• Title/Summary/Keyword: slow wave

Search Result 272, Processing Time 0.025 seconds

Breaking Wave Generation in the Laboratory (실험실에서의 쇄파발생)

  • Cho, Won-Chul;Michael Bruno
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.3
    • /
    • pp.178-186
    • /
    • 1992
  • An experimental study of deep-water breaking waves are performed by superposition of different wave frequencies, faster waves overtaking slow waves at a certain location. Large spilling and plunging breaking waves are generated near the expected breaking location. Wave steepness in spilling and plunging breakers significantly increases as the breaking point is approached and then decreases after breaking. Larger growth rate of the wave steepness in vigorous plunging breaking is observed. The fundamental wave frequencies in a wave group are dominant through the wave evolution, even in an intense plunging breaking event.

  • PDF

A Study on the Wave Drift Damping of a Moored Ship in Waves (파랑중 계류된 선박의 표류감쇠에 관한 연구)

  • 이호영;박홍식;신현경
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2000
  • As the offshore oil fields are moved to the deep ocean, the oil production system of FPSO(Floating Production Storage and Offloading System) Type are constructed frequently these days. So, it is very important to estimate the drift motion and damping effects due to the drift motion simultaneously. The components of slow drift motion damping consist of viscous, wave radiation effect and wave drift damping. It is needed to estimate the wave drift damping more accurately than others. The wave drift damping signifies the time-rate of mean wave drift force on oscillating ship or ocean structure which constant speed. In order to calculate this, the 3-Dimensional panel method is employed with the translating and pulsating Green function in the frequency domain. The calculation is carried out for a Series 60 ($C_B$/=0.7) and the results are compared with other numerical ones.

  • PDF

Nonlinear Motion Analysis of FPSO with Turret Mooring System (터렛계류된 FPSO의 비선형 운동 해석)

  • Lim, Choon-Gyu;Lee, Ho-Young
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.161-166
    • /
    • 2002
  • As offshore oil fields move towards the deep ocean, the oil production systems such as FPSO are being built these days. Generally, the FPSO is moored by turret mooring lines to keep the position of FPSO. Thus nonlinear motion analysis of moored FPSO must be carried out in the initial design stage because sea environments affect motion of it. In this paper the mathematical model is based on the slow motion maneuvering equations in the horizontal plane considering wave, current and wind forces. The direct integration method is employed to estimate wave loads. The current forces are calculated by using mathematical model of MMG. The turret mooring forces are quasi-statically evaluated by using the catenary equation. The coefficients of a model for wind forces are calculated from Isherwood's experimental data and the variation of wind speed is estimated by wind spectrum according to the guidelines of API-RP2A. The nonlinear motions of FPSO are simulated under external forces due to wave, current, wind including mooring forces in time domain.

  • PDF

Pressure Wave Propagation in the Discharge Piping with Water Pool

  • Bang Young S.;Seul Kwang W.;Kim In-Goo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.285-294
    • /
    • 2004
  • Pressure wave propagation in the discharge piping with a sparger submerged in a water pool, following the opening of a safety relief valve, is analyzed. To predict the pressure transient behavior, a RELAP5/MOD3 code is used. The applicability of the RELAP5 code and the adequacy of the present modeling scheme are confirmed by simulating the applicable experiment on a water hammer with voiding. As a base case, the modeling scheme was used to calculate the wave propagation inside a vertical pipe with sparger holes and submerged within a water pool. In addition, the effects on wave propagation of geometric factors, such as the loss coefficient, the pipe configuration, and the subdivision of sparger pipe, are investigated. The effects of inflow conditions, such as water slug inflow and the slow opening of a safety relief valve are also examined.

The Contractile and Electrical Responses of Guinea-pig's Gastric Smooth Muscle to Serotonin

  • Lee, Sang-Jin;Hwang, Sang-Ik;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.133-146
    • /
    • 1991
  • In order to elucidate systematically the effects of serotonin on gastric motility of guinea-pig, the contractile and electrical responses to serotonin were recorded using four kinds of muscle strips prepared from antral circular, antral longitudinal, fundic circular, and fundic longitudinal muscles. Experiments were performed using various methods including isometric contraction recording, transmural electrical field stimulation, junction potential recording, intracellular microelectrode technique, and partition stimulation method. The results were as follows: 1) The effect of serotonin on spontaneous contractions was inhibitory in the circular muscle strips of the antrum and fundus, while it was excitatory in the longitudinal muscle strips of the antrum and fundus. Serotonin changed mainly phasic contractions of both the circular and longitudinal muscle strips in the antrum, while it changed mainly tonic contractions of both the circular and longitudinal muscle strips in the fundus. 2) On the contractions induced by transmural nerve stimulation, serotonin decreased the amplitude in the circular muscle strips of the antrum, but it increased them in the other three groups of muscle strips(antral longitudinal, fundic circular, and fundic longitudinal). 3) On the contractions induced by direct muscle stimulation, serotonin decreased the amplitude in the circular muscle strips of the antrum and fundus. 4) In the fundic circular muscle strips serotonin potentiated excitatory junction potentials (EJPs), and in the antral circular muscle strips it evoked EJPs after inhibitory junction potentials(IJPS). 5) In the antral circular muscle strips serotonin did not affect the slow wave even at the disappearance of spontaneous contractions. On the contrary it increased the amplitude of the slow wave, when the spike component was potentiated and the second component was inhibited. 6) In the antral circular muscle strips the membrane potential was slightly hyperpolarized, but the membrane resistance was not changed. From the above results following conclusions could be made. 1) Serotonin inhibits spontaneous contractions of the circular muscle layer and it increases those of the longitudinal one, irrespective of the gastric region. 2) In the guinea-pig stomach there exists a serotoninergic facilitatory neuromodulation system which exerts its effect on cholinergically mediated contraction. 3) The excitation-contraction decoupling was observed in the effect of serotonin.

