• Title/Summary/Keyword: slip load

Search Result 518, Processing Time 0.025 seconds

A Study on Performance Evaluation of New Asphalt Surface Reinforcement Method (ASRM) for Preventive Maintenance (예방적 유지보수를 위한 아스팔트 표면강화공법의 실내 성능 평가)

  • Kim, Kyungnam;Jo, Shin Haeng;Kim, Nakseok;Lee, Doosung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.311-317
    • /
    • 2018
  • The new asphalt surface reinforcement method (ASRM) is one of the preventive maintenance methods in asphalt concrete pavements. The adhesion performance of new ASRM satisfied the standard of non-slip pavement and bridge waterproofing materials. As a results of durability tests (as wheel load, rolling bottle and UV resistance test), the new ASRM showed sufficient resistance to traffic and environmental loads. The waterproof and chemical resistance tests of new ASRM were conducted to evaluate whether the pavement could be protected from water and chemicals and the performances of new ASRM were satisfactory. Furthermore, the new ASRM demonstrated some rejuvenation effects due to its toughness increases in recycled asphalt concrete mixture by 5% compared to the conventional hot mix asphalt mixture using reclaimed asphalt pavement. In conclusion, the new ASRM was evaluated to protect the asphalt concrete pavement and increase the lifetime.

The Dynamic Performance Analysis of Foil Journal Bearings Considering Coulomb Friction: Rotating Unbalance Response (마찰을 고려한 포일저널베어링의 동특성해석: 회전불균형 응답)

  • Kim, Kyung-Woong;Lee, Dong-Hyun;Kim, Young-Cheol
    • Tribology and Lubricants
    • /
    • v.23 no.5
    • /
    • pp.219-227
    • /
    • 2007
  • The dynamic performance of air foil bearings relies on a coupling between a thin air film and an elastic foil structure. A number of successful analytical techniques to predict dynamic performance have been developed. However, the evaluation of its dynamic characteristic is still not enough because of the mechanical complexity of the foil structure and strong nonlinear behavior of friction force. This work presents a nonlinear transient analysis method to predict dynamic performance of foil bearings. In this method, time dependent Reynolds equation is used to calculate pressure distribution and a finite element method is used to model the bump foil structure. The analysis is treated with a direct implicit integration technique that can handle nonlinear problems and the stick-slip algorithm is used to consider friction force. Using this method the response to the mass unbalance excitation is investigated for various design parameters and operating conditions. The results of analysis show that foil bearing is very effective on the restriction of vibration at the resonance frequency compared to the rigid surface bearings and the effectiveness depends on the operating conditions, static load and a amount of mass unbalance. In addition, there exist optimum values of friction coefficient, bump foil stiffness and number of circumferential slit with regards to minimizing dynamic response at the resonance frequency. These optimum values are system dependent.

Whole Mount Preparation of Primary Cultured Neuron for HVEM Observation (배양된 시경세포 관찰을 위한 초고압전자현미경 홀마운트 시료제작기법)

  • Kim, Hyun-Wook;Hong, Soon-Taek;Oh, Seung-Hak;Park, Chang-Hyun;Kim, Hyun;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.41 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • High-voltage electron microscope (HVEM) has higher resolution and penetration power than conventional transmission electron microscope that could be load thick specimen. Some researchers have taken this advantage of HVEM to explore 3-dimensional configuration of the biological structures including tissue and cells. Whole mount preparations has been employed to study some cell lines and primary culture cells. In this study, we would like to introduce useful whole mount preparation method for neuronal studies. The plastic coverslips were punched, covered by formvar membrane and coated with carbon. The neurons obtained embryonic 18 rat hippocampus were seeded on the prepared cover slip. The coverslips were fixed, dried in freeze drier and kept in a descicator until HVEM observation. We could observe detailed neuronal structures such as soma, dendrite and spine under HVEM without conventional thin section and heavy metal stain. The anaglyphic image based on stereo paired image ($-8^{\circ},+8^{\circ}$) provides three dimensional perception of the neuronal dendrites and their spines. This method could be applied to sophisticated analysis of dendritic spine under the various experimental conditions.

