조필규;김상준;강지훈;김영식;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.408-415
    • /
    • 1997
  • Bond strength of reinforcing bar to high-performance concrete using Belite cement is explored using beam end test specimen. The key parameters for the bond test are slump of concrete, top bar effect, and strength of concrete in addition to concrete covers. Specimen failed in the typical brittle bond failure splitting the concrete cover as the wedging action. The test results show that for the group with portland cement I using superplasticizer additional slump does not decrease the bond strength of the top bar is less than bond strength of bottom bar, but the top bar factor satisfy the modification factor for top reinforcement. The result also show that bond strength is function of square root of concrete compressive strength and cover thickness. More detailed evaluation will be conducted from the test specimen with high strength concrete using the belite cement.

  • PDF

실리카흄 및 플라이애쉬의 치환율 변화에 따른 초고강도 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on the Properties of Ultra High Strength Concrete for Replacement of Silica Fume & Fly Ash)

  • 윤기원;조병영;한천구;반호용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.157-160
    • /
    • 1994
  • Recently, many studies on the ultra high strength concrete are performed in our country. so, this study is aimed for analyzing the effects for replacement of silica fume and fly ash. As results, slump, slump flow and compressive strength is showed the high values in replacement silica fume. Tensile strength ratio is 1/17 and bending strength ratio is 1/6 for compressive, there are results of the test.

  • PDF

폴리프로필렌섬유 보람 고유동 콘크리트의 공학적 특성 (Engineering Property of Polyprofilene Fiber Reinforced High Flowable Concrete)

  • 노경희;김영익;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.185-188
    • /
    • 2002
  • This study is performed to examine the engineering properties of polyprofilene fiber reinforced high flowable concrete. For the estimation of the flow ability and filling ability, the slump flow, box height difference and L-shape filling appearence are measured and compared. The test result shows that the slump flow and L-shape filling appearence is decreased with increase containing polyprofilene fiber and box height difference is increased with increase containing polyprofilene fiber. Also, compressive strength is decreased with increase containing polyprofilene fiber.

  • PDF

역타공법 적용을 위한 콘크리트 경시변화 특성 연구 (A Study of Elapsed Time Change on Concrete for Top-Down Method)

  • 정근호;이종균;박선길;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.487-492
    • /
    • 1999
  • The purpose of this study to find the mixture of concrete for Top-Down method. Throughout test of elapsed time change and L-type flow, it was proposed basic performance and level of top-down method concrete. When change as to elapsed time is considered, so series of F10 added 10% S.P satisfied slump and demanded flow (60$\pm$5cm), and L-type slump, L-type flow satisfied liquidity, it can be considered basic mixture of designed actual frame later.

  • PDF

고강도, 고유동 Belite 콘크리트의 부착성능 (Bond Strength of Reinforcing Steel to High Strength, High Flow Belite Concrete)

  • 김상준;조필규;이세웅;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.653-660
    • /
    • 1998
  • Bond strength of reinforcing bar to high-performance concrete using belite cement is explored using beam end test specimen. The key parameters for the bond test are slump of concrete, top bar effect, and strength of concrete in addition to concrete covers. Specimen failed in the typical brittle bond failure splitting the concrete cover as the wedging action. The test results show that the specimens with belire cement concrete show higher bond strength than those with portland cement concrete. Bond strength of the top bar is less than bond strength of bottom bar, but the top bar factor satisfies the modification factor for top reinforcement. The results also show that the bond strength is function of the square root of concrete compressive strength and cover thickness. The recently developed high-strength and high-slump concrete with belite cement performs well in terms of bond strength to reinforcing steel.

  • PDF

콘크리트와 이형철근의 계면 부착성능 : 상단철근 및 에폭시도막철근 효과 (A Study on Interfacial Bond Capacity of Deformed Bars to Concrete : Top Bars and Epoxy-Coated Bars)

  • 강석원;홍건호;정일영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.204-209
    • /
    • 1995
  • The influence of the interfacial properties on the bond capacity of reinforcing bars to concrete is studied in this paper. In this study, the deterioration of the interfacial bond capacity when top-cast bars or epoxy-coated bars are used is examined. The effect of such variables on bond capacity in reinforced concrete is studied by experiment which use beam-end specimens. The main objective of this study is that comparing the test results and the requirements in ACI 318-89 code. the verification of the factor in ACI code is also presented in this paper. The results of the test show that "top bar effect" is considerably affected by the slump of fresh concrete, so the influence of slump shoud be taken into account for top bar effect factor in code. Test results also shows that the bond-slip curve of the epoxy-caoted bars is similiar to that of the uncoated and bond strength is reduced about 15% and that coating thickness seems to influence the bond strength deterioration.rioration.