  • PDF

Transmission Line Parameter Extraction and Signal Integrity Verification of VLSI Interconnects Under Silicon Substrate Effect (실리콘 기판 효과를 고려한 VLSI 인터컨넥트의 전송선 파라미터 추출 및 시그널 인테그러티 검증)

  • 유한종;어영선
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.3
    • /
    • pp.26-34
    • /
    • 1999
  • A new silicon-based IC interconnect transmission line parameter extraction methodology is presented and experimentally examined. Unlike the PCB or MCM interconnects, a dominant energy propagation mode in the silicon-based IC interconnects is not quasi-TEM but slow wave mode(SWM). The transmission line parameters are extracted taking the silicon substrate effect (i.e., slow wave mode) into account. The capacitances are calculated considering silicon substrate surface as a ground. Whereas the inductances are calculated by using an effective dielectric constant. In order to verify the proposed method, test patterns were designed. Experimental data have agreement within 10%. Further, crosstalk noise simulation shows excellent agreements with the measurements which are performed with high-speed time domain measurement ( i.e., TDR/TDT measurements) for test pattern, while RC model or RLC model without silicon substrate effect show about 20~25% underestimation error.

  • PDF

A Study on a Meander line employing Periodic Patterned Ground Structure on GaAs MMIC (GaAs MMIC 상에서 주기적 접지구조를 가지는 미앤더 선로에 관한 연구)

  • Jung, Bo-Ra;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.325-331
    • /
    • 2010
  • In this study, highly miniaturized short-wavelength meander line employing eriodically patterned ground structure (PPGS) was developed for application to miniaturized on-chip passive component on GaAs MMIC (monolithic microwave integrated circuit). The meander line employing PPGS showed shorter wavelength and slow-wave characteristic compared with conventional meander line. The wavelength of the meander line employing PPGS structure was 17 % of the conventional meander line on GaAs MMIC. Due to its slow-wave structure, the meander line employing PPGS exhibited large propagation constant than conventional meander line, which resulted in larger phase shift and shunt inductance value. Above results indicate that the meander line employing PPGS is a promising candidate for application to a development of miniaturized on-chip RF components as well as inductor with a high inductance value on GaAs MMIC.

Effect of Yijin-tang on Gastric Motility in STZ-Induced Diabetic Rats (이진탕(二陳湯)이 STZ 유발(誘發) 당뇨병(糖尿病) 흰쥐의 위(胃) 운동성(運動性)에 미치는 영향(影響))

  • Hur, Won-Young;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • Backgrounds & Objectives : The aims of this study were to observe how morphology was changed and whether gastric motility was impaired in streptozotocin(STZ)-induced diabetic rats(DR), and whether Yijin-tang(YJT) was able to restore their impaired gastric motility. Methods : We investigated the change of body weight, feed intake and blood glucose between normal rats (NR) and DR for 12 weeks after induction of diabetes. At the time of 12 weeks after induction of diabetes, gastric surface area, gastric slow wave and gastric emptying rate were measured. Results : Decreased body weight, increased feed intake and increased gastric surface area were observed in DR, compared with NR. The percentage of normogastria decreased but that of bradygastria increased in DR, compared with NR. YJT 90mg/kg had no effect on the correction of gastric slow wave. YJT 90mg/kg and 270mg/kg had a significant effect on improvement of gastric emptying, more than normal saline (NS) in both NR and DR but the gastric emptying rate of DR was significantly lower than that of NR when YJT 90mg/kg and YJT 270mg/kg were administered. Conclusions : We can expect that administration of YJT would be effective on the improvement of gastric emptying and upper gastrointestinal symptoms as a juvantia.

  • PDF

Evaluation of Cranial Sacral Therapy (CST) Based Pillow on Sleep Induction Using the Electroencephalogram (EEG) (뇌파를 이용한 두개천골요법 기반 베개의 수면유도 효과 검증)

  • Kwon, Hyeok Chan;Phyo, Jung Bin;Park, Yong Gil;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2018
  • The purpose of this study was to investigate the effect of a pillow simulated with cranial sacral therapy (CST) on sleep induction using electroencephalography (EEG). This study included 12 voluntary participants divided into experimental group (CST group) and control group (Non-CST group) to observe EEG changes. The position of the electrode for EEG measurement consists of 8 channels electrodes (Fp1, Fp2, F3, F4, T3, T4, P3 and P4). In this study, we measured the fall asleep time, change of brain activity and sleep wave ratio using EEG wave (${\delta}$, ${\theta}$, ${\alpha}$, ${\beta}$ and ${\gamma}$). As a result, the mean fall asleep time of the experimental group was shorter than that of the control group significantly (p < 0.001). Also in comparison with the control group, both the delta (d) and theta (q) wave corresponding to the slow waves showed a larger increase and the alpha (a) wave showed a larger decrease significantly. The slow waves of experimental group showed a higher rate of significant increase than the control group (p < 0.001). Therefore this study showed that pillow based on CST had an effective in improving sleep induction and quality.