The Prediction of Debonding Strength on the Reinforced Concrete Beams Strengthened with fiber Reinforced Polymer (섬유복합체로 휨보강된 RC보의 박리하중 예측에 관한 연구)

  • Hong Geon-Ho;Shin Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.903-910
    • /
    • 2005
  • In recent years, fiber reinforced polymer(FRP) plates have shown a great promise as an alternative to steel plates for reinforced concrete beam rehabilitation. Reinforced concrete beams strengthened with externally bonded FRP sheets to the tension face can exhibit ultimate flexural strengths several times greater than their original strength if their bond strength is enough. Debonding failure, however, may occur before the strengthened beam can achieve its enhanced flexural strength. The purpose of this paper is to investigate the debonding failure strength of FRP-strengthened reinforced concrete beams. An analytical procedure for calculating debonding load between concrete and strengthening FRP is presented. Based on the local bond stress-slip relationship in the previous studies, uniform bond stress is assumed on the effective bond length. The analytical expressions are developed from linear elastic theory and statistical analyses of experimantal results reported in the literature. The proposed method is verified by comparisons with experimental results reported in the previous researches.

Ultimate Behavior of High-Tension Bolted Joints Considering Plate Thickness and Bolt Size (판 두께와 볼트 크기를 고려한 고장력 볼트 이음부의 극한 거동)

  • Kim, Sung-Bo;Choi, Jong-Kyoung;Heo, In-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.515-524
    • /
    • 2008
  • The ultimate behavior of high-tension bolted joints with various plate thickness and bolt size is investigated using nonlinear F.E. analysis and experimental study. The relation with sliding load, bolt deformation, and failure modes are presented based on plate thickness and bolt size. Three kinds of the bolt diameter(M20, M22, M24) and five types of the steel plates (l2mm, 16mm, 20mm, 30mm, 40mm) are considered for the ultimate behavior of the bolted joints. The numerical model, constructed by commercial F.E. program, ABAQUS, of ultimate behavior of bolted joints is introduced and verified by experimental results. The force-displacement and force-axial strain relations are measured and compared with the results by 3D finite element analysis.

Numerical analysis of channel connectors under fire and a comparison of performance with different types of shear connectors subjected to fire

  • Shahabi, S.E.M.;Ramli Sulong, N.H.;Shariati, M.;Mohammadhassani, M.;Shah, S.N.R.
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.651-669
    • /
    • 2016
  • The behavior of shear connectors plays a significant role in maintaining the required strength of a composite beam in normal and hazardous conditions. Various types of shear connectors are available and being utilized in the construction industry according to their use. Channel connectors are a suitable replacement for conventional shear connectors. These connectors have been tested under different types of loading at ambient temperature; however, the behavior of these connectors at elevated temperatures has not been studied. This investigation proposes a numerical analysis approach to estimate the behavior of channel connectors under fire and compare it with the numerical analysis performed in headed stud and Perfobond shear connectors subjected to fire. This paper first reviews the mechanism of various types of shear connectors and then proposes a non-linear thermo-mechanical finite element (FE) model of channel shear connectors embedded in high-strength concrete (HSC) subjected to fire. Initially, an accurate nonlinear FE model of the specimens tested at ambient temperature was developed to investigate the strength of the channel-type connectors embedded in an HSC slab. The outcomes were verified with the experimental study performed on the testing of channel connectors at ambient temperature by Shariati et al. (2012). The FE model at ambient temperature was extended to identify the behavior of channel connectors subjected to fire. A comparative study is performed to evaluate the performance of channel connectors against headed stud and Perfobond shear connectors. The channel connectors were found to be a more economical and easy-to-apply alternative to conventional shear connectors.