  • PDF

CGS 공법에 의한 지반침하억제 사례연구 (A Case Study on the Plan for Settlement Restraint by CGS)

  • 천병식;여유현;김우종;황성식;김우철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.611-618
    • /
    • 2002
  • In this study the CGS as an injection method by low slump mortar was performed the pilot test to confirm the applicability of this method and the effectiveness of settlement restraint. From the results, there has been concluded the construction control standard such as an institutional diameter, space, depth, injection materials, Infection pressure etc. Also, there has been estimated the ground improvement effectiveness which has resulted from the field investigation and consolidation test etc. From the results, in the adjacent ground the CGS, generally, has been confirmed to in-crease ground strength to improve the consolidation characteristic obtained from the field investigation and consolidation test. Especially, the CGS which performed the larger stiffness to the ground has been concluded that the settlement restraint to the ground complicates the ground effect which Increases the bearing capacity and stress assignment. So, the CGS can be considered as an effective method to increase the bearing capacity as well as the settlement restraint of soft ground.

  • PDF

고성능 콘크리트의 실용화를 위한 시공특성에 관한 실험적 연구 (An Experimental Study on Workability for Practical Use of High-Performance Concrete)

  • 양근혁;이영호
    • 한국건축시공학회지
    • /
    • 제3권1호
    • /
    • pp.139-146
    • /
    • 2003
  • The special requirements of high-performance concrete(HPC) could be enhanced property over others such as compressive strength, durability, and construction practices. In order to satisfy these requirements a series of laboratory trial mixes and following mock-up test of reinforced concrete wall at field were performed in this study. The objective of this study was to quantitatively evaluate the workability, compressive strength, and the increased heat of hydration caused by the increase of the specific weight of cement according to various variables. Six example series designed about a minimum compressive strength of 500kgf/$\textrm{cm}^2$ at 28 days, and an approximately slump and slump flow of 25cm and 60cm respectively were tested. The selection process of the specific weight of water and the percentage of fly-ash transposition determined to be most suitable for the production of HPC is presented in the following paper.

경량골재의 표면처리에 따른 콘크리트의 탄산화 저항성에 관한 실험적 연구 (An Experimental Study on Carbonation Resistance of Concrete Depending on Surface Treatment of Lightweight Aggregates)

  • 엄인혁;온재훈;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.89-91
    • /
    • 2012
  • The purpose of this study is to investigate the mechanical property and carbonation resistance of concretes using surface treated lightweight aggregate. In order to evaluate mechanical property and carbonation resistance, slump, compressive strength, and carbonation depth are tested. Slump of concretes using surface treated lightweight aggregate measured 120~125mm, which are lower than slump of NWAC. Compared to compressive strength of NWAC, compressive strength of concretes using surface treated lightweight aggregate showed a level of 82.8~95.9%. In carbonation resistance test, carbonation depth of concretes using surface treated lightweight aggregate measured 10.2~11.3mm, which are lower than carbonation depth of NWAC. As a result, it is found that compressive strength is decreased slightly but carbonation resistance is improved, in case of using surface treated lightweight aggregate.

  • PDF

부순모래의 입자특성이 콘크리트의 품질에 미치는 영향 (Influence of Particle Properties of Crushed Sand on the Qualities of Concrete)

  • 유승엽;손유신;이승훈;이건철;윤기원;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.89-92
    • /
    • 2005
  • This study investigates influence of particle properties of crushed sand on the duality of concrete. The test shows that an increase of fineness modulus(FM) resulted in high slump and air contents, while compressive strength decreased due to decreased adhesion with reduction of surface area. As grain shape become rounder, the slump of concrete increased, due to reduction of internal friction, and increased air contents. The reduction of adhesion by abrasion of surface declined compressive strength during the process of manufacturing crushed sand. Increase of powder contents decreased slump and it also decreased air contents due to the effect of filling air void. In addition. using powder contents increased compressive strength, but could not find any difference of bleeding and tensile strength with particle properties.

  • PDF