• Title/Summary/Keyword: slip critical connections

Search Result 13, Processing Time 0.018 seconds

A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts (토크전단형 고력볼트의 토크계수 변동에 따른 체결축력 확보방안에 관한 연구)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.8-16
    • /
    • 2014
  • Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.

Estimation on clamping load of high strength bolts considering various environment conditions

  • Nah, Hwan-Seon;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • Of high strength bolts, the torque shear type bolt is known to be clamped normally when pin-tails are broken. Sometimes the clamping loads on slip critical connections considerably fluctuate from the required tension due to variation of torque coefficient. This is why the viscosity of lubricant affects the torque coefficient by temperature. In this study, the clamping tests of high strength bolts were performed independently at laboratory conditions and at outdoor environment. The temperatures of outdoor environment candidates were ranged from $-11^{\circ}C$ to $34^{\circ}C$ for six years. The temperature at laboratory condition was composed from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. At outdoor environment conditions, the clamping load of high strength bolt was varied from 159 to 210 kN and the torque value was varied from 405 to 556 Nm. The torque coefficients at outdoor environment were calculated from 0.126 to 0.158 when tensions were measured from 179 to 192 kN by using tension meter. The torque coefficients at outdoor environment conditions were analyzed as the range from 0.118 to 0.152. From these tests, the diverse equations of torque coefficient, tension dependent to temperature can be acquired by statistic regressive analysis. The variable of torque coefficient at laboratory conditions is 0.13% per each $1^{\circ}C$ when it reaches 2.73% per each $1^{\circ}C$ at outdoor environment conditions. When the results at laboratory conditions and at outdoor environment were combined to get the revised equations, the change in torque coefficient was modified as 0.2% per each $1^{\circ}C$ and the increment of tension was adjusted as 1.89 % per each $1^{\circ}C$.

Evaluation on Clamping force of High Strength Bolts By Temperature Parameter (온도변수에 따른 고력볼트 체결력 평가)

  • Nah, Hwan Seon;Lee, Hyeon Ju;Kim, Kang Seok;Kim, Jin Ho;Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.399-407
    • /
    • 2008
  • The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on temperature variables despite the break of the pin tail. In this study, the tension of torque shear bolts were compared with two types of high-strength hexagon bolts by temperature parameters from ${-10^{\circ}C}$ to ${50^{\circ}C}$. Torque shear bolts showed that the average clamping force increased to 20kN as the temperature increased. In case of galvanized high-strength hexagon bolts, the average clamping forces at $0^{\circ}C$, $20^{\circ}C$, $50^{\circ}C$ were recorded over standard bolt tension, 178kN, and the worst standard deviation was 50kN. In case of high-strength hexagon bolts, ave rage clamping forces increased as the temperature went up, and the worst standard deviation was 33kN lower than that of galvanized high-strength hexagon bolts. As for the turn-of-the-nut method, at nut rotation of ${90^{\circ}}$, two types of high-strength hexagon bolts did not met the intended design bolt in tension, 162kN.it is neccessary to re-evaluate the range of turn of nut, ${120^{\circ}{\pm}30^{\circ}}$.