Transformation Behavior of Ti-(45-x)Ni-5Cu-xCr (at%) (x = 0.5-2.0) Shape Memory Alloys

  • Im, Yeon-Min;Jeon, Young-Min;Kim, Min-Su;Lee, Yong-Hee;Kim, Min-Kyun;Nam, Tae-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.1
    • /
    • pp.28-31
    • /
    • 2011
  • Transformation behavior and shape memory characteristics of Ti-(45-x)Ni-5Cu-xCr (x=0.5-2.0) alloys have been investigated by means of electrical resistivity measurements, differential scanning calorimetry, X-ray diffraction and thermal cycling tests under constant load. Two-stage B2-B19-B19' transformation occurred in Ti-(45-x)Ni-5Cu-xCr alloys. The B2-B19 transformation was separated clearly from the B19-B19' transformation in Ti-44.0Ni-5Cu-1.0Cr and Ti-43.5Ni-5Cu-1.5Cr alloys. A temperature range where the B19 martensite exists was expanded with increasing Cr content because decreasing rate of Ms (85 K / % Cr) was larger than that of Ms' (17 K / % Cr). Ti-(45-x)Ni-5Cu-xCr alloys were deformed in plastic manner with a fracture strain of 68% ~ 43% depending on Cr content. Substitution of Cr for Ni improves the critical stress for slip deformation in a Ti-45Ni-5Cu alloy due to solid solution hardening.

Characteristics of Flexural Behavior of Composite Section Consisting of Steel Girder with 80MPa High Strength Concrete on Compressive Flange (압축 플랜지에 80MPa급 고강도 콘크리트가 합성된 I형 강거더의 휨거동 특성)

  • Lee, Juwon;Yang, In-Wook;Lim, Eol;Ha, Tae-Yul;Lee, Kwan-Jong
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.455-464
    • /
    • 2017
  • Static loading test was performed on a composite girder with an I-shaped steel girder and SUPER concrete on the top of the steel in order to evaluate flexural behavior characteristics. Total length of the test specimen was 25m long and the depth was 786mm including compressive concrete section('casing' hereafter) with 80MPa strength. 4-point loading on simply-supported beam was applied up to 2,010kN. Results showed that yield strength at tensile steel was 2.7 times greater than service load and the ratio of ductility was 1.481. No cracks were found on the casing surface and the relative slip between different sections was insignificant.

Slope Stability Analysis Considering Reinforcing Effects of Geosynthetics (토목섬유의 보강효과를 고려한 사면안정해석)

  • Kim, Kyeong-Mo;Kim, Hong-Tack;Lee, Hyung-Kyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.1
    • /
    • pp.73-82
    • /
    • 2005
  • Generally, to evaluate a slope stability of the geosynthetic reinforced soil slope, the modified version of limit equilibrium method can be used. In most cases, resisting effects of reinforcement are dealt with considering an increased shear strength on the potential slip surface. However, it is not clear that the methods satisfy all three equilibrium equations. In this study, the new slope stability analysis method in which not only reinforcing effects of geosynthetics can be considered but also all three equilibrium equation can be satisfied is proposed. A number of illustrative examples, including published load test of large-scale reinforced retaining wall and centrifuge model tests on the geotextile reinforced soil slopes, are also analyzed. As a result, it is shown that the newly suggested method produces a relatively accurate factor of safety.

  • PDF

Experimental and numerical study on static behavior of grouped large-headed studs embedded in UHPC

  • Hu, Yuqing;Zhao, Guotang;He, Zhiqi;Qi, Jianan;Wang, Jingquan
    • Steel and Composite Structures
    • /
    • v.36 no.1
    • /
    • pp.103-118
    • /
    • 2020
  • The static behavior of grouped large-headed studs (d = 30 mm) embedded in ultra-high performance concrete (UHPC) was investigated by conducting push-out tests and numerical analysis. In the push-out test, no splitting cracks were found in the UHPC slab, and the shank failure control the shear capacity, indicating the large-headed stud matches well with the mechanical properties of UHPC. Besides, it is found that the shear resistance of the stud embedded in UHPC is 11.4% higher than that embedded in normal strength concrete, indicating that the shear resistance was improved. Regarding the numerical analysis, the parametric study was conducted to investigate the influence of the concrete strength, aspect ratio of stud, stud diameter, and the spacing of stud in the direction of shear force on the shear performance of the large-headed stud. It is found that the stud diameter and stud spacing have an obvious influence on the shear resistance. Based on the test and numerical analysis results, a formula was established to predict the load-slip relationship. The comparison indicates that the predicted results agree well with the test results. To accurately predict the shear resistance of the stud embedded in UHPC, a design equation for shear strength is proposed. The ratio of the calculation results to the test results is 0.99.